Technical Specification: 

Construction  

Housing  

Black Die-cast Aluminum Body, Iron Yoke 

Cooling System  

Passive fanless, Temperature protection 

Power Input/Output 

Neutrik Powercon  

DMX Input/Output 

5-pin XLR  

Display 

Blue/white Backlit LCD, auto-dimmed when idle. 

Dimension (LxWxH) 

102 x 263 x 287 mm 

Weight  

3.4kg (clamp included)  

Electric  

Power supply  

100-240V AC, 50/60 Hz  

Power consumption 

98W,  0.9A@120V   0.5A@230V 

LED Driver  

Constant Current Driver, 2940Hz (Flicker Free) 

Fuse  

T2A , 250V 

Optics 

 

Light Source  

12 pcs of 4in1 RGBW 8W LED 

Luminous Flux (1m)  

R3957

G3900

B4690, W6000, RGBW15740 

Beam/Field Angle  

22°/35° 

Functions 

 

Control Modes  

DMX512, Static Color, Auto, Sound, Master/Slave 

DMX Channels  

3/4/6/9CH 

Operation

 

Temperature 

Max ambient temperature Ta: 40°C 
Max housing temperature Tc (steady state): 80°C 

Distance 

Min. distance from flammable surfaces: 0.5 m 
Min. distance to lighted object: 0.1 m 

Compliance 

 

LVD 

EN60598-2-17:1989+A2:1991 
EN60598-1:2008+A11:2009 

EMC 

EN55015:2006+A1:2007+A2:2009 
EN61547:2009 
EN61000-3-2:2006+A2:2009 
EN61000-3-3:2008 

Summary of Contents for 437613

Page 1: ...1 by Software version 1 4 ...

Page 2: ...02 287 Ø200 219 263 Width 590 XLED Tourpack 1 x Flightcase 10 x Bright XLED 10 x Hook clamp 10 x Schuko PowerCon 10 x Safety wire Art no XLED basic 1 x Bright XLED 1 x Hook clamp 1 x Schuko PowerCon Art no 437613 ...

Page 3: ...idity may affect it O Do not connect this device to a dimmer or other regulated power O Only connect this device to a grounded and protected circuit O Switchmode powers has high inrush currents do not exceed 8A on the output Powercon when daisy chaining fixtures 16 units 230V Main Features O High Output 12x8w 4in1 RGBW led engine O Flicker free high speed PWM dimming O Industry standard 5pin XLR a...

Page 4: ...he main menu with the Up Down buttons and use the Enter Confirm button to select a menu item The XLED will return to its previous state if no new setting or mode has been confirmed within 10 seconds DMX start Address Use Up Down to alter the DMX start Address 001 512 then press Enter Confirm to set the chosen start address permanently O Setting the DMX start Address will activate DMX Mode DMX Chan...

Page 5: ... Enter to adjust the color temperature W1 W11 then set intensity value D100 000 then press Enter confirm to set Manual White permanently O Setting a manual white will activate Color Set Mode Automatic Programs Use Up Down to select the built in program Pr01 Pr06 press Enter Confirm then use Up Down to select the operating speed of the program Sp000 Sp100 and press Enter Confirm to start Auto Progr...

Page 6: ...und static or manual color with Master enabled the Master fixture will transmit and remote control any fixtures set to Slave Mode O Setting Master Slave to Slave will activate Slave MODE Factory Reset Use Up Down to select Y for yes then press Enter confirm to reset the fixture to factory default settings O Resetting the fixture will activate DMX Mode ...

Page 7: ...lorfades Pr06 Special chaser mode Special Chaser Mode program Pr06 This mode enables cascading delay being applied to connected slave units to create running lights chaser effects without a Lighting console up to 255 groups Settings for the master XLED 1 Set the DMX address to total number of groups e g 003 2 Set Auto Program to Pr06 master is always part of group 1 Settings for the slave XLED s 1...

Page 8: ...8 Photometrics R G B W RGBW 1m 3957 3900 4690 6000 15740 2m 977 1092 1200 1700 4310 3m 430 485 558 747 1911 4m 245 280 308 428 1056 5m 160 185 205 282 693 Beam Angle 22º Field Angle 35º Center Lux ...

Page 9: ...9 ...

Page 10: ...9 Red 0 Green 100 0 Blue 100 100 119 Red 0 100 Green 0 Blue 100 120 139 Red 100 Green 0 Blue 100 0 140 159 Red 100 Green 0 100 Blue 0 100 160 179 Red 100 0 Green 100 0 Blue 100 180 200 Red 100 Green 100 Blue 100 White 100 201 255 Color Temperature Warm Cool 8 000 009 No Function 010 049 Auto Program 1 R G B W hard chase 050 090 Auto Program 2 15 colors hard chase 091 131 Auto Program 3 R G B W sof...

Page 11: ...Constant Current Driver 2940Hz Flicker Free Fuse T2A 250V Optics Light Source 12 pcs of 4in1 RGBW 8W LED Luminous Flux 1m R3957 G3900 B4690 W6000 RGBW15740 Beam Field Angle 22 35 Functions Control Modes DMX512 Static Color Auto Sound Master Slave DMX Channels 3 4 6 9CH Operation Temperature Max ambient temperature Ta 40 C Max housing temperature Tc steady state 80 C Distance Min distance from flam...

Page 12: ...iliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual Bright Norway AS Brenneriveien 11 N 0182 Oslo Norway brightgroup no ...

Reviews: