background image

 

 

 

 

 

 

 

 

 

 

 

P/N 580-00516 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BW64E 

Installation Guide 

 

045-57013  Rev B 

 

 

 

 

 

 

 

 

 

 

 

 

BW64E 

Summary of Contents for BW64E

Page 1: ...P N 580 00516 BW64E Installation Guide 045 57013 Rev B BW64E...

Page 2: ...e limited to those commitments to the purchaser set forth in its Standard Terms and Conditions of Sale for a delivered product This publication has been prepared for professional and properly trained...

Page 3: ...ile it is operating The outdoor equipment must be properly grounded to provide some protection against voltage surges and built up static charges In the event of a short circuit grounding reduces the...

Page 4: ...and 2 This device must accept any interference that may cause undesired operation French Translation Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempt...

Page 5: ...requency RF electromagnetic fields the BW64E has been evaluated for compliance with FCC OET Bulletin 65 and human exposure limits recommended by the International Commission on Non Ionizing Radiation...

Page 6: ...4 2 5 Antenna Location 5 2 6 Cabling Power Requirements 5 2 7 Example Cabling Diagrams 8 2 8 Grounding Lightning 10 2 9 Conduit 10 3 Installation 11 3 1 Overview 11 3 2 Equipment Unpacking 11 3 3 Equi...

Page 7: ...WARNING and NOTE statements have been placed in various sections throughout this document to alert personnel of possible traffic affecting issues and to provide additional tips and helpful informatio...

Page 8: ...APAC Asia Pacific UTC 8 1 408 457 6659 The UTC coverage times do not reflect daylight saving time adjustments E mail support bridgewave com Return Material Authorization RMA Should BridgeWave equipmen...

Page 9: ...d other long term incremental obstructions such as trees Intermittent obstructions such as aircraft at a nearby airport should also be considered The following table details the minimum clearance need...

Page 10: ...standoff Location where the cabling will enter exit the building Length of cable runs Grounding connection points Potential path obstructions Accessibility There is a finite incline and decline range...

Page 11: ...Type Part Cable Type Length 171 00511 1000Base SX GigE multi mode 850nm LC Connector 62 5 125 m MMF 270m 50 125 m MMF 500m 171 00512 1000Base LX GigE single mode 1310nm LC Connector 9 125 m SMF 10km...

Page 12: ...to 60VDC 45W Max Power Dissipation Recommend Min 60W Power Source 12 AWG Stranded 4mm2 or 14 AWG Stranded 2 5mm2 Figure 2 2 Cable Power Specification With POE64 Kit Option 1 GigE SFP Part Type Part C...

Page 13: ...Surge port of POE64 Extractor Power Requirements Cable Type Length 56 VDC 45W Max Power Dissipation Recommend Min 60W PoE Power Source Cat5E or Cat6 100m 2 7 Example Cabling Diagrams Error Not a valid...

Page 14: ...rt 020 57069 0001 3rd party parts not supplied by BridgeWave Optional accessories sold by BridgeWave Conduit Ethernet Surge Arrestor Optional for Out of Band Management DC Surge Arrestor Copper or Fib...

Page 15: ...d by BridgeWave Conduit Ethernet Surge Arrestor Optional for Out of Band Management Ethernet Surge Arrestor GigE SFP Rx Tx Power 48V Test 10 100BaseT Link Act PoE Radio Link Up Connections Inside Unit...

Page 16: ...e use of surge suppressors The surge suppressor must be installed at the point where the cables exit enter the building however use of a surge suppressors at the radio unit are optional because surge...

Page 17: ...Check the site plans to determine which band will be installed at each location and then locate the desired box low band or high band accordingly before beginning installation It is recommended that t...

Page 18: ...NATION WRENCH 1047 651 00507 1 TOOL 9 16 INCH COMBINATION WRENCH 1047 370 00608 1 WASHER 8 FLAT SS 1047 370 00613 1 SCR 8 32 UNC X 3 8 PHIL PAN SS Additionally the following accessories are available...

Page 19: ...nstalling the radio Screwdriver slotted 0 1 inch 2 5mm wide Ratchet with 6 inch 15cm extension and 9 16 inch 14 29mm deep socket Ratchet with 6 inch 15cm extension and 1 2 inch 12 7mm deep socket Wire...

Page 20: ...ket Attach Antenna to Mounting Plate Attach Antenna to Mast a Ensure plugs are removed from bottom two drain holes b Reinstall the plugs at the top of the antenna Rotate Mounting Plate 180 for Left Ha...

Page 21: ...h the radio unit to the back of the antenna by securing the 4 3 8 16 bolts a Locate polarity sticker b Orient unit so that line is left to right for horizontal or up and down for vertical Unit Oriente...

Page 22: ...radio on one side of the link set in the horizontal polarization and the other side of the link set in the vertical polarization will not operate properly It is also critically important that a high b...

Page 23: ...Bracket Qty 1 CAT5E Jumper Qty 1 4 40x1 4 Screw Washer Qty 3 1 2 Remove protective cap from SFP cage Insert GiGE Copper SFP into SFP cage with SFP label facing down Protective Cap SFP Inserted SFP Lab...

Page 24: ...ble from external PoE power source through the conduit and fitting into the unit and attach to the port labeled Power Data Input on the Poe Extractor Port labeled Power Data Input Cat5e Cat6 Cable 100...

Page 25: ...o a ground source since this provides the largest grounding surface contact possible If this is not possible then use the following procedure 1 Attach the lug of a 10 AWG ground cable to the radio at...

Page 26: ...onduit provides a water tight entry to the radio as well as any weather or physical protection required by the cables The conduit should be flexible waterproof and non metallic An example of this is L...

Page 27: ...the conduit so that the tapered end of the Sealing Ring faces away from the Compression Nut 4 Next pass the cables through the Ferrule and screw the Ferrule onto the end of the conduit Depending on q...

Page 28: ...Wires to DC Connector not required when using POE64 kit 1 Ensure that the DC wire used is either 12 or 14 gauge and the center conductor is comprised of stranded wiring and ensure that a grounded sur...

Page 29: ...es or shapes the radiated energy into a specific direction As a result of this focusing a majority of the energy directed into the main beam However as a byproduct side lobes are also formed These sid...

Page 30: ...dial set the meters dial for the x20 scale For alignment only the lead labeled GND and the lead labeled RSL are needed The RSL voltage will be dependent on the link distance but will max out at just o...

Page 31: ...or free wireless link Quality Voltages between 1 5V and 3 0V indicate a low rate of errors and that the forward error correction will correct The lower the voltage the more errors are being corrected...

Page 32: ...minpass 3 Go to the Setup page and set the Alignment Mode parameter to Enabled Alignment Mode is Enabled by default For new installations steps 2 and 3 can be skipped 4 Connect the provided RSL QUAL T...

Page 33: ...side lobes and nulls Tighten the Antenna Mounting Bolts once the maximum RSL voltage is observed 10 Perform steps 8 and 9 on both ends of the link Only align one end of the link at a time 11 Once the...

Page 34: ...he Ice Shield kit contains the following parts for installation at one site Two kits are required if installing one at each end of the link 3 12 2 Installation Instructions 1 Remove the protective cov...

Page 35: ...erating range Check the output of the power supply with the DC cabling disconnected from the supply If within range then the cable run is too long or the cable gauge is too small Shorten the length of...

Page 36: ...high and the other end is a low band radio see Section 3 6 Link exceeds maximum specified range Verify that maximum path length has not been exceeded Low link quality voltage Antennas are not aligned...

Page 37: ...BW64E Installation Guide 32 045 57013 Rev B BridgeWave Confidential Proprietary...

Page 38: ...BW64E Installation Guide 33 045 57013 Rev B BridgeWave Confidential Proprietary Appendix B RSL Voltage vs Distance Figure 3 6 RSL Voltage vs Distance...

Page 39: ...occurred BridgeWave may charge its standard rates for any repair or replacement work performed on returned Product that was not in breach of the warranties herein Replacement Product Warranty The Warr...

Page 40: ...EDIES SET FORTH IN THIS LIMITED WARRANTY AND SOFTWARE LICENSE ESTABLISH THE ENTIRE OBLIGATION OF BRIDGEWAVE AND BUYER S SOLE REMEDY IN REGARD TO CLAIMS RELATING TO BREACH OF WARRANTY OR INTELLECTUAL P...