background image

10

11

 Clearance Dimensions

 Clearance Dimensions

 PROXIMITY TO SIDE CABINET 

INSTALLATION 

•  The cooktop may be installed directly to  
  existing base cabinets. 
• The cooktop 

CANNOT

 be installed    

  directly adjacent to sidewalls, tall cabinets, 
  tall appliances, or other side vertical 
  surfaces above 36” (91.4 cm) high. There  
  must be a minimum of 6” (15.2 cm) side 
  clearance from the cooktop to such 
  combustible surfaces above the 36” 
  (91.4 cm) counter height.
•  Within the 6” (15.2 cm) side clearance to  
  combustible vertical surfaces above 
  36” (91.4 cm), the maximum wall cabinet 
  depth must be 13” (33.0 cm) and wall 
  cabinets within this 6” (15.2 cm) side   
  clearance must be 18” (45.7 cm) above 
  the 36” (91.4 cm) high countertop. 
•  Wall cabinet above the cooktop must be 
  a minimum of 36” (91.4 cm) above the 
  countertop for a full width of the cooktop.
•  If a ventilation hood is installed over the 
  cooktop, the minimum 36” (91.4 cm) 
  height clearance above the unit does not 
  apply. Refer to the hood installation 
  instructions for further information. 

 INTERIOR CABINET CLEARANCES 

INDUCTION COOKTOPS 

 

IMPORTANT:

 The electronic components 

for the induction elements in the cooktop 
need air circulation. To ensure long life of 
electronic components, it is required that 
1-1/2 (3.8 cm) or more open space remains 
between the bottom of the cooktop and any 
shelf underneath. The maximum length of 
the shelf underneath is 18” (45.7 cm). It is 
required that the exit air ports at the front are 
not blocked.

 WOOD/COMPOSITE OVERLAY

 The bottom of a standard hood should be 
30” (76.2 cm) min. to 36” (91.4 cm) max. 
above the countertop. This would typically 
result in the bottom of the hood being 
66” (167.6 cm) to 72” (182.9 cm) above the 
fl oor. Refer to the rangehood installation 
instructions for additional information. These 
dimensions provide for safe and effi cient 
operation of the hood.

36” min.

 

(91.4 cm)*

13” max.

 

(

33.0 cm)

6” min.

(15.2 cm)**

18” min.

(45.7 cm)

3-1/8”

 

(7.9 cm)

1” min.

 

(2.5 cm)

36” min. 

(91.4 cm)

18”

(45.7 cm) max.

1-1/2”

(3.8 cm) min.

Hot Air

Hot Air

Hot Air

Good Design

Optimum Design

Bad Design

Cool Air

Cool Air

Cool Air

Minimum Clearances from Adjacent 
Combustible Construction 

•  Above countertop 36” (91.4 cm) minimum 
•  Side 6” (15.2 cm)
•  Rear 0” (0.0 cm) 
•  Within 6” side clearance. Wall cabinets no  
  deeper than 13” (33.0 cm) 
•  Must be minimum 18” (45.7 cm) above  
 countertop 
•  Wall cabinets directly above the product  
  must be minimum 36” (91.4 cm) above the  
 countertop

For Brazil/Mexico Only: 

It is 

recommended that a removable shelf be 
installed under the appliance after it has 
been fully installed to prevent
unintended access to the appliance 
during use. 

Note:

 Dimensions shown are for use 

with combustible surfaces unless 
otherwise stated.

66”min.

(167.6 cm)

to

72”max.

(182.9 cm)

66”min.

(167.6 cm)

to

72”max.

(182.9 cm)

24”

(61.0 cm)

30”

(76.2 cm)

6”

(15.2 cm)

Wood/Composite 

Overlay

Wood/Composite 

Overlay

30”min.

(76.2 cm)

to

36”max.

(91.4 cm)

30”min.

(76.2 cm)

to

36”max.

(91.4 cm)

Summary of Contents for CVEC5304BSB

Page 1: ...Built In Electric Cooktops Built In Induction Cooktops Viking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit the Viking W...

Page 2: ..._14 Performance Checklist___________________________________________14 Service Registration ___________________________________________15 Your safety and the safety of others is very important We have...

Page 3: ...78 1 cm 36 3 4 93 3 cm Overall height from bottom To top of knobs To top of cooking surface To bottom edge of frame 4 3 4 12 1 cm 3 1 2 8 9 cm 2 5 8 6 7 cm Overall depth from rear 21 53 3 cm Cutout w...

Page 4: ...cm maximum 34 3 4 88 3 cm minimum to 35 3 4 90 8 cm maximum Cutout depth 19 3 16 48 7 cm minimum to 20 50 8 cm maximum Electrical requirements 240 208 120 VAC 50 60Hz factory installed 4 ft 121 9 cm f...

Page 5: ...28 3 4 73 0 cm 20 1 4 51 4 cm 2 1 4 2 2 cm 7 8 2 2 cm 27 68 6 cm 20 1 4 2 1 4 7 8 7 8 34 3 4 88 3 cm 51 4 cm 5 7 cm 2 2 cm 2 2 cm 33 83 8 cm 36 W CUTOUT w DOWNDRAFT 36 min 91 4 cm 28 1 8 71 4 cm 5 12...

Page 6: ...ngth of the shelf underneath is 18 45 7 cm It is required that the exit air ports at the front are not blocked WOOD COMPOSITE OVERLAY The bottom of a standard hood should be 30 76 2 cm min to 36 91 4...

Page 7: ...t connect the bare ground connector lead of the unit to the branch circuit ground bare wire or green in color WARNING The electrical power to the unit must be shut off while line connections are being...

Page 8: ..._____________________________________________________________________ Address ______________________________________________________________________________ These installation instructions should rema...