background image

3

SAFETY RULES

8000W Portable Generator

PowerBOSS™

3

• When using generator for backup power, notify utility

company. Use approved transfer equipment to isolate
generator from electric utility.

• DO NOT touch bare wires or receptacles.
• DO NOT use generator with electrical cords which are worn,

frayed, bare or otherwise damaged.

• DO NOT operate generator in the rain.
• DO NOT handle generator or electrical cords while standing

in water, while barefoot, or while hands or feet are wet.

• DO NOT allow unqualified persons or children to operate or

service generator.

Generator produces powerful voltage.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.

WARNING

• This generator does not meet U. S. Coast Guard Regulation

33CFR-183 and should not be used on marine applications.

• Failure to use the appropriate U. S. Coast Guard approved

generator could result in bodily injury and/or property
damage.

WARNING

WHEN ADDING OR DRAINING FUEL
• Turn generator OFF and let it cool at least 2 minutes before

removing fuel cap. Loosen cap slowly to relieve pressure in
tank.

• Fill or drain fuel tank outdoors.

• DO NOT overfill tank. Allow space for fuel expansion.

• Keep fuel away from sparks, open flames, pilot lights, heat, and

other ignition sources.

• DO NOT light a cigarette or smoke.

WHEN STARTING EQUIPMENT
• Ensure spark plug, muffler, fuel cap and air cleaner are in place.

• DO NOT crank engine with spark plug removed.

• If fuel spills, wait until it evaporates before starting engine.

WHEN OPERATING EQUIPMENT
• Do not tip engine or equipment at angle which causes fuel to

spill.

• This generator is not for use in mobile equipment or marine

applications.

WHEN TRANSPORTING OR REPAIRING
EQUIPMENT
• Transport/repair with fuel tank EMPTY or with fuel shutoff

valve OFF.

• Disconnect spark plug wire.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL
IN TANK
• Store away from furnaces, stoves, water heaters, clothes

dryers or other appliances that have pilot light or other
ignition source because they can ignite fuel vapors.

Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.

WARNING

• Operate generator ONLY outdoors.

• Keep exhaust gas from entering a confined area through

windows, doors, ventilation intakes or other openings.

• DO NOT operate generator inside any building or enclosure,

including the generator compartment of a recreational vehicle (RV).

Running generator gives off carbon monoxide,
an odorless, colorless, poison gas.
Breathing carbon monoxide will cause nausea,
fainting or death.

WARNING

Summary of Contents for PowerBoss 030228

Page 1: ...a Generador Helpline 1 800 743 4115 M F 8 5 CT web www briggsandstratton com PowerBOSS is a trademark of Briggs Stratton Power Products PowerBOSS es una marca registrada de Briggs Stratton Power Produ...

Page 2: ...e owner s manual SAFETY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or...

Page 3: ...low space for fuel expansion Keep fuel away from sparks open flames pilot lights heat and other ignition sources DO NOT light a cigarette or smoke WHEN STARTING EQUIPMENT Ensure spark plug muffler fue...

Page 4: ...tor if electrical output is lost equipment sparks smokes or emits flames unit vibrates excessively Improper treatment of generator can damage it and shorten its life CAUTION WHEN ADJUSTING OR MAKING R...

Page 5: ...ts engine by filtering dust and debris out of intake air Battery Float Charger Use battery float charger jack to keep the starting battery charged and ready for use Choke Lever Used when starting a co...

Page 6: ...is kit Refer to Figure 1 and install the wheel kit as follows 1 Place generator on a hard flat surface 2 Stand at control panel end of generator and gently tilt generator up high enough to place woode...

Page 7: ...nerator assembly rotates on a prelubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing Add Fuel NOTE This gasoline engine is certified to operate on ga...

Page 8: ...lace generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes or other...

Page 9: ...sing any 12Volt automotive or utility style storage battery 1 Unscrew fuse holder and remove generator s 10 Amp in line fuse Figure 8 Verify fuse is good or replace with a known good fuse Reinstall fu...

Page 10: ...desired 120 and or 240 Volt AC single phase 60 Hz electrical loads DO NOT connect 240 Volt loads to the 120 Volt receptacles DO NOT connect 3 phase loads to the generator DO NOT connect 50 Hz loads t...

Page 11: ...is exposed as shown in Figure 11 IMPORTANT The generator must be at least 5 ft 152 cm from structures having combustible walls and or other combustible materials Leave at least 3 ft 92 cm all around...

Page 12: ...a 4 wire cord set rated for 250 Volt AC loads at 30 Amps or greater Figure 13 You can use the same 4 wire cord if you plan to run a 120 Volt load This receptacle powers 120 240 Volt AC 60 Hz single ph...

Page 13: ...is protected by a 30 Amp push to reset circuit breaker 120 Volt AC 20 Amp Duplex Receptacle Each receptacle Figure 15 is protected against overload by a 20 Amp push to reset circuit breaker Use each r...

Page 14: ...generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each...

Page 15: ...on if water enters generator through cooling air slots some of the water will be retained in voids and cracks of the rotor and stator winding insulation Water and dirt buildup on the generator interna...

Page 16: ...nt gum from forming in fuel system or on essential carburetor parts add fuel stabilizer into fuel tank and fill with fresh fuel Run the unit for several minutes to circulate the additive through the c...

Page 17: ...is in good condition Generator runs good at no load but bogs down when loads are connected 1 Short circuit in a connected load 2 Generator is overloaded 3 Shorted generator circuit 1 Disconnect shorte...

Page 18: ...18 PowerBOSS 8000W Portable Generator NOTES NOTES...

Page 19: ...sed for commercial purposes are not warranted NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS STRATTON PRODUCTS SAVE YOUR PROOF OF PURCHASE RECEIPT IF YOU DO NOT PROVIDE PROOF OF TH...

Page 20: ...Agencia de Protecci n Ambiental Para mayor informaci n acerca de la garant a consulte con el manual del propietario del motor REGLAS DE SEGURIDAD ste es el s mbolo de alerta de seguridad Sirve para ad...

Page 21: ...EQUIPO NO incline el motor o el equipo de tal manera que la combustible se pueda derramar Este generador no es apto para el uso en equipos m viles ni en aplicaciones marinas CUANDO TRANSPORTE O REPAR...

Page 22: ...el generador Apague el generador si Se pierde la salida el ctrica El equipo produce chispas humo o emite llamas La unidad vibra de una manera excesiva El tratamiento inadecuado del generador puede da...

Page 23: ...el ctrica para el funcionamiento de cargas del motor herramientas aparatos especiales e iluminaci n el ctrica de 120Voltios AC a 20 Amperios monof sica de 60 Hz Tomacorriente con Dispositivo de Seguri...

Page 24: ...sobre una superficie plana y dura 2 P rese en el extremo del motor del generador e incline el generador cuidadosamente hacia adelante lo suficiente como para colocar bloques por debajo del armaz n Est...

Page 25: ...icional por la vida til del cojinete Agregue Combustible NOTA Este motor est certificado para funcionar con gasolina Sistema de control de emisiones de gases de escape EM Modificaciones del motor 1 Ut...

Page 26: ...io que pueda estar ocupado Aseg rese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaci n u otras aberturas en un espacio cerrado en el que puedan acumularse F...

Page 27: ...idad puede equiparse con un dispositivo de protecci n de bajo nivel de aceite Vea manual de motor Figura 23 Interruptor Ignici n V lvula del Combustible en posici n On Figura 21 V lvula de Combustible...

Page 28: ...rojo para volver a cubrir el terminal POSITIVO de la bater a Si tiene alguna pregunta llame a la l nea de asistencia t cnica de generadores al 1 800 743 4115 de lunes a viernes y de 8 00 a 17 00 horar...

Page 29: ...ceite diariamente o despu s de cada ocho 8 horas de funcionamiento 5 Mantenga el generador que sigue el Horario de la Conservaci n en el manual de motor 6 Proteja la unidad de la intemperie En caso de...

Page 30: ...ECEPT CULOS 240 Voltios AC 50 Amperios Recept culo Use un tap n NEMA 14 50 con este recept culo Conecte un juego de cable de 4 alambres clasificado como 250 Voltios AC a 50 Amperios o mayor Figura 28...

Page 31: ...hufe Figura 30 Utilice este tomacorriente para operar cargas el ctricas de 120Voltios AC monof sicas de 60 Hz que requieran hasta 3 600 vatios 3 6 kW a 30 Amperios de corriente La toma est protegida p...

Page 32: ...r funciona suavemente y el aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada c...

Page 33: ...irse en el sistema de combustible del motor y causar problemas Adem s si el agua se introduce al generador a trav s de las ranuras para aire de enfriamiento algo del agua quedar retenida en los espaci...

Page 34: ...enando Para prevenir que se forme una resina en el sistema de combustible o en partes esenciales del carburador vac e estabilizadores del combustible suministrados en el tanque de gasolina y llene con...

Page 35: ...orizado El motor funciona bien sin carga pero funciona mal cuando se le contectan cargas 1 Corto circuito en una de las cargas conectadas 2 El generador est sobrecarga 3 Circuito del generador en cort...

Page 36: ...ON PRODUCTS GUARDE SU RECIBO DE COMPRA SI NO APORTA LA PRUEBA DE LA FECHA DE COMPRA INICIAL SE UTILIZAR LA FECHA DE FABRICACI N DEL PRODUCTO PARA DETERMINAR EL PER ODO DE GARANT A ACERCA DE LA EQUIPO...