SITING THE APPLIANCE
This appliance may be fixed to any suitable flat
vertical non-conductive surface and does not
require a cut out in the wall. The appliance must
be positioned at least 100mm above any skirting
board and 300mm above any surface beneath the
fire. There must be at least 25mm clearance
between the top of the surround and any object
such as a shelf or wall mounted TV. This is to
allow easy removal of the fireplace surround
during maintenance. The electric supply may be
concealed or surface mounted.
INSTALLATION
Newdawn Electric is supplied fully assembled.
DO NOT REMOVE THE GLASS PANEL.
Remove the two screws from the bottom of the
fire surround. Remove the fire surround by pulling
out at the bottom and lifting upwards.
The fixing kit and the power supply lead are tied in
place at the bottom right of the wall plate. Remove
these before commencing fitting.
When drilling holes for the wall plugs use a 7mm
drill for hollow substrates and use a 8mm drill for
solid or combination substrates.
Using the diagram above mark the positions of the
top keyhole fixings on the wall, drill two holes,
insert wall plugs (supplied) and fix two screws
(supplied). Tighten the screws to within 3mm from
the wall surface. Carefully hang the appliance on
the two screws.
The electrical supply is a concealed entry, mark
the cable entry point on the wall, remove the
appliance and carry out the necessary work to
create the concealed electrical supply. Carefully
re-hang the appliance on the two screws.
750
51
155
CABLE
ENTRY