BRINKMANN-Cutter pumps SBC152
0…1820
BE8085
Edition
11/2019
8
WARNING
Risk of fire and explosion!
The creation of an ignition spark with the pres-
ence of an ignitable Aerosol can lead to risk of
fire and explosion.
The fluid level must be above the suction
mouth of the pump during pumping of cooling-
and cutting oils in order to avoid the possibility
of the creation of an ignition spark.
– Unwanted objects, such as broken tools or
indexing plates which still lie under the
pump after stopping the working process
must be taken out in regular intervals!
– Any repair or maintenance work must be
performed after the pump has been turned
off and the shaft has come to a complete
stop. Risk of injury
!
See provided warning label!
– If the pump should lock up and cease,
shut pump down (see point 6.2) and dis-
connect from power supply. Pump must
be uninstalled and removed from the sys-
tem prior to its repair.
ATTENTION
Pulsed mode causes increased wear due to
the return flow of chips and additional load on
the bearings.
– The SBC pump should be operated in
continual operation mode,
not pulsed
mode
!
– The pump should transport medium with-
out chips for 1-2 minutes before being
switched off!
8
Servicing and Maintenance
CAUTION
Risk of burns!
– The pump must have cooled down suffi-
ciently prior to commencing any repair,
maintenance or installation.
WARNING
Risk of injury through contaminated parts!
– Pumps and pump units which convey haz-
ardous media must be decontaminated.
ATTENTION
– The surface of the motor must be kept
free of dirt.
The motor shaft is spinning in permanently
greased ball bearings and does not require any
special maintenance.
– On completion of work all safety and protec-
tive facilities must be re-installed and made
operative again.
– Prior to restarting the machine, the instruc-
tions listed under “Start up” (point 6.1) are to
be observed
8.1
Pumps with double mechanical
seal (-GD)
ATTENTION
Pumps with double mechanical seal (-GD) are
identified by the letters GLRD stamped in on the
motor side of the pump foot and must include an
oil receiver with a capacity of 1.1 litres. Check this
through the inspection window.
Oil receiver Castrol WHITEMOR WOM14 or
equivalent oil.
.