background image

Clearing Timing Entries 

(access code protected)

 

Using the + and - keys, select the Channel that you wish 
to clear. 

Press ACCEPT to clear ALL the timing entries of the 
chosen channel. 

PROGRAM MODE

Clear timing entries
Channel 1

PROGRAM MODE

Clear timing entries
Channel 1
Please wait

Enabling and Disabling Channels 

Using the + and - keys, select the Channel that you wish 
to ENABLE/DISABLE. 

PROGRAM MODE

Enable channel  
Channel 1

Using the + and - keys, select the Channel to be 
ENABLED or DISABLED. 

Currently ENABLED

CHANNEL 1

The DISABLE function will stop a channel from operating without the need to 
clear the programmed timing entries.  Note that a DISABLED channel cannot be 
OVER-RIDDEN. 

Summary of Contents for Bright-time

Page 1: ...BRIGHTFLOW CHEMICAL DISPENSING SYSTEMS B926 v1 0 4 CHANNEL REAL TIME CLOCK...

Page 2: ...in a continuous TIMED mode or a pulsed CYCLIC mode The 4 outputs can be individually selected to be used as volt free Max 6A contacts or to give a 24V DC output Max 0 7A 16W The volt free contact opti...

Page 3: ...3 NO C GND CH1 CH2 CH3 CH4 NO C GND NO C GND NO C GND 230V Installation Diagram 1 2 24V 0V NO C GND CH1 CH2 CH3 CH4 NO C GND NO C GND NO C GND...

Page 4: ...C GND NO C GND BRIGHTWELL DISPENSERS 230V L N E 24VDC 0V 24VDC 0V 24VDC 0V 24VDC 0V NO 24VDC when ON C N A GND Ground With the links in place the relevant outputs will supply 24V DC Channel 1 LK1 LK2...

Page 5: ...ND NO C GND BRIGHTWELL DISPENSERS 230V L N E NO C NO C NO C NO C NO Normally open C Common GND N A With the links removed the relevant outputs will be set to operate as zero volt contacts Channel 1 LK...

Page 6: ...s the Accept key to enter the program mode menu Scroll through the menu using the and keys Select the required option by pressing the Enter key PROGRAM MODE Program channel View channel PROGRAM MODE P...

Page 7: ...er PIN number 0 When selecting one of these options the following screen will be displayed Use the and key to enter your 4 digit access code and press the ACCEPT key to move on During programming the...

Page 8: ...ayed briefly whilst the information is stored WARNING For safety saving will turn off Channel 1 1 If the programmed entry is currently active then it will revert to an off state once edited This warni...

Page 9: ...ear timing entries Channel 1 Please wait Enabling and Disabling Channels Using the and keys select the Channel that you wish to ENABLE DISABLE PROGRAM MODE Enable channel Channel 1 Using the and keys...

Page 10: ...urrent time and date pressing ACCEPT to move on PROGRAM MODE Set up system Edit date and time 00 00 dd mm yy Setting the day date and time access code protected Press ACCEPT to edit the date and time...

Page 11: ...cannot be OVER RIDDEN The OVER RIDE facility allows any one or all of the channels to be reversed in state If the channel is ON then it will be switched OFF and if the channels is OFF then it will be...

Page 12: ...closure IP66M ABS Supply 230V 50 60Hz Fusing T400mA Maximum Outputs Volt free 250V 6A DC 24V DC 0 7A Clock Accuracy 4 Min Yr Approvals EMC 89 336 EEC EN50081 1 EN50082 1 LVD 72 23 EEC EN60335 1 OVER R...