BRINKMANN PUMPS TAL200 Operating Instructions Manual Download Page 3

 

BE1600 

Edition

 09/2021 

Page 3 of 9 

2.3  Technical data  

 

 

 

 
 
Type 

Max. del. 
pressure bar /  
spec. weight 1 

Max. del. 
volume 
l/min 

Height

1)

  

 

mm 

Pipe 
connection

1)

 

G

 

Depth of 
immersion

1)

   

mm 

Weight  
 
kg 

Power  
50 / 60 Hz 
kW 

TAL200  /  140 

 

/  220 

 

/  290 

 

/  370 

 

/  460 

 

/  570 

0.95 

280 

223 

G 1 ¼  

  140 

 220 

  290 

  370 

  460 

  570 

  14.0 

  14.5 

  15.5 

  16.5 

  17.5 

  19.5 

0.48 / 0.55 

TAL401  /  140 
 

/  220 

 

/  290 

 

/  370 

 

/  460 

 

/  570 

0.9 

400 

264 

G 1 ½ 

  140 

 220 

  290 

  370 

  460 

  570 

15.0 

16.0 

16.5 

17.5 

19.0 

20.0 

0.85 / 0.98 

TAL601  /  150 

 

/  230 

 

/  300 

 

/  380 

 

/  470 

 

/  580 

1.3 

520 

291 

G 1 ½ 

  150 

 230 

  300 

  380 

  470 

  580 

16.0 

17.5 

18.5 

19.5 

20.5 

21.5 

1.1 / 1.27 

 

 

 

 

 

 

 

 

TGL331 /  140 

 

/  220 

 

/  290 

 

/  370 

 

/  460 

 

/  570 

0.8 

350 

264 

G 1 ½  

  140 

  220 

  290 

  370 

  460 

  570 

  16.0 

  17.0 

  17.5 

  18.5 

  20.0 

  21.0 

0.85 / 0.98 

 

 

 

 

 

 

 

 

TGL501 /  150 

 

/  230 

 

/  300 

 

/  380 

 

/  470 

 

/  580 

1.0 

430 

291 

G 1 ½  

  150 

  230 

  300 

  380 

  470 

  580 

  17.0 

  18.5 

  19.5 

  20.5 

  21.5 

  22.5 

1.1 / 1.27 

 

 

 

 

 

 

 

 

1) Dimensions in accordance with page 5 

The motor is surface-cooled and compliant with 
DIN IEC 34 and EN 60034 (protection degree IP 55).

 

 
 

Summary of Contents for TAL200

Page 1: ...ge 1 of 9 BRINKMANN Immersion Pumps TAL200 401 601 TGL331 TGL501 Brinkmann Pumpen K H Brinkmann GmbH Co KG Friedrichstra e 2 D 58791 Werdohl Tel 49 2392 5006 0 www brinkmannpumps de Fax 49 2392 5006 1...

Page 2: ...word ATTENTION is inserted 2 Description of product 2 1 General description of the pump Pumps of this type are one stage rotary pumps where the impellers are fixed on the driving shaft extension Pump...

Page 3: ...9 400 264 G 1 140 220 290 370 460 570 15 0 16 0 16 5 17 5 19 0 20 0 0 85 0 98 TAL601 150 230 300 380 470 580 1 3 520 291 G 1 150 230 300 380 470 580 16 0 17 5 18 5 19 5 20 5 21 5 1 1 1 27 TGL331 140...

Page 4: ...ards they must be guarded against acci dental contact Guards for moving parts e g coupling must not be removed from the machine while in opera tion Any leakage of hazardous e g explosive toxic hot flu...

Page 5: ...st be carried out by quali fied service personnel Pump must be discon nected from the power source and all rotating parts must stand still Reassure that pump is disconnected from power source and cann...

Page 6: ...ere is no voltage at the terminal board Open terminal box and disconnect the power leads Empty out the pump 7 Operation Liquid level According to the drawing shown below the maxi mum liquid level must...

Page 7: ...above Clean pump mechanism repair pump Motor overheats High on off cycling frequency Wrong power supply voltage or cycles Insufficient cooling See above Power supply must correspond with name plate r...

Page 8: ...m Pos 15 3 Nm Pos 18 4 5 Nm 11 Disposal When disposing of the pump or the packaging materials the local and national regulation for proper disposal must be complied with Prior to its disposal the pump...

Page 9: ...chinenrichtlinie 2006 42 EG die Schutz ziele der Niederspannungsrichtlinie 2014 35 EU eingehalten With respect to potential electrical hazards as stated in appendix No 1 5 1 of the machine guide lines...