briechle elektronik ABW 24-12-6H Installation Manual Download Page 2

If 2

sockets
installed

Socket

24V

Flasher left yellow L

Flasher right green R

Stop light red 54

Rear lamp left black 58L

Rear lamp right brown 58R

Rear fog lamp blue (54g)

ABW 24-12-6H

Lead ground

through or from

one side to the

converter

Socket

12V

Ground
white 31

Cable loom

Connection in
cable case or
in parallel to
the rear lights

54 58L

R

58R

L

54g

31

54 58L

R

58R

L

54g

31

Technical data:

Maximum load: flasher 2x21W,
other lines 60W each
Efficiency: flasher ab. 90%,
other lines ab. 95%
Dimensions: 200 x 70 x 25mm
without cable outlet
Mounting hole distance: 185mm,
Weight: 960g

Level 11/13

Installation manual

trailer light converter ABW 24-12-6H

Requirements:

1. The converter is only suitable for the operation of incandescent bulbs and RMS-LEDs *1).
2. The installing locality mustn’t be exposed to splash water (de-icing salt risk).
3. The installing locality must show air circulation (no wrapping in insulating material!).
4. All connections have to be made very carefully. Insulated crimp connections have to be pressed

together adequately, insulation displacement connectors have to be used according to cable size.

Installation:

1. All wires must be dead before tapping.
2. Fixing of the converter with delivered M4-screws.
3. First of all make connection to ground (31), then connection of the seven lines in parallel to the

loom of cables of the trailer. The cables have to be connected as follows. Input and output are of
the same colour.

Rear lamp left and rear lamp right may never be connected!

Funktion

Function

code

Farbe/colour

Masse

Ground

31

weiß/white

Blinker links

Flasher left

L

gelb/yellow

Blinker rechts

Flasher right

R

grün/green

Schlussleuchte links Rear lamp left

58L

schwarz/black

Schlussleuchte rechts Rear lamp right

58R

braun/brown

Bremsleuchte

Stop light

54

rot/red

Nebelschlussleuchte Rear fog lamp

54g

blau/blue

4.

Socket test lamp for functional testing.

Special case:

For the replacement of a damaged original converter in a DB UNIMOG also the second converter must be
removed. Please ask for replacement instruction.

Disturbances:

The short circuit protecting device prevents the blowing of series fuses. When the short circuit is eliminated, the
converter automatically resets itself after disconnection of the input. In case of overheating (e.g. accumulation of
heat caused by covering) the converter could heat itself to a point where the power of the bulbs is taken down. After
cooling, full power is available again. So the converter doesn’t get out of order.
Voltage measuring with normal multimeters is only conditionally possible.
Because of the special converter principle (RMS-power converter), such a meter only indicates about a quarter of
the input voltage at all lines (basic load 5W) except the flashing units where the voltage is indicated nearly exactly
(basic load 21W). For details, please see testing instruction.

Notes:

*1)

RMS-LEDs are working with internal series resistors or other suitable techniques. If reduction of light intensity occurs in

RMS pulse operation the reduction must remain within the light intensity limits of the ECE regulations (R6, R7, R23, R38).
If series resistor technology is used, light intensity reduction of 20% to 35% must be expected. The nominal light intensity of the
LED lamp unit for 12V operation is mentioned in the manufacturer’s ECE approval.

Caution! ISO –Colours

For measuring a basic load of 5W/21W is required!