BRINKMANN PUMPS SBC1520 Operating Instructions Manual Download Page 1

BE8085 

Operating Instructions 

(Translation of original)

 

 

©

 Brinkmann Pumpen 

Edition

 11/2019 

1

 

 

BRINKMANN-Horizontal End Suction Pumps 

SBC1520...1820 

Brinkmann Pumpen 
K. H. Brinkmann GmbH & Co. KG 

Friedrichstraße 2    D-58791 Werdohl 

Tel.:  +49-2392 / 5006-0  

www.brinkmannpumps.de 

Fax.: +49-2392 / 5006-180  

[email protected] 

 
Subject to change without prior notice.

  

Order - No.: BE8085 ENGLISH 

 

Summary of Contents for SBC1520

Page 1: ...019 1 BRINKMANN Horizontal End Suction Pumps SBC1520 1820 Brinkmann Pumpen K H Brinkmann GmbH Co KG Friedrichstra e 2 D 58791 Werdohl Tel 49 2392 5006 0 www brinkmannpumps de Fax 49 2392 5006 180 sale...

Page 2: ...AUTION indicates a hazardous situation which if not avoided could result in mi nor or moderate personal injury The signal word ATTENTION indicates a hazard ous situation which if not avoided may cause...

Page 3: ...1 5 Chip geometry Chip bundles to max 100 mm Kinetic viscosity of the medium 45 mm2 s Temperature of me dium 0 80 C Dry running Dry running causes in creased wear and should be avoided During the test...

Page 4: ...of the op erating manual are fully understood by the personnel 3 5 Safety instructions relevant for operation If hot or cold machine components involve hazards they must be guarded against acci denta...

Page 5: ...iate hoist During any assembly or disassembly pro cess the pumps must be secured against tipping trough ropes for example at all times The pumps must be securely mounted to the tank CAUTION Risk of cu...

Page 6: ...ectric shock All service work must be carried out by quali fied service personnel Pump must be discon nected from the power source and all rotating parts must stand still Reassure that pump is disconn...

Page 7: ...e discon nected from the power source and all rotating parts must stand still Reassure that pump is disconnected from power source and cannot be switched on Verify that there is no voltage at the term...

Page 8: ...ional load on the bearings The SBC pump should be operated in continual operation mode not pulsed mode The pump should transport medium with out chips for 1 2 minutes before being switched off 8 Servi...

Page 9: ...m repair pump Motor overheats High on off cycling frequency Wrong power supply voltage or cycles Insufficient cooling See above Power supply must correspond with name plate rating Check air flow at mo...

Page 10: ...20 27 Oil inspection window 27 Screw plug DIN 908 28 Sealing ring DIN 7603 29 O ring 30 Shaft seal 31 Socket head cap screw with lock DIN 912 32 Nut SBC1820 DIN 934 Item Description 50 Pump body 51 In...

Page 11: ...e the key 79 from the insert shaft 91 and remove the spacer sleeve 57 Use two screwdrivers to push the impeller 75 from the insert shaft 91 Insert the screwdrivers between the impeller 75 and the pump...

Page 12: ...d motor shaft WARNING Risk of jamming or crushing during pump installation or removal Secure pump with appropriate hoist ATTENTION Clean the contact surfaces of the insert shaft 2 inside and the motor...

Page 13: ...g 27 Pump Installation Secure pump against fall ing over i e with use of safety straps Reconnect immersion pump as described in point 5 ATTENTION When putting the pump back into use make sure the dire...

Page 14: ...2006 42 EG die Schutz ziele der Niederspannungsrichtlinie 2014 35 EU eingehalten With respect to potential electrical hazards as stated in appendix No 1 5 1 of the machine guide lines 2006 42 EC all...

Reviews: