background image

Not for 

Reproduction

 7

Installation

We sincerely appreciate your patronage. For this reason, we 
have made every effort to provide for a safe, streamlined 
and cost-effective installation. Because each installation is 
unique, it is impossible to know of and advise the trade of all 
conceivable procedures and methods by which installation 
might be achieved. Neither could we know of possible 
hazards and/or the results of each method or procedure. For 
these reasons,
Only current licensed electrical and plumbing professionals 
should attempt home generator system installations. 
Installations must strictly comply with all applicable codes, 
industry standards and regulations.
Your home generator is supplied with this “Operator’s 
Manual” and a separate “Installation Manual”. These are 
important documents and should be retained by the owner 
after the installation has been completed.
This product is only for use as an optional generator system 
which provides an alternate source of electric power and 
to serve loads such as heating, refrigeration systems, and 
communication systems that, when stopped during any 
power outage, could cause discomfort or inconvenience.  

NOTICE

   This product does NOT qualify for either an 

emergency standby or legally required standby system as 
defined by NFPA 70 (NEC).
 

•  Emergency generator systems are intended to 

automatically supply illumination, power, or both, to 
designated areas and equipment in the event of failure 
of the normal supply. Emergency systems may also 
provide power for such functions as ventilation where 
essential to maintain life, where current interruption 
of the normal supply would produce serious life 
safety or health hazards.

 

•  Legally Required standby generator systems are 

intended to automatically supply power to selected 
loads in the event of failure of the normal source 
which could create hazards or hamper rescue or fire-
fighting operations.

Every effort has been made to ensure that information in this 
manual is accurate and current. However, we reserve the 
right to change, alter, or otherwise improve the product and 
this document at any time without prior notice.
Only current licensed electrical and plumbing professionals 
should attempt home generator system installations. 
Installations must strictly comply with all applicable codes, 
industry standards, laws and regulations.

For the home Owner:

To help you make informed choices and communicate 

effectively with your installation contractor(s), 

read and 

understand 

Owner Orientation

 in this manual before 

contracting or starting your generator installation.

To arrange for proper installation, contact the store at which 

you purchased your generator, your dealer, a licensed 

electrician or your utility power provider.

The generator warranty is VOID unless the 

system is installed by licensed electrical and 

plumbing professionals.

Every effort has been made to ensure that information in this 

manual is accurate and current. However, we reserve the 

right to change, alter, or otherwise improve the product and 

this document at any time without prior notice.
The Emission Control System for this generator is warranted 

for standards set by the U.S. Environmental Protection 

Agency and by the California Air Resources Board (CARB).

For the Installing Dealer/Contractor:

For most applications, the installation manual contains 

all the information required to properly install and start 

the generator. This operator’s manual describes routine 

operation and owner maintenance procedures.
If you need more information in this matter, please call at 

800-732-2989 between 8:00 AM and 5:00 PM CT.

Owner Orientation

This section provides generator owners with the information 

necessary to achieve the most satisfactory and cost effective 

installation possible.
The illustrations are for typical circumstances and are meant 

to familiarize you with the installation options available 

with your generator. A thorough understanding of these 

options will provide fundamental control over the cost of 

your installation, as well as ensure your final satisfaction 

and security.
Federal and local codes, appearance, noise levels, fuel types, 

and distances are the factors that must be considered when 

negotiating with an installation professional. Remember 

that as the distance from the existing electrical service and 

gaseous fuel supply increases, and the number of 90 degree 

bends in the fuel supply increases, compensations in piping 

and wiring materials must be made. This is necessary to 

comply with local codes and overcome electrical voltage 

drops and gaseous fuel pressure drops.

The factors mentioned above will have a direct affect on 

the overall price of your generator installation.

In some areas you may need to acquire electrical permits 

for installing the generator, building permits for installing 

gas lines, and permits for noise allowances. Your installer 

should check your local codes AND obtain the permits before 

installing the system.

Summary of Contents for 040351

Page 1: ...N o t f o r R e p r o d u c t i o n Generator Systems Operator s Manual Generator System...

Page 2: ...nerator requires professional installation before use Refer to the separate installation manual for full information Your installer should follow the instructions completely Where to Find Us You never...

Page 3: ...Sequence 19 Setting Exercise Timer 20 Maintenance 21 Servicing the System 21 Service Code Detection System 21 Maintenance Schedule 23 Generator Maintenance 23 Engine Maintenance 24 Adjust Valve Lash...

Page 4: ...ziness vomiting confusion seizures nausea or fainting Operate this product ONLY outdoors in an area that will not accumulate deadly exhaust gas Keep exhaust gas away from any windows doors ventilation...

Page 5: ...ways set the generator s system switch to OFF remove the service disconnect from the disconnect box AND remove the 15 Amp fuse BEFORE working on the equipment WARNING Propane and Natural Gas are extre...

Page 6: ...d on generator DO NOT tamper with governed speed Generator supplies correct rated frequency and voltage when running at governed speed DO NOT modify generator in any way WARNING Exhaust heat gases cou...

Page 7: ...lp you make informed choices and communicate effectively with your installation contractor s read and understand Owner Orientation in this manual before contracting or starting your generator installa...

Page 8: ...of 2 5 and minimum propane content of 90 Natural gas rating will depend on specific fuel but typical derates are between 10 to 20 off the LP gas rating Natural gas or LP engines are certified to opera...

Page 9: ...positioning generator See the installation manual for full details on safe generator location WARNING Running engine gives off carbon monoxide an odorless colorless poison gas Breathing carbon monoxi...

Page 10: ...and your installer for claim procedures Missing or damaged parts are not warranted The home generator system is supplied with Oil 5W30 Synthetic Flexible steel fuel line Installation and start up man...

Page 11: ...h most residential codes C Alternator An electrical machine that generates an alternating current D Spark Plug A device in the cylinder head of the engine that ignites the fuel mixture by means of an...

Page 12: ...recleaner to protect engine by filtering dust and debris out of intake air F Control Panel Used for various test operation and maintenance functions See System Control Panel G Circuit Breaker Protects...

Page 13: ...rator is equipped with an enclosure that has several access panels as shown A Front Panel that is used to access Battery Compartment Engine Oil Drain Hose Engine Oil Filter Engine Valve Cover Spark Pl...

Page 14: ...the unit 2 Carefully lift and remove roof from unit To remove front panel 1 Remove the two screws B that secure the panel to the unit 2 Lift and flex panel outward and off base Use caution not to dama...

Page 15: ...he next utility outage OFF Turns off running generator prevents unit from starting and resets any detected service codes OFF must be pressed and held for more than 5 seconds in order to reset service...

Page 16: ...PUT UNIT INTO AUTOMATIC MODE IF A UTILITY POWER OUTAGE IS SENSED THE SYSTEM WILL START THE GENERATOR WHEN UTILITY POWER IS RESTORED AUTO LETS THE ENGINE STABILIZE INTERNAL TEMPERATURES SHUTS OFF THE G...

Page 17: ...ercise Cycle was also set at the factory The default exercise cycle occurs on Tuesdays at 2 00 P M Central Standard Time To update or change these settings follow the steps below SET DATE If set to OF...

Page 18: ...MENU button The following will scroll across the digital display and then move to the next item Run time Date Time Exercise Cycle date and start time The user can press the LEFT ARROW or RIGHT ARROW a...

Page 19: ...ops below about 70 percent of the nominal supply voltage the sensor energizes a 3 second timer The timer is used to sense brown outs Once the timer has expired the engine will crank and start Utility...

Page 20: ...to the SET EXERCISE prompt and hit the OK button NOTICE Items will flash until they are selected SELECT DAY Use the left or right arrow to toggle through the days of the week Once the day is selected...

Page 21: ...enerator to service by pressing and holding the control board AUTO button and installing the 15 Amp fuse if removed Low Battery Voltage This service code is indicated by Low Battery Voltage scrolling...

Page 22: ...aller or an authorized dealer Engine Overspeed This service code is indicated by Engine Overspeed scrolling across the digital display To resolve the problem contact your installer or an authorized de...

Page 23: ...t be exposed to excessive dust dirt moisture or any corrosive vapors Cooling air louvers on the enclosure must not become clogged with snow leaves or any other foreign material To prevent generator da...

Page 24: ...DO NOT exceed 13 7 volts when charging NOTICE DO NOT use a battery booster to quick charge a low battery 5 Connect negative battery cable to negative battery terminal indicated by NEGATIVE NEG or 6 E...

Page 25: ...AE 30 will result in hard starting Above 80 F 27 C the use of 10W30 may cause increased oil consumption Check oil level more frequently Checking Adding Engine Oil 1 Open roof to access dipstick and oi...

Page 26: ...re installing a new oil filter lightly lubricate the oil filter gasket with fresh clean oil 9 Install the oil filter by hand until the gasket contacts the oil filter adapter then tighten the oil filte...

Page 27: ...tion and potential damage from dirt leaves rodents spider webs insects etc and remove Service Spark Plugs Changing the spark plugs will help your engine to start easier and run better 1 Clean area aro...

Page 28: ...fuel valve s check propane tank 3 Replace battery 4 Clean or replace air filter Engine shuts down during operation 1 Fuel supply turned off or depleted 2 Control board digital display shows a service...

Page 29: ...s repaired or replaced under this warranty the new part will be warranted only for the remaining warranty period If a warrantable component scheduled for maintenance fails prior to its first scheduled...

Page 30: ...emailing or writing to salesenquires briggsandstratton com au Briggs Stratton Australia Pty Ltd 1 Moorebank Avenue NSW Australia 2170 BRIGGS STRATTON POWER PRODUCTS GROUP LLC STANDBY GENERATOR OWNER...

Page 31: ...ersely affect its performance and reliability 3 Enclosure is not warranted for surface rust or corrosion or complete rust through that may result due to improper installation damage to painted surface...

Page 32: ...N o t f o r R e p r o d u c t i o n 32 This page intentionally left blank...

Page 33: ...d AC Voltage 120 240 Volts Phase Single phase Rated Frequency 60 Hertz Generator Breaker 35 Amp Normal Operating Range 20 F 28 8 C to 104 F 40 C Output Sound Level 76 8 dB A at 23 ft 7 m at normal loa...

Page 34: ...N o t f o r R e p r o d u c t i o n 34 316793 Rev A...

Reviews: