Page 1: ...azards Obey all safety messages that follow this symbol to avoid possible injury or death Questions Help is just a moment away Call Generac Generator Helpline 1 800 270 1408 M F 8 5 CT Web www generac portables com or www briggsandstratton com Model No 1642 1 5 500 Watt AC Generator Manual No 189438 Revision 2 02 I 1 2002 ...

Page 2: ...s used with a signal word DANGER CAUTION WARNING a pictorial and or a safety messageto alert you to hazards DANGER indicates a hazard which if not avoided will result in death or serious injury WARNING indicatesa hazard which if not avoided could result in death or serious injury CAUTION indicates a hazard which if not avoided might result in minor or moderate injury CAUTION when used without the ...

Page 3: ...y Wear protective goggles rubber apron and rubber gloves WARNING Do not touch hot surfaces Allow equipment to cool before touching CAUTION Do not tamper with governed speed Generator supplies correct rated frequency and voltage when running at governed speed Do not modify generator in any way CAUTION See Don t Overload Your Generator on page9 Start generator and let engine stabilize before connect...

Page 4: ...e May be usedto supply electrical power for the operation of 120and or 240Volt AC 30Amp single phase 60 Hz electrical lighting appliance tool and motor loads Air Cleaner Uses a dry type filter element to limit the amount of dirt and dust sucked into the engine Choke Lever Used when starting a cold engine 120Volt AC 20 Amp Duplex Receptacles Oil Fill Circuit Breakers AC Pushto reset circuit breaker...

Page 5: ... of carton down flat Remove all packing material carton fillers etc Remove the generator from the shipping carton CARTON CONTENTS Check all contents If any parts are missing or damaged call the generator helpline at 1 800 270 1408 The generator Generator and engine owner s manuals Locking 30Amp plug Engineoil Wheel kit INSTALL WHEEL KIT IMPORTANT This wheel kit is not intended for over the road us...

Page 6: ...ricated and sealed bali bearing that requires no additional lubrication for the life of the bearing Add Gasoline _ ARNING Never fill fuel tank indoors Never fill fuel tank when engine is running or hot Allow unit to cool for two minutes before refueling Do Not lighta cigarette or smoke when filling the fuel tank _ WARNING Do Not overfill the fuel tank Always allow room for fuel expansion Use regul...

Page 7: ...trical shock if aground fault condition exists in the generator or in connected electrical devices Proper grounding also helps dissipate static electricity which often builds up in ungrounded devices OPERATING THE G EN ERATO R _ AUTION Never start or stop the engine with electrical loadsconnected to the receptaclesAND with the connected devices turned ON Starting the Engine Disconnect alt electric...

Page 8: ...an use the same 4 wire cord if you _lanto run a 120Volt load NEMA LI4 30 Neutral Y Hot X Hot 77_ Ground Green This receptacle powers 120 240Volt AC 60 Hz single phase loads requiring up to 5 500 watts of power 5 5 kW at 30 Amps for 120Volts or 240Volts The outlet is protected by a push to reset circuit breaker _ CAUTION Although this outlet states it has a 120 240Volt 30 Amp rating up to 7 200 wat...

Page 9: ...ator power is to sequentially add loadsas follows I With nothingconnected to the generator start the engine as described in this manual 2 Plugin and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat st...

Page 10: ... laboratory animals Thoroughly wash exposed areas with soap and water KEEPOUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Generator Maintenance Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture or any corrosive vapors Cool...

Page 11: ...that cooling air slots and openings on generator are open and unobstructed _ AUTION Storage covers can be flammable Oo Not place a storage cover over a hot generator Let the unit cool for a sufficient time before placing the cover on the unit Engine Storage Seeengine owner s manual for instructions Other Storage Tips Do Not store gasoline from one seasonto another Replacegasoline can if it starts ...

Page 12: ...is ingood condition 4 Contact Generac service facility I Disconnect shorted electrical load 2 See Don t Overload the Generator on page9 3 Contact Briggsservice facility 4 Contact Generac service facility I Set switch to On 2 Turn fuel valveto the Open position 3 Fill crankcaseto proper level 4 Clean or replace air cleaner 5 Fill fuel tank 6 Drain gastank and fill with fresh fuel 7 Connect wire to ...

Page 13: ...NOTES 13 ...

Page 14: ...ATIC BLUE BLUE ii C B BLUE 114 BRIOGE RECTIFIER BLUE_ 6 I EXCITATION FIELD RED GRAY 44 RED GR4Y 22 44 120V 204 GRAY 444 BLUE 4 __BLUE 114 BLUE I14 RED 22 RED 22 0 I BLUE I14 m 12o e4ov 3o4 R_ GR4Y 444 22 I 14 ...

Page 15: ..._ 120 24 11A 22 SIX LUG CONNECTOR HBUSING D CIRCUIT BREAKER IIA 44A 11A IIA IBOV 20A NOTE POSITIVE BRUSH IS CLOSEST TO BEARING _ _ BLUE I RED 2 6 l 88 rCARNING TAB MUST NOT BE BROKEN CUSTOMER GRBUNB LUO RED 22 BLUE _ 11 BlX LUO CONNECTOR HOUSINO 15 ...

Page 16: ...EXPLODED VIEW 43 57 44 56 MAIN UNIT 69 41 42 59 65 29 62 _ 15 27 52 57 74 8 11 _28 _49 71_ 48 35 lO 5 25 55 46 _47 21 67 16 ...

Page 17: ...gine ASSEMBLY Brush Holder TAPTITE M5 0 8 x 16 COVER Bearing Carrier WASH ER 10 Ext Shakeproof SCREW M6 1 0 x 16Wing Item Part Qty 37 B2153GS 4 38 189155GS 4 39 188973GS 4 40 189156GS 4 41 80270GS I 42 78299GS I 43 85134GS I 44 188817GS I 45 189235GS I 46 22097GS 4 47 22127GS 4 48 14353621GS I 49 26850GS 2 50 B4986GS I 51 92982GS I 52 189153GS I 53 B5072GS 4 54 BB3061GS 55 187330GS 56 189025GS 57 ...

Page 18: ...217GS 2 BI764GS 3 52858GS 4 39287GS 5 93693HGS 6 B4966GS 7 87005AGS 8 22247GS 9 42907GS Qty Description I ASSEMBLY Handle I LEG Mounting 4 NUT Locking Hex M8 1 25 2 HHCS M8 1 25 x 45 I AXLE 2 WHEEL 10 Diameter 2 PIN Retaining 2 WASHER Flat 2 HHCS M8 1 25x 16 18 ...

Page 19: ... 82308GS 16 22694GS Qty Description I COVER Lid Control Panel I CONTROL PANEL Compact 2 CLIP Hinge Pin Retainer 2 SPRING Hinge Pin 2 PIN Hinge Cover Compact 2 OUTLET 120V 20Amp Duplex 4 NUT Patnut Pushnut 5 32 2 CAP Circuit Breaker 2 CIRCUIT BREAKER I OUTLET 120 240 Locking 30A 2 NUT Patnut Pushnut 3 16 2 SCREW Phillips Head 3 5 x 18 I BAR Retaining I COVER Back Control Panel 6 SCREW SelfTapping S...

Page 20: ... PRECAUCI6N un mensaje por escrito o una ilustracibn para alertarlo acerca de cualquier situacibn de peligro que pueda existir PELIGRO indicaun riesgo el cual si no se evita causar_la muerte o una herida grave ADVERTENCIA indica un riesgo el cual si no se evita puede causar la muerte o una herida grave PRECAUCI_ N indica un riesgo el cual si no se evita puede causar heridas menores o moderadas PRE...

Page 21: ...as galas protectoras delantal y guantes de gorna ADVERTENCIA No toque las superficies calientes Permita que el equipo se enfrle antes de tocarlo PRECAUCION No cambie ninguna velocidad determinada El generador suministra una frecuencia y un voltaje calificado cuando funciona a una velocidad determinada No modifique al generador en ninguna forma PRECAUCION Vea No sobrecargue su generador en la p_gin...

Page 22: ...ancin Deber_ estar en la posici6n On En para darle arranque al moton Col6quelo en la posici6n Oft Apagado para detener un motor en funcionamiento Palanca del Cebador Us_dacuando se est_ dando arranque a un motor frio Sileneiador Apagachispas El silenciador disminuye el ruido del motor y est_ equipado con una pantalla apagachispas Tanque del Combustible El tanque tiene una capacidad de 5 galones am...

Page 23: ...ialguna de las partes no est_ presente o es_ da_ada por favor Ilame a la linea de ayuda para generadores al 1 800 270 1408 La unidad principal Manual del propietario Aceite para motor Tapones de fijaci6n Juego de Ilantas INSTALE EL JUEGO DE RUEDAS IMPORTANTE EsteJuego de Ruedas no ha sidodisehado para ser usado en la cari_etera Para instalarsu Juego de Ruedas usted necesitar_ las siguientes herram...

Page 24: ...anque del combustible cuando el motor est_ en funcionamiento o caliente No encienda dgarrillos o fume cuando est_ Ilenando el tanque del combustible _ iADVERTENClA No Ilene excesivamente el tanque de combustible Deje suficiente espacio para la expansi6n del combustible Use gasolina regular SIN CONTENIDO DE PLOMO en el generador No use gasolina premium No mezde aceite con gasolina Limpie el _rea al...

Page 25: ...al se acumula frecuentemente en dispositivos no conectados a tierra OPERANDO EL GENERADOR _1 iPRECAUCI_N Nunca encienda o pare el motor con las cargasel_ctricas conectadasa los recept_culosY con los aparatos conectados ENCENDIDOS Encienda el Motor Desconecte todas las cargasel_ctricasdel generador Use las siguientes instrucciones para encender paso por paso en orden num_rico I Gire la v_lvula del ...

Page 26: ...cable de 4 alambres si planeatrabajar con una carga de 120Voltios Este recept_culo le provee poder a cargasde 120 240VoltiosAC de 60 Hz fasesencilla que requieren hasta 5 500 vatios de energia 5 5 kW a 30Amps para 120Voltioso 240Voltios La salida est_ protegida por un corto circuito de del tipo empuje para reposicionar _ PRECAUCI_N Aunque esta salidatiene una clasificaci6n de 120 240Voltios 30Amps...

Page 27: ...aslas cargas como se describe a continuaci6n I Sin tener nada conectado al generador encienda el motor de la manera descrita en este manual 2 Conecte y encienda la primera carga preferiblemente la mayor que usted tenga 3 Permita que la salidadel generador se estabilice el motor funciona suavemente y el aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la pr6xima carga 5 De nuev...

Page 28: ...odria introducirseen el sistema de combustible del motor y causar problemas Adem_s si el agua se introduce al generador a trav6s de las ranuras para aire de enfriamiento algo del agua quedar_ retenida en los espacios vactosy grietas del aislamiento del devanado del estator y rotor La acumulacibn de aguay suciedad en los devanados internos del generador disminuir_ eventualmente la resistencia del a...

Page 29: ...NOTAS I 29 ...

Page 30: ...tmento de Servicio Generac I Desconecte la carga el_ctrics en corto 2 Ves No Sobrerecarque el Generador en la p_gins 27 3 Contacte el Departmento de Servicio Briggs and Stratton 4 Contacte el Departmento de Servicio Generac I Coloque delinterruptor en On 2 Gire la v_lvula del combustible a la posicibn OIFI 3 Limpie o reemplace el depurador de aire 4 Ll_nelo con combustible fresco 5 Drene el tanque...

Page 31: ...iA LA FECHA DE LA FABRICACI _N DEL EQUIPO SERA USADA PARA DETERMINAR EL PERIODO DE GARANTiA Ace_a de la seguridad de su equipo Los Productos Port tiles Generac reciben las reparaciones bajo la garantia y le pide disculpas por cualquierinconveniencia causada Cualquier Concesionario de Servicio Autorizado puede Ilevar a czbo reparaciones baio la garantia La mayorla de las reparaciones baio la garant...

Page 32: ...DO NOT PROVIDE PROOF OFTHE INITIAL PURCHASE DATE ATTHETIME WARRANTY SERVICE IS REQUESTED THE MANUFACTURING DATE OFTHE EQUIPMENTWILL BE USEDTO DETERMINE THE WARRANTY PERIOD About your equipment warranty Generac PortableProductswelcomeswarranty repair and apologizesto you for being inconvenienced Any Authorized ServiceDealer mayperform warranty repairs Most warranty repairs are handled routinely but...

Reviews: