Storage

The generator should be started at least once every seven
days and allowed to run at least 30 minutes. If this cannot be
done and you must store the unit for more than 30 days, use
the following guidelines to prepare it for storage.

Generator Storage

• Clean the generator as outlined in 

Cleaning

.

• Check that cooling air slots and openings on generator

are open and unobstructed.

Long Term Storage Instructions

Fuel can become stale when stored over 30 days. Stale fuel
causes acid and gum deposits to form in the fuel system or
on essential carburetor parts. To keep fuel fresh, use Briggs
& Stratton FRESH START® fuel stabilizer, available as a
liquid additive or a drip concentrate cartridge.

There is no need to drain gasoline from the engine if a fuel
stabilizer is added according to instructions. Run the engine
for 2 minutes to circulate the stabilizer throughout the fuel
system. The engine and fuel can then be stored up to
24 months.

If gasoline in the engine has not been treated with a fuel
stabilizer, it must be drained into an approved container. Run
the engine until it stops from lack of fuel. The use of a fuel
stabilizer in the storage container is recommended to
maintain freshness.

Change Engine Oil

While engine is still warm, drain oil from crankcase. Refill
with recommended grade. See 

Changing Engine Oil

.

Other Storage Tips

1. DO NOT store fuel from one season to another unless it

has been treated as described in 

Long Term Storage

Instructions

.

2. Replace fuel container if it starts to rust. Rust and / or

dirt in fuel can cause problems if it’s used with this
unit.

3. Cover unit with a suitable protective cover that does not

retain moisture.

4. Store generator in clean, dry area.

WARNING   

Fuel and its vapors are extremely flammable

and explosive which could cause burns,
fire or explosion resulting in death,
serious injury and/or property damage.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK

• Store away from furnaces, stoves, water heaters, clothes dryers

or other appliances that have pilot light or other ignition source
because they could ignite fuel vapors.

WHEN DRAINING FUEL

• Turn generator engine OFF and let it cool at least 2 minutes

before removing fuel cap. Loosen cap slowly to relieve pressure
in tank.

• Drain fuel tank outdoors.

• Keep fuel away from sparks, open flames, pilot lights, heat, and

other ignition sources.

• Check fuel lines, tank, cap and fittings frequently for cracks or

leaks. Replace if necessary.

• DO NOT light a cigarette or smoke.

WARNING   

Storage covers could cause a fire

resulting in death, serious injury and/or property
damage.

• DO NOT place a storage cover over a hot generator.

• Let equipment cool for a sufficient time before placing the

cover on the equipment.

Not 

for  

Reproduction

Summary of Contents for PowerBoss

Page 1: ...BRIGGS STRATTON POWER PRODUCTS GROUP LLC MILWAUKEE WISCONSIN U S A Manual No 313733GS Revision Inverter Generator Operator s Manual N o t f o r R e p r o d u c t i o n...

Page 2: ...ore attempting to start or operate this equipment Save these instructions for future reference This generator requires final assembly before use Refer to the Assembly section of this manual for instru...

Page 3: ...ceptacles 10 Operation 11 Starting the Engine 11 Connecting Electrical Loads 11 Stopping the Engine 12 POWERSMART Mode 12 Charging a Battery 12 Don t Overload Generator 13 Maintenance 14 Maintenance S...

Page 4: ...a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all inclusive If you use a procedure work method or operating technique that the manufacturer does n...

Page 5: ...ve OFF DO NOT tip engine or equipment at angle which causes fuel to spill Disconnect spark plug wire WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK Store away from furnaces stoves water heaters clot...

Page 6: ...le standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator WARNING Exhaust heat gases could ignite combustibles str...

Page 7: ...Fuel Fuel must meet these requirements Clean fresh unleaded gasoline A minimum of 87 octane 87 AKI 91 RON For high altitude use see High Altitude Gasoline with up to 10 ethanol gasohol or up to 15 MTB...

Page 8: ...s that the AC stator winding is isolated from the grounding fastener and the AC receptacle ground pins On a floating neutral generator the AC receptacle ground pins are not functional Electrical devic...

Page 9: ...eceptacle is protected by a push to reset circuit breaker J Grounding Fastener Consult your local agency having jurisdiction for grounding requirements in your area K POWERSMART Switch Use this switch...

Page 10: ...and push the button in to reset the circuit breaker This receptacle allows you to recharge a 12 Volt automotive or utility style storage battery with the battery charge cable provided This receptacle...

Page 11: ...o Run position and crank until engine starts NOTICE If engine starts after 3 pulls but fails to run or if unit shuts down during operation make sure unit is on a level surface and check for proper oil...

Page 12: ...ent caps make sure they are installed and are tight 4 Connect battery charge cable clamp with red handle to battery post or terminal indicated by Positive POS or 5 Connect battery charge cable clamp w...

Page 13: ...ze engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load NEVER add mo...

Page 14: ...aves or any other foreign material NOTICE DO NOT use water or other liquids to clean generator Liquids can enter engine fuel system causing poor performance and or failure to occur In addition if liqu...

Page 15: ...eratures Use of synthetic oil does not alter required oil change intervals Checking Oil Level Oil level should be checked prior to each use or at least every 8 hours of operation Keep oil level mainta...

Page 16: ...if you run it with a dirty air cleaner Service more often if operating under dirty or dusty conditions To service the air cleaner follow these steps 1 Loosen the side maintenance cover screws and rem...

Page 17: ...er screen 3 Inspect screen and obtain a replacement if torn perforated or otherwise damaged DO NOT use a defective screen If screen is not damaged clean it with a brush 4 Reattach screen to muffler Re...

Page 18: ...from crankcase Refill with recommended grade See Changing Engine Oil Other Storage Tips 1 DO NOT store fuel from one season to another unless it has been treated as described in Long Term Storage Ins...

Page 19: ...to Off 2 Fuel cap vent lever is in Off position 3 Low oil indicator light comes on Low oil level 4 Dirty air cleaner 5 Out of fuel 6 Stale fuel 7 Spark plug wire not connected to spark plug 8 Bad spa...

Page 20: ...enienced Any Authorized Service Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may not be appropriate For example warranty...

Page 21: ...21 N o t f o r R e p r o d u c t i o n...

Page 22: ...22 www 1800generator com au N o t f o r R e p r o d u c t i o n...

Page 23: ...23 N o t f o r R e p r o d u c t i o n...

Page 24: ...utomotive Engineers code J1940 Small Engine Power Torque Rating Procedure and rating performance has been obtained and corrected in accordance with SAE J1995 Revision 2002 05 Torque values are derived...

Reviews: