Brinkmann SFC1520 Series Operating Instructions Manual Download Page 2

BRINKMANN-Cutter pumps SFC1520…3000

 

 

 
BE3185 

Edition

 11/2019 

2

 

Brinkmann Cutter pumps of the series SFC15

20…3000

 

Contents  

1

 

Indication to the manual .................................... 2

 

2

 

Description of product........................................ 2

 

3

 

Safety instructions ............................................. 4

 

4

 

Transport and storage ....................................... 5

 

5

 

Installation and Connection ............................... 5

 

6

 

Start up / Shut down .......................................... 7

 

7

 

Operation ........................................................... 7

 

8

 

Servicing and Maintenance ............................... 8

 

  9

 

Trouble shooter’s guide ..................................... 9

 

10

 

Spare part ........................................................ 10

 

11

 

Repair Instructions / Replacing shaft clamps 

and shafts ........................................................ 12

 

12

 

Disposal ........................................................... 13

 

13

 

EC declaration of conformity ............................ 14

 

 

Indication to the manual 

This operating manual gives basic instructions 

which are to be observed during installation, op-

eration and maintenance of the pump. It is there-

fore imperative that this manual be read by the 

responsible personnel and operator prior to as-

sembly and commissioning. It is always to be 

kept available at the installation site. 

1.1 

Identification of safety instructions 
in the operating manual 

Safety instructions given in this manual non-com-

pliance with which would affect 

safety

 are identi-

fied by the following symbol: 

 

Safety sign according with ISO  

                3864 – B.3.1 
or where 

electrical safety

 is involved, with: 

 

Safety sign according with ISO  

                3864 – B.3.6

 

The signal word 

WARNING

 indicates a hazard-

ous situation which, if not avoided, could result in 

death or serious personal injury. 
The signal word 

CAUTION

 

i

ndicates a hazardous 

situation which, if not avoided, could result in mi-

nor or moderate personal injury. 
The signal word 

ATTENTION

 indicates a hazard-

ous situation which, if not avoided,

 

may cause a 

risk to the machine and it’s function. 

Description of product 

2.1 

General description of the pump 

Pumps of the series SFC are one-stage rotary 

pumps. The impellers are fixed on the driving 

shaft extension. The pump shaft and motor shaft 

are interconnected by means of a shaft clamp. 
The cutting unit is cutting the chips and the semi-

open impeller with its large clearances allows to 

pump the particles along with the coolant fluid 

from the machine back to the filter. The SFC 

pumps are capable of handling chip to coolant ra-

tios of up to 1.5% by weight. 
Pump and motor form a compact and space-sav-

ing unit. 
Vertically mounted pumps are equipped with a 

mounting flange. The pump end immerses into 

the tank and the motor extends vertically above 

the tank. 

2.2 

Intended use 

The cutter pumps of the series SFC are suited for 

cutting aluminum chips or similar materials and 

for pumping these materials along with the cool-

ant fluid.  
–  Pay attention of the limit of application in  

table 1! 

The cutter pumps are intended for installation in 

machines and cannot be operated alone. 

Summary of Contents for SFC1520 Series

Page 1: ...ion 11 2019 1 BRINKMANN Cutter pumps SFC1520 3000 Brinkmann Pumpen K H Brinkmann GmbH Co KG Friedrichstra e 2 D 58791 Werdohl Tel 49 2392 5006 0 www brinkmannpumps de Fax 49 2392 5006 180 sales brinkm...

Page 2: ...ates a hazard ous situation which if not avoided could result in death or serious personal injury The signal word CAUTION indicates a hazardous situation which if not avoided could result in mi nor or...

Page 3: ...ic viscosity of the medium 45 mm2 s Temperature of me dium 0 80 C Dry running Dry running causes in creased wear and should be avoided During the test of the direc tion of rotation 30 s per missible S...

Page 4: ...the personnel 3 5 Safety instructions relevant for op eration If hot or cold machine components involve hazards they must be guarded against acci dental contact Guards for moving parts e g coupling m...

Page 5: ...age Store pump in dry and protected areas and protect it against penetration of for eign bodies Always store pump above the freezing point 5 Installation and Connection 5 1 Mechanical installation WAR...

Page 6: ...may enter the tank 5 2 Electric wiring WARNING Electric shock All service work must be carried out by quali fied service personnel Pump must be discon nected from the power source and all rotating pa...

Page 7: ...hed on Verify that there is no voltage at the termi nal board Open terminal box and disconnect the power leads Empty out the pump 7 Operation WARNING Risk of injury by uncontrolled start up of the pum...

Page 8: ...ar due to the return flow of chips and additional load on the bearings The SFC pump should be operated in continual operation mode not pulsed mode The pump should transport medium with out chips for 1...

Page 9: ...m repair pump Motor overheats High on off cycling frequency Wrong power supply voltage or cycles Insufficient cooling See above Power supply must correspond with name plate rating Check air flow at mo...

Page 10: ...2 22 Shaft nut 23 Compensation disk 24 Shaft seal 25 O ring 26 Shaft seal SFC1820 50 Pump body 51 Shaft with rotor 52 Shaft seal 53 Intake cover 54 Socket head cap screw with lock DIN 912 55 Washer 56...

Page 11: ...with lock DIN 912 55 Washer 56 Chip breaker 57 Bearing bush 58 Socket head cap screw with lock DIN 7984 59 Inlet cover for SFC2320 60 Socket head cap screw with lock DIN 912 for SFC2320 61 Bushing car...

Page 12: ...WARNING Risk of injury due to sharp edges on pump components i e impeller blades Wear safety gloves WARNING Risk of injury by discharging parts Do not under any circumstances remove the screws on the...

Page 13: ...ew connections Pump Installation Secure pump against fall ing over i e with use of safety straps Reconnect immersion pump as described in point 5 ATTENTION When putting the pump back into use make sur...

Page 14: ...EG die Schutz ziele der Niederspannungsrichtlinie 2014 35 EU eingehalten With respect to potential electrical hazards as stated in appendix No 1 5 1 of the machine guide lines 2006 42 EC all safety p...