Brinkmann SBA141 Operating Instructions Manual Download Page 6

 

BE8140 

Edition 10/2021 

Page 6 of 10 

8  Servicing and Maintenance 

 ATTENTION  

The surface of the motor must be kept free of dirt.  

The motor shaft is spinning in permanently greased 
ball  bearings  (with  special  grease  and  increased 
bearing  play)  and  does  not  require  any  special 
maintenance. 
 

8.1 

Pumps with double mechanical seal (-GD)

 

Pumps  with  double  mechanical  seal  (-GD)  are 
identified  by  the  letters  GLRD  stamped  in  on  the 
motor side of the pump foot and must include an oil 
receiver  with  a  capacity  of  0.24  litres.  Check  this 
through the inspection window. 
Oil  receiver  Castrol  WHITEMOR  WOM14  or 
equivalent oil. 

 

Trouble shooter’s guide 

Fault

 

Cause

 

Remedy

 

Motor does not start, no motor 
noise 

At least two of the power supply 
leads have failed  
 
Overload has tripped 

Check fuses, terminals and supply 
leads . 
 
Inspect overload 

Motor does not start, humming 
noise 

One of the supply leads has failed 
 
Impeller faulty 
Motor bearing faulty 

See above 
 
Replace impeller 
Replace bearing 

Overload trips 

Pump locked up mechanically 
High on/of cycling frequency 

Inspect pump hydraulics 
Check application 

Power consumption is too high 

Wrong direction of rotation of 
impeller 
Lime or other deposits 
mechanical friction 

See above 
 
Clean pump mechanism  
repair pump 

Motor overheats 

High on/off cycling frequency 
Wrong power supply (voltage or 
cycles) 
 
Insufficient cooling 

See above 
Power supply must correspond with 
name plate rating 
 
Check air flow at motor fan 

Pump does not pump 

liquid level too low 
Pump mechanism faulty 
Pipe blocked 

Fill up liquid 
replace pump mechanism 
Clean pipe 

Insufficient flow and pressure 

Wrong direction of rotation of 
impeller  
 
Pump mechanism silted up 
Worn pump mechanism 

Change over two power supply 
leads 
 
Clean pump mechanism  
Replace pump mechanism 

Incorrect flow or pressure 

Wrong power supply (voltage or 
cycles) 

Power supply must correspond with 
name plate rating 

Running noise/Vibration 

Foreign objects in pump end 
Impeller damaged 
Bearing/Bushing broken 

Remove foreign objects 
Replace impeller 
Replace bearing/bushing 

Summary of Contents for SBA141

Page 1: ...e 1 of 10 BRINKMANN Horizontal End Suction Pumps SBA141 143 SBF125 Brinkmann Pumpen K H Brinkmann GmbH Co KG Friedrichstraße 2 D 58791 Werdohl Tel 49 2392 5006 0 www brinkmannpumps de Fax 49 2392 5006 180 sales brinkmannpumps de Subject to change without prior notice Order No BE8140 ENGLISH ...

Page 2: ...his type are one or multi stage centrifu gal inline pumps with a compact design where the impellers are fixed on the driving shaft extension The pump shaft and motor shaft are interconnected by means of a shaft clamp These pumps are fitted out with semi open impellers and a suction screw in order to minimize the risk of cavitations SBA pumps are equipped with a single mechanical seal The SBF Pumps...

Page 3: ... removing the pump exists Proper and secured lifting tools must be used Risk of burns The pump must have cooled down sufficiently prior to commencing any repair maintenance or installa tion 3 4 Qualification and training of operating personnel The personnel responsible for operation mainte nance inspection and assembly must be adequate ly qualified Scope of responsibility and supervision of the pe...

Page 4: ...e Protect the pump against damage when transport ing The pumps may only be transported in a horizontal position and hooks or straps must be attached on the motor and pump end Do not use the pump shaft for connecting any transportation aids such as hooks or straps Pumps must be drained prior to their storage Store pump in dry and protected areas and protect it against penetration of foreign bodies ...

Page 5: ...ed wiring ports ATTENTION When Variable Frequency Drives are used interfer ing signals might occur Non sinus shaped supply voltage from a variable frequency drive might result in elevated motor temperatures 6 Start up Shut down 6 1 Start up ATTENTION Switch off at the mains After connection the electrical wires close the terminal box Briefly start the motor max 30 sec and check the rotation accord...

Page 6: ...ng faulty See above Replace impeller Replace bearing Overload trips Pump locked up mechanically High on of cycling frequency Inspect pump hydraulics Check application Power consumption is too high Wrong direction of rotation of impeller Lime or other deposits mechanical friction See above Clean pump mechanism repair pump Motor overheats High on off cycling frequency Wrong power supply voltage or c...

Page 7: ...1 7 kW DIN 912 17 Socket head cap screw DIN 912 19 Parallel pin DIN 7 22 shim ring 24 Mechanical seal 25 Circlip 26 Shaft seal 1 1 kW and over 27 Oil inspection window for GD 27 Screw plug DIN 908 28 Sealing ring DIN 7603 29 O ring Item Description 30 Shaft seal 31 Compensation disk 1 7 kW 50 Pump body 51 Motor shaft with rotor 52 Connection cover 53 Pump plate with bearing bush SBA142 143 54 Pump...

Page 8: ...te 53 and O ring 67 7 Remove the spacer sleeve 59 Use two screw drivers to push the impeller 55 from the quick shaft 91 Insert the screwdrivers between the impeller 55 and the pump plate 54 8 Remove the Woodruff key 64 from the insert shaft 91 Remove the pump plate 54 and the O ring 67 9 Remove the spacer sleeve 60 and use two screwdrivers to push the impeller 55 from the quick shaft 91 Insert the...

Page 9: ...mp 24 mm for SBA141 SBA142 and SBF125 Use a torque screwdriver to tighten each screw first with 1 3 Nm then with 2 6 Nm and finally with 4 Nm in a clockwise direction again Tighten the shaft clamp 35 mm for SBA143 Use a torque screwdriver to tighten each screw first with 2 Nm then with 3 5 Nm and finally with 5 Nm in a clockwise direction again Repeat the last turn with 5 Nm 3 times 11 Mount the p...

Page 10: ...chinenrichtlinie 2006 42 EG die Schutz ziele der Niederspannungsrichtlinie 2014 35 EU eingehalten With respect to potential electrical hazards as stated in appendix І No 1 5 1 of the machine guide lines 2006 42 EC all safety protection goals are met according to the low voltage guide lines 2014 35 EU Conformément à l annexe I N 1 5 1 de la Directive Machines 2006 42 CE les objectifs de sécurité re...