PROGRAMMING - CONTROLS

Throughout the instructions: 
If a button or buttons are 

shown in 

BLUE

 then 

they must be pressed to 

progress to the next stage. 

(If two buttons are shown, 

they must be pressed 

together)

PROGRAMMING - KEY TO INSTRUCTIONS

If buttons are shown in 

GREY

, they are used 

individually to achieve the 

desired result. (ie. Either/or)

SIGNAL

ACCEPTANCE TIME

00 SECONDS

MAN 1: ------------------

MAN 2: ------------------

MAN 3: ------------------

OFF P: -------------------

FLUSH VALVE

TIME

00 MINS 00 SECS

Throughout the instructions, 

there are several screens 

which are highlighted 

BOLD.

From any point within the 

program, the user can 

transition to the next 

BOLD

 

screen via the 

SEE/JUMP

 

button.

Summary of Contents for Brightlogic 2

Page 1: ...Brightlogic 2 Quickstart Guide Installation and Setup Brightwell co uk Revision 1 0 05 2022 B1051EN...

Page 2: ...TALLATION MOUNTING 4 INSTALLATION WIRING 1 5 INSTALLATION WIRING 2 6 PROGRAMMING CONTROLS 7 PROGRAMMING KEY TO INSTRUCTIONS 7 PROGRAMMING LANGUAGE SELECTION 8 FLOW DIAGRAM INSTRUCTIONS 9 FLOW DIAGRAM...

Page 3: ...lace heavy objects on top of the unit Do not attempt to place items such as screwdrivers into the moving parts of the pumphead Do not power the unit outside of the values stated on the rating label Do...

Page 4: ...ws provided Ensure that the unit is level and positioned no more than 2 metres above the base of the product which is to be dispensed Important notes Maximum recommended suction and delivery tubes 2 m...

Page 5: ...90 volts AC or DC min 12V Lorem ipsum B Rail Negative With the switches in an upright position a common neutral nega tive input signal can be taken to the B Rail A Rail Positive The positive live sig...

Page 6: ...RAIL B Rail Negative With the switches in an upright position a common neutral nega tive input signal can be taken to the B Rail Separate connections are provided on input 2 for Hot Cold wash signals...

Page 7: ...ed together PROGRAMMING KEY TO INSTRUCTIONS If buttons are shown in GREY they are used individually to achieve the desired result ie Either or SIGNAL ACCEPTANCE TIME 00 SECONDS MAN 1 MAN 2 MAN 3 OFF P...

Page 8: ...nter the correct four digit access code using the UP and DOWN keys to select a number and the FWD ACCEPT key to move see page 15 Use the UP and DOWN keys to scroll through the language options Press t...

Page 9: ...PUMP 1 SPEED 100 SET PUMP 1 FLOWRATE 00000ML 01 01 2015 SET PUMP 1 SPEED 60S 100 SAVE SETTINGS NEXT PAGE NEXT PAGE MAN1 1 MAN 2 MAN 3 OFF 1 2 3 4 5 6 7 8 9 0 01 STANDARD MODE 00 10 01 01 2015 DATE TIM...

Page 10: ...UT 01 PUMP 01 SET DELAY TIME 00 MIN 00 SECS PROGRAM 01 LOAD COUNT PUMP 03 PROGRAM 01 PUMP 1 LEVEL 2 DISABLE PROGRAM 01 PUMP 2 LEVEL 1 SET RUN TIME 00 MIN 00 SEC MASTER LOAD COUNT PUMP 04 PROGRAM 02 ST...

Page 11: ...a to Previous program resets to the previous program The unit can be manually reset by pressing the up and down keys together for 1 second Without a Formula Select module If there is no formula select...

Reviews: