8
z
Press “CHANNEL” button (B6) to view the 3 Channels’ temperature. The sequence is shown
as follow:
Press
Press
Press
“CHANNEL” button
“CHANNEL” button “CHANNEL” button
Display the three
channels alternatively
z
Hold “ CHANNEL” (B6) button for 3 seconds to cancel unused channel. It will automatically
register a new channel again if a new channel is received.
If there is no temperature displayed in existing channel (“
- - . –“
is displayed on the LCD ),
hold “CHANNEL” button (B6) for 3 seconds to cancel that channel and receive the channel
again (“Beep” sound can be heard.) Then, press “ TX “ button (D7) on the thermo sensor unit
to transmit signal to the main unit manually
z
The trend pointer displayed (A2) indicates the trend of the outdoor temperature.
“
” indicates the outdoor temperature is increasing.
“
” indicates the outdoor temperature is steady.
“
” indicates the outdoor temperature is decreasing.
z
Press “ °C /°F” button (D6), on the Thermo Sensor unit, to select Temperature to be displayed
in Celsius mode or Fahrenheit mode.
The use of 1.5m cord Temperature Probe:
z
Insert the Sensor probe (D9) to the right hand side of the Thermo Sensor Unit.
z
Put the metal casing outside and leave the Thermo Sensor Unit in an indoor area to avoid
freezing up the battery when the outdoor temperature is below -20 °C.
z
Always use the temperature probe to sense the temperature when the temperature is between
the following range:
-50 °C ~ 0°C and +50°C ~ + 70°C
Manual Time Setting:
z
Hold “ MODE” button (B3) for 3 seconds to enter Clock/Calendar setting Mode .
z
Press “+” (B2) or “-” (B4) buttons to adjust the setting and press “MODE” button (B3) to
confirm each setting.