10
11
Clearance Dimensions
Clearance Dimensions
PROXIMITY TO SIDE CABINET
INSTALLATION
• The cooktop may be installed directly to
existing base cabinets.
• The cooktop
CANNOT
be installed
directly adjacent to sidewalls, tall cabinets,
tall appliances, or other side vertical
surfaces above 36” (91.4 cm) high. There
must be a minimum of 6” (15.2 cm) side
clearance from the cooktop to such
combustible surfaces above the 36”
(91.4 cm) counter height.
• Within the 6” (15.2 cm) side clearance to
combustible vertical surfaces above
36” (91.4 cm), the maximum wall cabinet
depth must be 13” (33.0 cm) and wall
cabinets within this 6” (15.2 cm) side
clearance must be 18” (45.7 cm) above
the 36” (91.4 cm) high countertop.
• Wall cabinet above the cooktop must be
a minimum of 36” (91.4 cm) above the
countertop for a full width of the cooktop.
• If a ventilation hood is installed over the
cooktop, the minimum 36” (91.4 cm)
height clearance above the unit does not
apply. Refer to the hood installation
instructions for further information.
INTERIOR CABINET CLEARANCES
INDUCTION COOKTOPS
IMPORTANT:
The electronic components
for the induction elements in the cooktop
need air circulation. To ensure long life of
electronic components, it is required that
1-1/2 (3.8 cm) or more open space remains
between the bottom of the cooktop and any
shelf underneath. The maximum length of
the shelf underneath is 18” (45.7 cm). It is
required that the exit air ports at the front are
not blocked.
WOOD/COMPOSITE OVERLAY
The bottom of a standard hood should be
30” (76.2 cm) min. to 36” (91.4 cm) max.
above the countertop. This would typically
result in the bottom of the hood being
66” (167.6 cm) to 72” (182.9 cm) above the
fl oor. Refer to the rangehood installation
instructions for additional information. These
dimensions provide for safe and effi cient
operation of the hood.
36” min.
(91.4 cm)*
13” max.
(
33.0 cm)
6” min.
(15.2 cm)**
18” min.
(45.7 cm)
3-1/8”
(7.9 cm)
1” min.
(2.5 cm)
36” min.
(91.4 cm)
18”
(45.7 cm) max.
1-1/2”
(3.8 cm) min.
Hot Air
Hot Air
Hot Air
Good Design
Optimum Design
Bad Design
Cool Air
Cool Air
Cool Air
Minimum Clearances from Adjacent
Combustible Construction
• Above countertop 36” (91.4 cm) minimum
• Side 6” (15.2 cm)
• Rear 0” (0.0 cm)
• Within 6” side clearance. Wall cabinets no
deeper than 13” (33.0 cm)
• Must be minimum 18” (45.7 cm) above
countertop
• Wall cabinets directly above the product
must be minimum 36” (91.4 cm) above the
countertop
For Brazil/Mexico Only:
It is
recommended that a removable shelf be
installed under the appliance after it has
been fully installed to prevent
unintended access to the appliance
during use.
Note:
Dimensions shown are for use
with combustible surfaces unless
otherwise stated.
66”min.
(167.6 cm)
to
72”max.
(182.9 cm)
66”min.
(167.6 cm)
to
72”max.
(182.9 cm)
24”
(61.0 cm)
30”
(76.2 cm)
6”
(15.2 cm)
Wood/Composite
Overlay
Wood/Composite
Overlay
30”min.
(76.2 cm)
to
36”max.
(91.4 cm)
30”min.
(76.2 cm)
to
36”max.
(91.4 cm)