background image

10

BRIGGSandSTRATTON.COM

Features and Controls

Read this Operator’s Manual and safety rules before operating your generator.

Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.

A - Fuel Tank 

— Capacity of seven (7) U.S. gallons (26.5 L).

B - 120 Volt AC, 20 Amp, Duplex Receptacles 

— May be

used to supply electrical power for the operation of
120 Volt AC, 20 Amp, single phase, 60 Hz electrical,
lighting, appliance, tool, and motor loads.

C - Circuit Breakers (AC)

— Push-to-reset circuit breakers

are provided to protect generator against electrical
overload.

D - 120/240 Volt AC, 30 Amp Locking Receptacle

— May

be used to supply electrical power for the operation of
120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz
electrical, lighting, appliance, tool and motor loads.

E - Grounding Fastener 

— Consult your local agency having

jurisdiction for grounding requirements in your area.

F - Data Tag 

— Provides model, revision, and serial number

of generator. Please have these readily available when
calling for assistance.

G - Spark Arrester Muffler 

— Exhaust muffler lowers engine

noise and is equipped with a spark arrester screen.

H - Air Cleaner 

— Protects engine by filtering dust and

debris out of intake air.

J - Choke Lever 

— Used when starting a cold engine.

Items Not Shown:

Battery Float Charger Jack

— Use battery float charger to

keep the starting battery charged and ready for use.

Engine Identification

— Provides model, type and code of

engine. Please have these readily available if calling for
assistance.

Engine Rocker Switch 

— Set this switch to “

On

” before

using recoil starter. Set switch to “

Off

” to stop engine.

Fuel Valve

— Used to turn fuel supply on and off to engine.

Oil Drain Plug 

— Drain engine oil here.

Oil Fill Cap

— Check and fill engine with oil here.

Recoil Starter 

— Used to start the engine.

Start Button

— Push and hold in start position for a

maximum of 15 seconds during each start attempt, until
engine starts.

A

B

C

G

J

D

H

E

F

Summary of Contents for 030242-0

Page 1: ...Printed in U S A Manual No 197523GS Revision D 06 05 2007 6200 Watt Portable Generator Operator s Manual BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A ...

Page 2: ...tor is designed and intended only for supplying electrical power for operating compatible electrical lighting appliances tools and motor loads and is not intended for any other purpose It is important that you read and understand these instructions thoroughly before attempting to start or operate this equipment Save these instructions for future reference This generator requires final assembly bef...

Page 3: ...d Controls 10 Cord Sets and Receptacles 11 Battery Float Charger 12 Operation 13 Starting the Engine 13 Connecting Electrical Loads 14 Stopping the Engine 14 Don t Overload Generator 15 Maintenance 16 Maintenance Schedule 16 Generator Maintenance 16 Battery Maintenance 17 Engine Maintenance 17 Storage 20 Troubleshooting 21 Warranties 22 Emissions Control System Warranty 22 Generator Owner Warranty...

Page 4: ... moderate injury NOTICE indicates a situation that could result in equipment damage Follow safety messages to avoid or reduce the risk of injury or death The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all inclusive If you use a procedure work method or oper...

Page 5: ... stop engine with electrical devices plugged in and turned on WARNING Fuel and its vapors are extremely flammable and explosive Fire or explosion can cause severe burns or death WHEN ADDING OR DRAINING FUEL Turn generator OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fill or drain fuel tank outdoors DO NOT overfill tank Allow space fo...

Page 6: ...wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester DO NOT check for spark with spark plug removed CAUTION Excessively high operating speeds increase risk of injury and damage to generator Excessively low speeds impose a heavy load DO NOT tamper with governed speed Generator supplies correct rated frequency and voltage when running at governed speed...

Page 7: ... 7 16 and 13 mm wrenches Socket wrench with 7 16 and 13 mm sockets Pliers Safety glasses Install the wheel kit as follows 1 Tip generator so that engine end is up 2 Slide axle A through both mounting brackets 3 Place a wheel B on each side as shown below 4 Place a washer C on axle and then place an e ring D in axle groove 5 Install e ring with pliers squeezing from top of e ring to bottom of axle ...

Page 8: ...authorized dealer for high altitude adjustment information Operation of the engine at altitudes below 2 500 feet 762 meters with the high altitude kit is not recommended Attach Negative Battery Cable Your unit is equipped with electric start capability but can be started manually If you choose not to use the electric start feature you do not need to connect the negative battery cable The sealed ba...

Page 9: ...t Place generator outdoors in an area that will not accumulate deadly exhaust gas DO NOT place generator where exhaust gas A could accumulate and enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes or other openings that can allow exhaust gas to collect in a confined area Prevailing winds and air currents should b...

Page 10: ...y having jurisdiction for grounding requirements in your area F Data Tag Provides model revision and serial number of generator Please have these readily available when calling for assistance G Spark Arrester Muffler Exhaust muffler lowers engine noise and is equipped with a spark arrester screen H Air Cleaner Protects engine by filtering dust and debris out of intake air J Choke Lever Used when s...

Page 11: ...quiring up to 6 200 watts of power 6 2 kW at 25 8 Amps for 240 Volts or two independent 120 Volt loads at 25 8 Amps each The outlet is protected by a push to reset circuit breaker 120 Volt AC 20 Amp Duplex Receptacles Both duplex receptacles are protected against overload by a push to reset circuit breaker Use each receptacle to operate 120 Volt AC single phase 60 Hz electrical loads requiring up ...

Page 12: ...rt switch Plug battery charger into a 120 Volt AC wall receptacle 2 Unplug charger from unit and wall outlet when generator is being started and while it is in operation 3 Keep this charger plugged in when generator is not in use to prolong battery life The charger has a built in float equalizer and will not overcharge the battery even when plugged in for an extended period of time IMPORTANT See B...

Page 13: ...lever to Half choke position until engine runs smoothly and then to Run position IMPORTANT If engine floods place choke lever in Run position and crank until engine starts NOTE If engine starts after 3 pulls but fails to run or if unit shuts down during operation make sure unit is on a level surface and check for proper oil level in crankcase This unit may be equipped with a low oil protection dev...

Page 14: ... ON 2 Let engine run at no load for several minutes to stabilize internal temperatures of engine and generator 3 Push engine rocker switch to Off position 4 Move fuel valve to Off position 14 BRIGGSandSTRATTON COM WARNING Backfire fire or engine damage could occur DO NOT stop engine by moving choke control to Choke position NOTICE Exceeding generators wattage amperage capacity can damage generator...

Page 15: ... to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load NEVER add more loads than the generator capacity Take special care to consider surge loads in generator capacity as described above Wattages listed are approximate only Check tool or appliance for actu...

Page 16: ...arranty Generator Maintenance Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture or any corrosive vapors Cooling air slots in the generator must not become clogged with snow leaves or any other foreign material NOTE DO NOT use water or other liquids to clean generator Li...

Page 17: ... is at the point of overflowing at oil fill opening 4 Replace and tighten oil fill cap Adding Engine Oil 1 Make sure generator is on a level surface 2 Check oil level as described in Checking Oil Level 3 If needed slowly pour oil into oil fill opening to the point of overflowing at oil fill 4 Replace and tighten oil fill cap Changing Engine Oil Change the oil after the first 5 hours of operation C...

Page 18: ...de gap with wire feeler gauge and reset spark plug gap to recommended gap if necessary see Specifications 4 Replace spark plug if electrodes are pitted burned or porcelain is cracked Use the recommended replacement spark plug See Specifications 5 Install spark plug and tighten firmly Service Spark Arrester The engine exhaust muffler has a spark arrester screen Inspect and clean the screen every 10...

Page 19: ...from debris See Clean Debris Check Valve Clearance Regular valve clearance check and adjustment will improve performance and extend engine life This procedure cannot be done without partial engine disassembly and the use of special tools For this reason we recommend that you have an authorized service dealer check and adjust valve clearance at recommended intervals see Maintenance Schedule in the ...

Page 20: ...l with recommended grade See Changing Engine Oil Oil Cylinder Bore Remove spark plug and pour about 1 2 ounce 15 ml of clean engine oil into the cylinder Install spark plug and pull starter handle slowly to distribute oil Other Storage Tips 1 DO NOT store fuel from one season to another unless it has been treated as described in Long Term Storage Instructions 2 Replace fuel container if it starts ...

Page 21: ... 2 Fuel Valve is in Off position 3 Dirty air cleaner 4 Out of fuel 5 Stale fuel 6 Spark plug wire not connected to spark plug 7 Bad spark plug 8 Water in fuel 9 Flooded 10 Excessively rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Set switch to On 2 Turn fuel valve to Open position 3 Clean or replace air cleaner 4 Fill fuel tank 5 Drain fuel tank and carbur...

Page 22: ...listed in your Operating and Maintenance Instructions B S recommends that you retain all your receipts covering maintenance on your small off road engine but B S cannot deny warranty solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance As the small off road engine owner you should however be aware that B S may deny you warranty coverage if your...

Page 23: ...e or repairs The owner is responsible for the performance of all required maintenance as defined in the B S Operator s Manual 6 Consequential Coverage Coverage hereunder shall extend to the failure of any engine components caused by the failure of any Warranted Part still under warranty Emission Information Engines that are certified to meet the California Air Resources Board CARB Tier 2 Emission ...

Page 24: ...nty repair and apologize to you for being inconvenienced Any Authorized Service Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may not be appropriate For example warranty service would not apply if equipment damage occurred because of misuse lack of routine maintenance shipping handling warehousing or improper installatio...

Page 25: ...25 ...

Page 26: ...of power equipment actual on site or net power This difference is due to a variety of factors including but not limited to accessories air cleaner exhaust charging cooling carburetor fuel pump etc application limitations ambient operating conditions temperature humidity altitude and engine to engine variability Due to manufacturing and capacity limitations Briggs Stratton may substitute an engine ...

Page 27: ...Generador Portátil de 6200 Vatios Manual del Operario BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A ...

Page 28: ...s de ser usado Consulte la sección Montaje de este manual donde encontrará instrucciones para el montaje final Siga las instrucciones al pie de la letra Dónde encontrarnos Usted no tendrá que ir muy lejos para encontrar el servicio técnico de Briggs Stratton para su generador Consulte las Páginas Amarillas Hay más de 30 000 proveedores de Briggs Stratton autorizados en todo el mundo proporcionando...

Page 29: ...Juegos de cordones y enchufes conectores 11 Cargador de flotación de la batería 12 Operando 13 Encienda el motor 13 Conexión de cargas eléctricas 14 Parada del motor 14 No sobrecargar el generador 15 Mantenimiento 16 Plan de mantenimiento 16 Mantenimiento del generador 16 Mantenimiento de la batería 17 Mantenimiento del motor 17 Almacenamiento 20 Resolución de problemas 21 Garantías 22 Garantía de...

Page 30: ... el símbolo de alerta AVISO indica una situación que podría producir daños en el equipo Siga en todo momento los mensajes de seguridad para evitar o reducir el riesgo de lesiones y de muerte El fabricante no puede anticipar todas las posibles circunstancias que podrían conllevar peligro Por lo tanto las advertencias de este manual así como las etiquetas y placas de la unidad no incluyen todo Si us...

Page 31: ...n o sirvan al generador ADVERTENCIA La combustible y sus vapores son extremadamente inflamables y explosivos El fuego o una explosión pueden causar quemaduras severas e inclusive la muerte CUANDO ANADA COMBUSTIBLE O VACÍE EL DEPÓSITO Apague el generador posición OFF y déjelo enfriar al menos por 2 minutos antes de remover la tapa de la combustible Afloje la tapa lentamente para dejar que la presió...

Page 32: ...esconecte el alambre de la bujía y colóquelo donde no pueda entrar en contacto con la bujía CUANDO PRUEBE LA BUJÍA DEL MOTOR Utilice un comprobador de bujías homologado NO comprueba la chispa sin la bujía instalada PRECAUCIÓN Las velocidades de operación en exceso aumentan los riesgos de heridas y daños al generador Las velocidades bajan en exceso imponen una carga muy pesada NO cambie ninguna vel...

Page 33: ...ridad Instale el juego de ruedas conforme a las instrucciones siguientes 1 Dele la vuelta al generador de forma que el motor quede arriba 2 Introduzca el eje A a través de los dos soportes de montaje 3 Coloque una rueda B en cada extremo cuando mostrado 4 Introduzca una arandela C por el eje y coloque una anilla en e D en la ranura del eje 5 Para ello apriete con unos alicates desde la parte super...

Page 34: ...ndimiento se reducirá y el consumo de combustible y las emisiones aumentarán Para obtener más información sobre el ajuste para gran altitud consulte con un distribuidor cualificado de Briggs Stratton No se recomienda utilizar el motor a altitudes inferiores a 762 metros 2 500 pies con el juego de gran altitud Conecte el cable negativo de la batería El arranque del generador se puede realizar manua...

Page 35: ...del generador Coloque la generador a la intemperie en una zona en donde no se acumulen gases de escape mortales NO instale el generador en lugares en los que los gases de escape A se puedan acumular o entrar en un edificio que pueda estar ocupado Asegúrese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilación u otras aberturas en un espacio cerrado en el que...

Page 36: ...or y está equipado con una pantalla apagachispas H Depurador de Aire Filtra el aire de entrada a medida que penetra en el motor J Palanca Estranguladora Usada cuando se está dando arranque a un motor frío No mostrado Cargador de Flotación de la Batería Utilice el enchufe hembra del cargador de flotación de la batería para mantener la batería de arranque cargada y preparada para el uso Culatazo el ...

Page 37: ...de 60 Hz fase sencilla que requieren hasta 3 100 vatios de energía a 25 8 Amperios para 120 Voltios 6 200 vatios de energía 6 2 kW a 25 8 Amperios para 240 Voltios La salida está protegida por un corto circuito de del tipo empuje para reposicionar Tomas eléctricas dobles de 120 V CA y 20 A Cada receptáculo está protegida por un corto circuito de del tipo empuje para reposicionar Use cada receptácu...

Page 38: ...rruptor de arranque Enchufe el cargador de la batería a una toma de pared de 120 V CA 2 Desconecte el cargador de la unidad y del enchufe de la pared durante el arranque del generador y mientras esté funcionando 3 Mantenga el cargador enchufado cuando el generador no se esté utilizando para prolongar la vida de la batería El cargador incorpora un ecualizador de flotación que impide la sobrecarga d...

Page 39: ...de 5 hasta 7 7 Coloque la palanca de retroceso en la posición de Run Si el motor vacila mueva la palanca de retroceso hasta la posición media Half hasta que el motor marche suavemente y luego colóquelo en la posición de marcha Run IMPORTANTE Si el motor se desborda coloque la palanca estranguladora en la posición Run e intente arrancarlo hasta conseguirlo ADVERTENCIA El retroceso repliegue rápido ...

Page 40: ...Desconecte todas las cargas eléctricas de los tomacorrientes del panel del generador NUNCA de arranque o detenga el motor con todos los dispositivos eléctricos conectados y encendidos 2 Deje que el motor funcione sin cargas por algunos minutos para estabilizar las temperaturas internas del motor y el generador 3 Sitúe el interruptor balancín en la posición Off 4 Gire la válvula de combustible blan...

Page 41: ...mente 4 Conecte y encienda la próxima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que usted tenga NUNCA añada cargas que sobrepasen la capacidad del generador Tenga especial cuidado en contar con las cargas adicionales en la capacidad del generador como se describe arriba La potencia que aparece en la lista es aproximada Compruebe la h...

Page 42: ...ocar pérdidas de rendimiento o fallos Asimismo si penetran líquidos en el generador a través de las ranuras del aire de refrigeración parte del líquido puede permanecer en los huecos y rendijas del aislamiento del devanado del rotor y del estator El líquido y la acumulación de suciedad en los devanados internos del generador pueden reducir la resistencia del aislamiento Limpieza Limpie a diario o ...

Page 43: ... CF ENERGY CONSERVING o superior es un aceite aceptable a todas las temperaturas El uso de aceite sintético no altera los intervalos de cambio de aceite indicados Comprobación del nivel de aceite Compruebe el nivel de aceite antes de cada uso o cada 5 horas de funcionamiento como mínimo Rellene si es necesario 1 Coloque el generador sobre una superficie nivelada 2 Quite el tapón de llenado de acei...

Page 44: ...e los residuos de aceite Servicio del depurador de aire Si se utiliza con un filtro de aire sucio el motor no funcionará correctamente y puede sufrir daños Cambie el filtro de aire cada 25 horas de funcionamiento o una vez al año lo que suceda antes Haga cambios más frecuentes si trabaja en zonas sucias o donde hay polvo Para dar servicio al filtro de aire siga los pasos que se detallan a continua...

Page 45: ...mejorará y tendrá una mayor vida útil Este procedimiento no puede llevarse a cabo sin desmontar parcialmente el motor y sin usar herramientas especiales Por esta razón le recomendamos que un distribuidor autorizado compruebe y ajuste la holgura de la válvula siguiendo los intervalos recomendados consulte la sección Plan de Mantenimiento en la sección Mantenimiento Ajuste del carburador El carburad...

Page 46: ... recomendado Aceite el diámetro interior del cilindro Quite la bujía y vierta aproximadamente 15 ml 1 2 onza de aceite de motor limpio en el interior del cilindro Coloque la bujía y arranque lentamente para distribuir el aceite Otras sugerencias para el almacenamiento 1 NO guarde combustible de una temporada a otra a menos que lo haya tratado como se indica en la sección Almacenamiento Para Period...

Page 47: ...ucio 4 Sin gasolina 5 Gasolina vieja 6 El cable de la bujía no está en malas la bujía 7 Bujía defectuosa 8 Agua en la gasolina 9 Sobrecebado 10 Mezcla de combustible excesivamente rica 11 La válvula de entrada está atascada está cerrada 12 El motor ha perdido compresión 1 Gire la válvula del combustible a la posición On 2 Coloque del interruptor balancín en On 3 Limpie o reemplace el depurador de ...

Page 48: ...orrecta realización de las operaciones de mantenimiento que se enumeran en las Instrucciones de uso y mantenimiento B S recomienda conservar todas las facturas relativas al mantenimiento del motor pero B S no puede denegar la garantía basándose únicamente en la falta de facturas o en la imposibilidad por parte del propietario de asegurar la correcta realización de todas las operaciones de mantenim...

Page 49: ...urabilidad equivalentes El propietario es responsable del cumplimiento de todas las operaciones de mantenimiento obligatorio que se definen en el manual del operario de B S 6 Cobertura de daños derivados La cobertura se ampliará a los fallos de cualquier componente del motor derivados del fallo de cualquier pieza garantizada y cubierta por la garantía Información sobre emisiones Los motores con ce...

Page 50: ...os equipos sanitarios destinados al mantenimiento de las constantes vitales Esta garantía excluye los fallos debidos a hechos fortuitos y a otros acontecimientos de fuerza mayor que escapan al control del fabricante 198189S Rev B 12 31 2006 BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WI EE UU Segundo año despide sólo POLÍTICA DE GARANTÍA PARA EL PROPIETARIO DE GENERADOR PORTÁTIL BRIGGS STRA...

Page 51: ...25 ...

Page 52: ... equipos potencia en la aplicación o neta real Esta diferencia se debe entre otros a los siguientes factores accesorios filtro de aire escape carga refrigeración carburador bomba de combustible etc limitaciones de la aplicación condiciones ambientales de uso temperatura humedad altitud y variaciones entre distintos motores de un mismo modelo Briggs Stratton podrá sustituir el motor de esta serie p...

Reviews: