Generac Portable Products 3250 Watt Generator
10
TROUBLESHOOTING
Problem
Cause
Solution
Engine is running, but
no AC output is
available.
1. Circuit breaker is open.
2. Poor connection or defective cord set.
3. Connected device is bad.
4. Fault in generator.
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is in good
condition.
4. Contact Generac service facility.
Engine runs good but
bogs down when
loads are connected.
1. Short circuit in a connected load.
2. Generator is overloaded.
3. Engine speed is too slow.
4. Shorted generator circuit.
1. Disconnect shorted electrical load.
2. See “Don’t Overload the Generator” on
page 8.
3. Contact Briggs and Stratton service
facility.
4. Contact Generac service facility.
Engine will not start;
or starts and runs
rough.
1. Rocker switch set to “Off”.
2. Fuel valve is in the “Off” position.
3. Dirty air cleaner.
4. Out of gasoline.
5. Stale
gasoline.
6. Spark plug wire not connected to
spark plug.
7. Bad spark plug.
8. Water
in
gasoline.
9. Overchoking.
10. Low oil level.
11. Excessively rich fuel mixture.
12. Intake valve stuck open or closed.
13. Engine has lost compression.
1. Set switch to “On”.
2. Turn fuel valve to the “On” position.
3. Clean or replace air cleaner.
4. Fill fuel tank.
5. Drain gas tank and fill with fresh fuel.
6. Connect wire to spark plug.
7. Replace spark plug.
8. Drain gas tank; fill with fresh fuel.
9. Set choke to Run position.
10. Fill crankcase to proper level.
11. Contact Briggs and Stratton service
facility.
12. Contact Briggs and Stratton service
facility.
13. Contact Briggs and Stratton service
facility.
Engine shuts down
during operation.
1. Out of gasoline.
2. Fault in engine.
1. Fill fuel tank.
2. Contact Briggs and Stratton service
facility.
Engine lacks power.
1. Load is too high.
2. Dirty
air
filter.
3. Engine needs to be serviced.
1. See “Don’t Overload the Generator” on
page 8.
2. Replace
air
filter.
3. Contact Briggs and Stratton service
facility.
Engine “hunts” or
falters.
1. Choke is opened too soon.
2. Carburetor is running too rich or too
lean.
1. Move choke to halfway position till engine
runs smoothly.
2. Contact Briggs and Stratton service
facility.
Summary of Contents for GENERAC 1653-0
Page 11: ...Generac Portable Products 3250 Watt Generator 11 SCHEMATIC AND WIRING DIAGRAM...
Page 12: ...Generac Portable Products 3250 Watt Generator 12 EXPLODED VIEW MAIN UNIT...
Page 24: ...Generac Portable Products 3250 Generador de Vatio 24 NOTAS...
Page 26: ...Generac Portable Products 3250 Generador de Vatio 26 NOTAS...