Engine Maintenance

Oil

Oil Recommendations

We recommend the use of Briggs & Stratton Warranty
Certified oils for best performance. Other high-quality
detergent oils are acceptable if classified for service SF, SG,
SH, SJ or higher. DO NOT use special additives.

Outdoor temperatures determine the proper oil viscosity for
the engine. Use the chart to select the best viscosity for the
outdoor temperature range expected.

* Below 40°F (4°C) the use of SAE 30 will result in hard starting.

** Above 80°F (27°C) the use of 10W30 may cause increased oil

consumption. Check oil level more frequently.

NOTICE  

Synthetic oil meeting ILSAC GF-2, API

certification mark and API service symbol with
“SJ / CF ENERGY CONSERVING” or higher, is an
acceptable oil at all temperatures. Use of synthetic
oil does not alter required oil change intervals.

Checking Oil Level

Oil level should be checked prior to each use or at least
every 8 hours of operation. Keep oil level maintained.

1. Make sure generator is on a level surface.

2. Clean area around oil fill and remove oil fill cap.

3. Verify oil is at the point of overflowing at oil fill

opening.

4. Replace and tighten oil fill cap.

Adding Engine Oil

1. Make sure generator is on a level surface.

2. Check oil level as described in 

Checking Oil Level

.

3. If needed, slowly pour oil into oil fill opening to the

point of overflowing at oil fill.

4. Replace and tighten oil fill cap.

Changing Engine Oil

If you are using your generator under extremely dirty or
dusty conditions, or in extremely hot weather, change the oil
more often.

KEEP OUT OF REACH OF CHILDREN. DON’T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.

Change the oil while the engine is still warm from
running, as follows:

1. Make sure unit is on a level surface.

2. Disconnect the spark plug wire from the spark plug and

place the wire where it cannot contact spark plug.

3. Clean area around oil drain plug (

A

). The oil drain plug

is located at base of engine, opposite carburetor.

4. Remove oil drain plug and drain oil completely into a

suitable container.

5. Reinstall oil drain plug and tighten securely. Remove oil

fill cap.

6. Slowly pour oil (about 28 oz.) into oil fill opening (

B

) to

the point of overflowing (

C

) at oil fill cap. DO NOT

overfill.

7. Reinstall oil fill cap. Finger tighten cap securely.

8. Wipe up any spilled oil.

9. Reconnect spark plug wire to spark plug.

16

BRIGGSandSTRATTON.COM

A

B

C

CAUTION   

Avoid prolonged or repeated skin contact

with used motor oil.

• Used motor oil has been shown to cause skin cancer in certain

laboratory animals.

• Thoroughly wash exposed areas with soap and water.

WARNING   

Unintentional sparking could cause fire or

electric shock resulting in death or
serious injury.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

• Disconnect the spark plug wire from the spark plug and place

the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

• Use approved spark plug tester.

• DO NOT check for spark with spark plug removed.

Not 

for  

Reproduction

Summary of Contents for Storm Responder 5500

Page 1: ...KEE WISCONSIN U S A Manual No 206883GS Revision E Portable Generator Operator s Manual This generator is rated in accordance with CSA Canadian Standards Association standard C22 2 No 100 04 motors and...

Page 2: ...electrical lighting appliances tools and motor loads and is not intended for any other purpose It is important that you read and understand these instructions thoroughly before attempting to start or...

Page 3: ...ols 10 Cord Sets and Receptacles 11 Generator Adapter Cord Set 11 Operation 12 Starting the Engine 12 Connecting Electrical Loads 13 Stopping the Engine 13 Don t Overload Generator 14 Maintenance 15 M...

Page 4: ...cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all inclusive If you use a...

Page 5: ...uel cap Loosen cap slowly to relieve pressure in tank Fill or drain fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion If fuel spills wait until it evaporates before starting engin...

Page 6: ...ould ignite combustibles structures or damage fuel tank causing a fire resulting in death serious injury and or property damage Contact with muffler area could cause burns resulting in serious injury...

Page 7: ...follows 1 Tip generator so that engine end is up 2 Slide axle A through both mounting brackets 3 Slide a wheel B over axle NOTICE Be sure to install wheel with raised hub inboard 4 Place a washer C o...

Page 8: ...to a different fuel provider or change brands This engine is certified to operate on gasoline The emission control system for this engine is EM Engine Modifications 1 Clean area around fuel fill cap r...

Page 9: ...as A could accumulate and enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes or other openings that can allow exha...

Page 10: ...J Grounding Fastener Consult your local agency having jurisdiction for grounding requirements in your area K Identification Label Provides model revision and serial number of generator Please have the...

Page 11: ...erator output capacity NEVER attempt to power a device requiring more amperage than generator or receptacle can supply DO NOT overload the generator See Don t Overload Generator 120 Volt AC 20 Amp Dup...

Page 12: ...pped with a low oil protection device If so oil must be at proper level for engine to start 12 BRIGGSandSTRATTON COM WARNING Starter cord kickback rapid retraction will pull hand and arm toward engine...

Page 13: ...mperage capacity See Don t Overload Generator in the Operation section Start generator and let engine stabilize before connecting electrical loads Connect electrical loads in OFF position then turn ON...

Page 14: ...ut to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load...

Page 15: ...lots in the generator must not become clogged with snow leaves or any other foreign material NOTICE DO NOT use water or other liquids to clean generator Liquids can enter engine fuel system causing po...

Page 16: ...ng Engine Oil If you are using your generator under extremely dirty or dusty conditions or in extremely hot weather change the oil more often KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOU...

Page 17: ...er as follows 1 To remove muffler heat shield A from muffler B remove four screws that connect guard to muffler bracket 2 Remove four screws that attach spark arrester screen C 3 Inspect screen and ob...

Page 18: ...his reason we recommend that you have an authorized Service Dealer check and adjust valve clearance at recommended intervals see Maintenance Schedule in the Maintenance section Carburetor Adjustment T...

Page 19: ...Oil While engine is still warm drain oil from crankcase Refill with recommended grade See Changing Engine Oil Other Storage Tips 1 DO NOT store fuel from one season to another unless it has been treat...

Page 20: ...lve is in Off position 3 Low oil level 4 Dirty air cleaner 5 Out of fuel 6 Stale fuel 7 Spark plug wire not connected to spark plug 8 Bad spark plug 9 Water in fuel 10 Flooded 11 Excessively rich fuel...

Page 21: ...failed due to abuse neglect improper maintenance or unapproved modifications You are responsible for presenting your engine equipment to a B S distribution center servicing dealer or other equivalent...

Page 22: ...at are not original equipment B S parts or to parts that fail due to abuse neglect or improper maintenance as set forth in the B S engine warranty policy B S is not liable for warranty coverage of fai...

Page 23: ...ou for being inconvenienced Any Authorized Service Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may not be appropriate Fo...

Page 24: ...not limited to the variety of engine components air cleaner exhaust charging cooling carburetor fuel pump etc application limitations ambient operating conditions temperature humidity altitude and eng...

Page 25: ...st clasificado conforme a la norma C22 2 No 100 04 motores y generadores de la CSA Canadian Standards Association Asociaci n canadiense de normalizaci n BRIGGS STRATTON POWER PRODUCTS GROUP LLC MILWAU...

Page 26: ...originales para futuras consultas Este generador requiere montaje final antes de ser usado Consulte la secci n Montaje de este manual donde encontrar instrucciones para el montaje final Siga las instr...

Page 27: ...de cordones y enchufes conectores 11 Juego de cables del adaptador del generador 11 Operando 12 Encienda el motor 12 Conexi n de cargas el ctricas 13 Parada del motor 13 No sobrecargar el generador 14...

Page 28: ...fabricante debe asegurarse de que no entra a peligro para usted ni para otras personas Tambi n debe asegurarse de que el procedimiento m todo de trabajo o t cnica operativa elegida no hace que el gene...

Page 29: ...emasiado el tanque Permita al menos espacio para la expansi n del combustible Si se ha derramado combustible espere a que se evapore antes de arrancar el motor Mantenga la combustible alejada de chisp...

Page 30: ...s manos y los pies est n mojados NO permita que personas descalificadas o ni os operen o sirvan al generador ADVERTENCIA Las chispas involuntarias podr an provocar incendios o electrocuci n que pueden...

Page 31: ...de ruedas 1 Voltee el generador de forma que el motor quede arriba 2 Introduzca el eje A a trav s de los dos soportes de montaje 3 Monte una rueda B en el eje AVISO Compruebe que instala la rueda con...

Page 32: ...a cambiar de proveedor o de marca Este motor est certificado para funcionar con gasolina Su sistema de control de emisiones es EM Modificaciones del motor 1 Limpie el rea alrededor de la tapa de llena...

Page 33: ...o Aseg rese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaci n u otras aberturas en un espacio cerrado en el que puedan acumularse Tenga en cuenta los viento...

Page 34: ...iado de Aceite Permite vaciar el aceite del motor J Conector de Tierra Consulte con el organismo responsable de la normativa vigente de conexi n a tierra K Etiqueta de Identificaci n Proporciona el mo...

Page 35: ...as el ctricas pueden marcar un valor nominal mayor que la capacidad de salida del generador NUNCA intente conectar un dispositivo que requiera m s amperaje del que el generador o la toma el ctrica pue...

Page 36: ...con un dispositivo de protecci n de bajo nivel de aceite En caso afirmativo el nivel del aceite debe ser adecuado para que el motor arranque 12 BRIGGSandSTRATTON COM ADVERTENCIA El retroceso repliegue...

Page 37: ...el motor se estabilice antes de conectar las cargas el ctricas Conecte las cargas el ctricas en la posici n de apagado OFF luego encienda ON para su operaci n Apague OFF las cargas el ctricas y desco...

Page 38: ...or es a adir las cargas secuencialmente como se indica a continuaci n 1 Sin tener nada conectado al generador encienda el motor tal como se describe en este manual 2 Conecte y encienda la primera carg...

Page 39: ...ro material extra os Revise frecuentemente la limpieza del generador y l mpielo cuando est con polvo sucio con aceite humedad o cuando otras substancias extra as sean visibles en su superficie exterio...

Page 40: ...firmemente Adici n de aceite del motor 1 Aseg rese de que la generador est en una superficie plana 2 Compruebe el nivel de aceite tal como se indica en la secci n Comprobaci n del nivel de aceite 3 Si...

Page 41: ...ajuste el espacio de la buj a a la medida recomendada si fuera necesario v ase Especificaciones 5 Instale la buj a y apriete firmemente Inspeccione el silenciador y la pantalla apagachispas Inspeccion...

Page 42: ...vula Si comprueba y ajusta la holgura de la v lvula regularmente el funcionamiento del motor mejorar y tendr una mayor vida til Este procedimiento no puede llevarse a cabo sin desmontar parcialmente e...

Page 43: ...ado Cambio de aceite Con el motor todav a caliente drene el aceite de la caja del cig e al Vuelva a llenarlo con el grado de aceite recomendado Otras sugerencias para el almacenamiento 1 NO guarde com...

Page 44: ...sa 9 Agua en la combustible 10 Sobrecebado 11 Mezcla de combustible excesivamente rica 12 La v lvula de entrada est atascada est cerrada 13 El motor ha perdido compresi n 1 Gire la v lvula del combust...

Page 45: ...so indebido o negligente un mantenimiento inadecuado o modificaciones no autorizadas Usted es responsable de presentar su motor equipo a un centro de distribuci n de B S distribuidor autorizado de ser...

Page 46: ...entes relacionados con el sistema de emisiones cubiertos por la garant a que no sean originales de B S ni a los fallos debidos a uso indebido negligencia o mantenimiento inadecuado conforme a las disp...

Page 47: ...l mantenimiento de las constantes vitales Esta garant a excluye los fallos debidos a hechos fortuitos y a otros acontecimientos de fuerza mayor que escapan al control del fabricante 198189S Rev C 11 2...

Page 48: ...componentes del motor filtro de aire escape carga refrigeraci n carburador bomba de combustible etc limitaciones de la aplicaci n condiciones ambientales de uso temperatura humedad altitud y variacio...

Reviews: