background image

8000W Portable Generator

15

SPECIFICATIONS

Starting Wattage  . . . . . . . . . . . . . . . . . . . . . . . .13,500 watts
Wattage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8,000 watts
AC Load Current:

At 120 Volts  . . . . . . . . . . . . . . . . . . . . . . . . . . .66.6 Amps
At 240 Volts  . . . . . . . . . . . . . . . . . . . . . . . . . . .33.3 Amps

Phase  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase
Rated Frequency  . . . . . . . . . . . . . . . . . . . . . . . . . . .60 Hertz
Fuel Tank Capacity . . . . . . . . . . . . . . . . . . . . . . .7 U.S. gallons
Shipping Weight  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198 lbs.

GENERAL MAINTENANCE

RECOMMENDATIONS

The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. NEVER operate a
damaged or defective generator.

Engine Maintenance

See engine operator’s manual for instructions.

KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.

Generator Maintenance

Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.

NOTE: DO NOT use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air slots,
some of the water will be retained in voids and cracks of
the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.

Battery Maintenance

Other than float charging, described elsewhere, no
maintenance is required for the starting battery. Keep the
battery and terminals clean and dry.

IMPORTANT: Battery charging should be performed in a
dry location, such as inside a garage.

Generator Cleaning

• Use a damp cloth to wipe exterior surfaces clean.

• Use a soft bristle brush to loosen caked on dirt or oil.
• Use a vacuum cleaner to pick up loose dirt and debris.
• Use low pressure air (not to exceed 25 psi) to blow

away dirt. Inspect cooling air slots and opening on
generator.These openings must be kept clean and
unobstructed.

• Used motor oil has been shown to cause skin cancer in

certain laboratory animals.

• Thoroughly wash exposed areas with soap and water.

Avoid prolonged or repeated skin contact with used
motor oil.

CAUTION

• DO NOT expose generator to excessive moisture, dust, dirt,

or corrosive vapors.

• DO NOT insert any objects through cooling slots.

Improper treatment of generator can damage it and
shorten its life.

CAUTION

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR
• Disconnect the spark plug wire from the spark plug and place

the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK
• Use approved spark plug tester.

• DO NOT check for spark with spark plug removed.

Unintentional sparking can result in fire or
electric shock.

WARNING

Summary of Contents for Elite 030210-2

Page 1: ...or 1 800 743 4115 M F 8 5 CT web www briggsandstratton com Before using this product read this manual and follow all Safety Rules and Operating Instructions WARNING Antes de utilizar el producto lea e...

Page 2: ...y information refer to the engine operator s manual SAFETY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this...

Page 3: ...n odorless colorless poison gas Breathing carbon monoxide can cause nausea fainting or death WARNING WHEN ADDING OR DRAINING FUEL Turn generator OFF and let it cool at least 2 minutes before removing...

Page 4: ...equipment sparks smokes or emits flames unit vibrates excessively Improper treatment of generator can damage it and shorten its life CAUTION WHEN ADJUSTING OR MAKING REPAIRS TOYOUR GENERATOR Disconnec...

Page 5: ...The 120Volt AC 20A duplex receptacles are provided with push to reset circuit breakers to protect the generator against electrical overload Data Tag Provides model revision and serial number of gener...

Page 6: ...ngine operator s manual Battery float charger Wheel kit If any parts are missing or damaged call the generator helpline at 1 800 743 4115 ELECTRIC START Your unit is equipped with electric start capab...

Page 7: ...e an e ring in axle groove 5 Install e ring with pliers squeezing from top of e ring to bottom of axle 6 Repeat step 3 thru 5 to secure second wheel 7 Tip generator so that engine side is down 8 Attac...

Page 8: ...gular unleaded fuel to fuel tank Be careful not to overfill Allow about 1 5 of tank space for fuel expansion Figure 3 4 Install fuel cap and wipe up any spilled fuel CAUTION Refer to engine operator s...

Page 9: ...llect in a confined area Figure 4 Prevailing winds and air currents should be taken into consideration when positioning generator Figure 4 Generator Clearance Exhaust Port Typical Generator Shown When...

Page 10: ...ee Don t Overload Generator Start generator and let engine stabilize before connecting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF an...

Page 11: ...requiring up to 7 200 watts of power 7 2 kW at 30 Amps for 240 Volts or two independent 120 Volt loads at 30 Amps each The outlet is protected by a 30 Amp rocker switch circuit breaker 120 Volt AC 20...

Page 12: ...izer and will not overcharge the battery even when plugged in for an extended period of time IMPORTANT See Battery Maintenance on page 15 for additional information COLD WEATHER OPERATION Under certai...

Page 13: ...sure muffler side of generator is exposed NOTE Structure should hold enough heat created by the generator to prevent icing problem 2 DO NOT enclose generator any more than shown in Figure 9 NOTE If a...

Page 14: ...r output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additiona...

Page 15: ...d stator winding insulation Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings Battery Maintenance Other than float charging...

Page 16: ...rom forming in fuel system or on essential carburetor parts add fuel stabilizer into fuel tank and fill with fresh fuel Run the unit for several minutes to circulate the additive through the carbureto...

Page 17: ...wn when loads are connected 1 Short circuit in a connected load 2 Generator is overloaded 3 Shorted generator circuit 1 Disconnect shorted electrical load 2 See Don t Overload Generator 3 Contact Auth...

Page 18: ...18 8000W Portable Generator NOTES...

Page 19: ...ectric powered pressure washers used for commercial purposes are not warranted NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS STRATTON PRODUCTS SAVE YOUR PROOF OF PURCHASE RECEIPT...

Page 20: ...e Protecci n Ambiental y el Consejo de recursos de aire de California Para mayor informaci n acerca de la garant a consulte con el manual del operario del motor REGLAS DE SEGURIDAD ste es el s mbolo d...

Page 21: ...a el silenciador el tap n del dep sito de combustible y el filtro de aire est n instalados NO arranque el motor sin la buj a instalada Si se ha derramado combustible espere a que se evapore antes de a...

Page 22: ...l equipo produce chispas humo o emite llamas La unidad vibra de una manera excesiva El tratamiento inadecuado del generador puede da arlo y acortar su vida productiva PRECAUCI N CUANDO AJUSTE O HAGA R...

Page 23: ...favor estos prontamente disponible cu ndo llamar para la ayuda Interruptor Balanc n Deber estar en la posici n On En para darle arranque al motor Col quelo en la posici n Off Apagado para detener un m...

Page 24: ...otor Manual del Operario Manual del Operario del Motor Corcel de Bater a Juego de Ruedas Si cualquier parte falta o est da ada llame a la L nea de Ayuda del Generador al 1 800 743 4115 ARRANQUE EL CTR...

Page 25: ...erior de la anilla en e hacia la parte inferior del eje 6 Repita los pasos del 3 al 5 para asegurar la segunda rueda 7 Dele la vuelta al generador de forma que el lado del motor quede abajo 8 Fije los...

Page 26: ...ene el tanque lentamente hasta aproximadamente 1 5 por debajo de la parte la cima del cuello del tubo de llenado Figura 13 4 Instale la tapa del tanque de combustible y limpie la combustible que se ha...

Page 27: ...n del generador Figura 14 Espacio Libre Alrededor del Generador Salida del Escape T pica Generador Mostrada Cuando use un generador como poder de energ a auxiliar notifique a la compa a de utilidades...

Page 28: ...FF luego encienda ON para su operaci n Apague OFF las cargas el ctricas y descon ctelas del generador antes de parar el generador El sobrepasar la capacidad del amperaje y vataje del generador puede d...

Page 29: ...vatios de energ a a 30 Amperios para 120 Voltios 7 200 vatios de energ a 7 2 kW a 30 Amperios para 240 Voltios El enchufe est protegido por un disyuntor basculante 120 Volt AC 20 Amp Recept culos Dobl...

Page 30: ...flotaci n que impide la sobrecarga de la bater a incluso aunque est enchufado durante un largo periodo de tiempo IMPORTANTE Para obtener m s informaci n al respecto consulte Mantenimiento de la Bater...

Page 31: ...l silenciador quede expuesto NOTA La estructura debe mantener una cantidad suficiente del calor disipado por el generador para evitar problemas de congelaci n 2 NO cierre el generador m s de lo que se...

Page 32: ...aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que usted te...

Page 33: ...al generador a trav s de las ranuras para aire de enfriamiento algo del agua quedar retenida en los espacios vac os y grietas del aislamiento del devanado del estator y rotor La acumulaci n de agua y...

Page 34: ...r la formaci n de carbonilla en el circuito de combustible o en piezas esenciales del carburador a ada estabilizador de combustible al dep sito de combustible y llene este de gasolina nueva Haga funci...

Page 35: ...orto circuito en una de las cargas conectadas 2 El generador est sobrecarga 3 Circuito del generador en corto 1 Desconecte la carga el ctrica en corto 2 Vea No Sobrerecarque Generador 3 Contacte el di...

Page 36: ...RVICIO DE BRIGGS STRATTON PRODUCTS GUARDE SU RECIBO DE COMPRA SI NO APORTA LA PRUEBA DE LA FECHA DE COMPRA INICIAL SE UTILIZAR LA FECHA DE FABRICACI N DEL PRODUCTO PARA DETERMINAR EL PER ODO DE GARANT...

Reviews: