PROGRAMMING THE UNIT
PUMP SPEED/FLOW RATE AND CALIBRATION
STEP 5
From here, you can change the Pump Speed using the
UP
or
DOWN
arrow.
STEP 6
To calibrate the pump press the
PRIME
button once to
display the calibration menu.
(
This is only if the unit is set to Fl. oz or ML
)
STEP 7
Once in the calibration menu, you can adjust the time
you wish to calibrate the pump for, using the
PRIME
but-
ton. To begin the calibration press the
TEST
button.
Adjust Speed
Confirm &
Advance
PUMP SPEED
100%
Enter
Calibration
Menu
PUMP SPEED
100%
Adjust Calibration Time
Start
Calibration
PUMP ONE
CALIBRATE FOR
60 SECONDS
STEP 8
Once completed press the
TEST
button again to re-
turn to the main screen. Then press the
PUMP STOP/
STANDBY
button to enter
FLOWRATE MENU
. Use the
UP
and
DOWN
arrows to adjust.
RIGHT
to save.
Start
Calibration
PUMP ONE
CALIBRATE FOR
60 SECONDS
ENTER PUMP 1
FLOWRATE
0000 ML
Adjust Flowrate
Enter
Flowrate
Menu