BRINKMANN PUMPS SBC1520 Operating Instructions Manual Download Page 12

BRINKMANN-Cutter pumps SBC152

0…1820 

 

 

 

BE8085 

Edition

 11/2019 

12 

11.2 

Dismantling the insert shaft  

 

 

 

 
–  Disconnect the inline pump from the mains 

both electrically and mechanically. 

 CAUTION 

Risk of burns! 

–  The pump must have cooled down suffi-

ciently prior to commencing any repair or 
maintenance. 

 WARNING 

Risk of squeezing or crushing body parts 
when installing or removing the pump ex-
ists! 

–  Secure pump with appropriate hoist. 

–  Remove pump from system. Secure pump 

against tipping over, i.e. use ropes to secure 
pump. 

–  Empty out the Pump and dismantle the pump 

unit.  

 WARNING 

Risk of injury due to sharp edges on pump 
components, i.e. impeller blades! 

–  Wear safety gloves! 

–  Dismantle the pump body and the pump 

foot. 

 WARNING 

Risk of injury by discharging parts! 

–  Do not, under any circumstances, re-

move the screws on the shaft clamp (1) 
completely. 

–  Loosen the screws on the shaft clamp (1). 
–  Remove the insert shaft (2) and shaft clamp 

(1) off the motor shaft (3). 

11.3 

Assembling the insert shaft and 
motor shaft   

 WARNING 

Risk of jamming or crushing during pump 
installation or removal! 

–  Secure pump with appropriate hoist. 

 ATTENTION  

–  Clean the contact surfaces of the insert 

shaft (2) (inside) and the motor shaft (3). 
They must not be lubricated or oiled. 

–  Disassemble the fan cover and the fan from 

the motor. Set the pump down on the end of 
the shaft (a fixture must be used). 

–  Position the shaft clamp (1) (use a new shaft 

clamp) in the centre of the cranked clamping 
diameter (2) of the insert shaft. 

–  Insert the motor shaft (3) into the insert shaft 

(2). 

–  Tighten:  

Mark the first screw and tighten all the screws 
evenly by hand, one after the other in a clock-
wise direction (not cross-ways). 

–  Use a torque screwdriver to tighten each 

screw first with 2 Nm then with 3.5 Nm and fi-
nally with 5 Nm (in a clockwise direction 
again). 

–  Repeat the last turn (with 5 Nm) 3 times. 

 

 WARNING 

Risk of injury due to sharp edges on pump 
components, i.e. impeller blades! 

–  Wear safety gloves! 

–  Mount the pump foot and the pump body. 

–  The remainder of the reassembly process is 

to be completed in the opposite order of the 
prior described dismantling process. 

  

 

 1 

  

 1 = Shaft clamp 
 2 = Insert shaft 
 3 = Motor shaft  

Drawing 6

 

Summary of Contents for SBC1520

Page 1: ...019 1 BRINKMANN Horizontal End Suction Pumps SBC1520 1820 Brinkmann Pumpen K H Brinkmann GmbH Co KG Friedrichstra e 2 D 58791 Werdohl Tel 49 2392 5006 0 www brinkmannpumps de Fax 49 2392 5006 180 sale...

Page 2: ...AUTION indicates a hazardous situation which if not avoided could result in mi nor or moderate personal injury The signal word ATTENTION indicates a hazard ous situation which if not avoided may cause...

Page 3: ...1 5 Chip geometry Chip bundles to max 100 mm Kinetic viscosity of the medium 45 mm2 s Temperature of me dium 0 80 C Dry running Dry running causes in creased wear and should be avoided During the test...

Page 4: ...of the op erating manual are fully understood by the personnel 3 5 Safety instructions relevant for operation If hot or cold machine components involve hazards they must be guarded against acci denta...

Page 5: ...iate hoist During any assembly or disassembly pro cess the pumps must be secured against tipping trough ropes for example at all times The pumps must be securely mounted to the tank CAUTION Risk of cu...

Page 6: ...ectric shock All service work must be carried out by quali fied service personnel Pump must be discon nected from the power source and all rotating parts must stand still Reassure that pump is disconn...

Page 7: ...e discon nected from the power source and all rotating parts must stand still Reassure that pump is disconnected from power source and cannot be switched on Verify that there is no voltage at the term...

Page 8: ...ional load on the bearings The SBC pump should be operated in continual operation mode not pulsed mode The pump should transport medium with out chips for 1 2 minutes before being switched off 8 Servi...

Page 9: ...m repair pump Motor overheats High on off cycling frequency Wrong power supply voltage or cycles Insufficient cooling See above Power supply must correspond with name plate rating Check air flow at mo...

Page 10: ...20 27 Oil inspection window 27 Screw plug DIN 908 28 Sealing ring DIN 7603 29 O ring 30 Shaft seal 31 Socket head cap screw with lock DIN 912 32 Nut SBC1820 DIN 934 Item Description 50 Pump body 51 In...

Page 11: ...e the key 79 from the insert shaft 91 and remove the spacer sleeve 57 Use two screwdrivers to push the impeller 75 from the insert shaft 91 Insert the screwdrivers between the impeller 75 and the pump...

Page 12: ...d motor shaft WARNING Risk of jamming or crushing during pump installation or removal Secure pump with appropriate hoist ATTENTION Clean the contact surfaces of the insert shaft 2 inside and the motor...

Page 13: ...g 27 Pump Installation Secure pump against fall ing over i e with use of safety straps Reconnect immersion pump as described in point 5 ATTENTION When putting the pump back into use make sure the dire...

Page 14: ...2006 42 EG die Schutz ziele der Niederspannungsrichtlinie 2014 35 EU eingehalten With respect to potential electrical hazards as stated in appendix No 1 5 1 of the machine guide lines 2006 42 EC all...