20
5HQRYHQW([FHOOHQW)
6HWWLQJWKHDLUÀRZUDWH
Proper ventilation contributes to healthy air in the home, opti-
PXPFRPIRUWDQGÀDZOHVVSHUIRUPDQFHRIWKHLQVWDOODWLRQ
7KHIDFWRU\VXSSOLHVWKH5HQRYHQW([FHOOHQWÀRZUDWHVVHW
to 50, 100, 200 and 300 m
3
/h.
The performance and the energy consumption of the Renovent
Excellent depend on the pressure drop in the duct system as
ZHOODVRQWKH¿OWHUUHVLVWDQFH
Important:
Mode
:
Holiday mode
50 m
3
/h (not in combination with a 3-way switch).
Mode 1
:
Absence mode
$ERXWRIWKHGHVLJQÀRZUDWH
Must always be lower than mode 2.
Mode 2
:
Presence mode
RIWKHGHVLJQÀRZUDWH
Must always be lower than mode 3;
Mode 3
:
Cooking/showering mode
RIWKHGHVLJQÀRZUDWHRUWKHPD[LPXPXQLW
capacity
$GMXVWDEOHEHWZHHQDQGP
3
/h;
,IWKHVHFRQGLWLRQVDUHQRWFRPSOLHGZLWKWKHDLUÀRZUDWHRIWKH
KLJKHUPRGHZLOODXWRPDWLFDOO\EHDGMXVWHG
6HHWKHVHWWLQJVPHQXIRUFKDQJLQJWKHÀRZUDWHV
Chapter 7 Putting into operation
7.4 Factory setting
,WLVSRVVLEOHWRUHVHWDOOPRGL¿HGVHWWLQJVEDFNWRIDFWRU\VHW
-
ting in one go.
$OOPRGL¿HGVHWWLQJVZLOOEHDWWKHYDOXHVWKH\KDGZKHQWKH
Renovent Excellent was supplied from the factory; all message
codes / fault codes will be erased from the service menu as
well.
7KH¿OWHUQRWL¿FDWLRQSURFHVVZLOOQRWUHVHW
7.3 Other settings installer
Various other settings of the Renovent Excellent can also be
PRGL¿HG+RZWRPRGLI\WKHVHLVH[SODLQHGLQ
operating mode
3 sec. visible
press > 10 sec.
simultaneously