5.2  Electric wiring 

 

All  service  work  must  be  carried  out  by  quali-
fied  service  personnel.    Pump  must  be  discon-
nected  from  the  power  source  and  all  rotating 
parts  must  stand  still.    Reassure  that  pump  is 
disconnected from power source and cannot be 
switched  on.    Verify  that  there  is  no  voltage  at 
the terminal board! 

According  to  the  European  Standard  EN809  a 
motor  overload  must  be  installed  and  properly  set 
to  the  full  load  amps  stated  on  the  pump  name 
plate. 

It  is  the  responsibility  of  the  machine  operator  to 
decide  whether  or  not  an  additional  emergency 
switch must be installed. 

5.2.1 

Circuit 

 

Tension  voltage  and  frequency  must  correspond 
with the shown specification on the nameplate

.

 

The  pump  must  be  wired  so  that  a  solid  longterm 
electrical  connection  is  ensured.  Establish  a  solid 
ground connection. 

The electrical wiring must be performed accord-
ing  to  the  wiring  diagram  shown  inside  the 
terminal  box  cover.  (Please  see  above  sample 
wiring diagrams) 

Wiring diagram e.g.

 

 

There  may  be  no  foreign  objects  such  as  dirt, 
particles or humidity inside the terminal board. 

Mount  terminal  board  cover  to  motor  tight  against 
dust  and  humidity  and  close  up  all  unused  wiring 
ports. 

 ATTENTION  

When Variable Frequency Drives are used interfer-
ing signals might occur. 
Non-sinus shaped supply voltage from a variable 
frequency drive might result in elevated motor 
temperatures. 

6  Start up / Shut down 

6.1  Start up 

 ATTENTION  

Switch off at the mains. 
After connection the electrical wires, close the 
terminal box. Briefly start the motor (max. 30 sec.) 
and check the rotation according to the arrow on 
the top of the motor. 
If  the  direction  is  incorrect  change  over  two  of  the 
power leads. 

6.2  Shut down  

All  service  work  must  be  carried  out  by  qualified 
service  personnel.  Pump  must  be  disconnected 
from  the  power  source  and  all  rotating  parts  must 
stand  still.  Reassure  that  pump  is  disconnected 
from  power  source  and  cannot  be  switched  on. 
Verify that there is no voltage at the terminal board! 
Open terminal box and disconnect the power leads. 
Empty out the pump. 

7  Operation 

Liquid level 

These  pumps  are  not  self-priming  and  must  be 
gravity fed. 
Possible  leakage  must  be  drained  away  so  as  to 
prevent any risk to persons or the environment. 

 

 

 
 
 
 
 
 

 
 
 

 

 

If  the  pump  should  lock  up  and  cease,  shut 
pump  down  (see  6.2)  and  disconnect  from 
power  supply.  Pump  must  be  uninstalled  and 
removed from the system prior to its repair. 
 

 

 

Star connection  

3 x 400 V, 50 Hz 

resp. 380-415 V, 50 Hz 

 

 

 

 

 

Delta connection  

3 x 230 V, 50 Hz 

resp. 220-240 V, 50 Hz

 

 

Screw plug 

Oil inspection window 
execution-GD only. 

Leakage G 1/8  

Summary of Contents for SBA141

Page 1: ...e 1 of 10 BRINKMANN Horizontal End Suction Pumps SBA141 143 SBF125 Brinkmann Pumpen K H Brinkmann GmbH Co KG Friedrichstraße 2 D 58791 Werdohl Tel 49 2392 5006 0 www brinkmannpumps de Fax 49 2392 5006 180 sales brinkmannpumps de Subject to change without prior notice Order No BE8140 ENGLISH ...

Page 2: ...his type are one or multi stage centrifu gal inline pumps with a compact design where the impellers are fixed on the driving shaft extension The pump shaft and motor shaft are interconnected by means of a shaft clamp These pumps are fitted out with semi open impellers and a suction screw in order to minimize the risk of cavitations SBA pumps are equipped with a single mechanical seal The SBF Pumps...

Page 3: ... removing the pump exists Proper and secured lifting tools must be used Risk of burns The pump must have cooled down sufficiently prior to commencing any repair maintenance or installa tion 3 4 Qualification and training of operating personnel The personnel responsible for operation mainte nance inspection and assembly must be adequate ly qualified Scope of responsibility and supervision of the pe...

Page 4: ...e Protect the pump against damage when transport ing The pumps may only be transported in a horizontal position and hooks or straps must be attached on the motor and pump end Do not use the pump shaft for connecting any transportation aids such as hooks or straps Pumps must be drained prior to their storage Store pump in dry and protected areas and protect it against penetration of foreign bodies ...

Page 5: ...ed wiring ports ATTENTION When Variable Frequency Drives are used interfer ing signals might occur Non sinus shaped supply voltage from a variable frequency drive might result in elevated motor temperatures 6 Start up Shut down 6 1 Start up ATTENTION Switch off at the mains After connection the electrical wires close the terminal box Briefly start the motor max 30 sec and check the rotation accord...

Page 6: ...ng faulty See above Replace impeller Replace bearing Overload trips Pump locked up mechanically High on of cycling frequency Inspect pump hydraulics Check application Power consumption is too high Wrong direction of rotation of impeller Lime or other deposits mechanical friction See above Clean pump mechanism repair pump Motor overheats High on off cycling frequency Wrong power supply voltage or c...

Page 7: ...1 7 kW DIN 912 17 Socket head cap screw DIN 912 19 Parallel pin DIN 7 22 shim ring 24 Mechanical seal 25 Circlip 26 Shaft seal 1 1 kW and over 27 Oil inspection window for GD 27 Screw plug DIN 908 28 Sealing ring DIN 7603 29 O ring Item Description 30 Shaft seal 31 Compensation disk 1 7 kW 50 Pump body 51 Motor shaft with rotor 52 Connection cover 53 Pump plate with bearing bush SBA142 143 54 Pump...

Page 8: ...te 53 and O ring 67 7 Remove the spacer sleeve 59 Use two screw drivers to push the impeller 55 from the quick shaft 91 Insert the screwdrivers between the impeller 55 and the pump plate 54 8 Remove the Woodruff key 64 from the insert shaft 91 Remove the pump plate 54 and the O ring 67 9 Remove the spacer sleeve 60 and use two screwdrivers to push the impeller 55 from the quick shaft 91 Insert the...

Page 9: ...mp 24 mm for SBA141 SBA142 and SBF125 Use a torque screwdriver to tighten each screw first with 1 3 Nm then with 2 6 Nm and finally with 4 Nm in a clockwise direction again Tighten the shaft clamp 35 mm for SBA143 Use a torque screwdriver to tighten each screw first with 2 Nm then with 3 5 Nm and finally with 5 Nm in a clockwise direction again Repeat the last turn with 5 Nm 3 times 11 Mount the p...

Page 10: ...chinenrichtlinie 2006 42 EG die Schutz ziele der Niederspannungsrichtlinie 2014 35 EU eingehalten With respect to potential electrical hazards as stated in appendix І No 1 5 1 of the machine guide lines 2006 42 EC all safety protection goals are met according to the low voltage guide lines 2014 35 EU Conformément à l annexe I N 1 5 1 de la Directive Machines 2006 42 CE les objectifs de sécurité re...

Reviews: