8.4.3 Let out used Oil (B17)
- Open the oil filler screw (9).
- Drain the used oil into a suitable receptacle by tilting the generator.
8.4.4 Changing Engine Oil
- changing engine oil refers to the content in 8.4.3 and 8.4.1.
8.5 Oil shortage cut-out
This generator has a Low Oil level Protection system.
The oil shortage cut-out responds if there is too little oil in the engine. In this case it will not
be possible to start the engine or it will cut out automatically after a short period of time. It
cannot be started again until the engine oil has been topped up (see point 8.4.1).
8.6 Storage
f the generator is going to stop used for long time (more than 3 months).
Make sure have done following points:
- Make sure the fuel tank is empty.
The fuel tank of the generator is not fully sealed. Long time fuel storage could cause fuel deteriorate.
- Make sure there is no fuel in the carburetor.
To empty the carburetor. Unscrew the carburetor out let screw. Collect the fuel inside. Then screw
it back on or run the generator with no load till stop.
Fuel residual could cause carburetor jamming.
- Make sure the engine is oil empty.
Emptying the oil refers to the content in 8.4.3.
Long time oil storage could cause oil deteriorate.
Deteriorated oil could jam the oil sensor.
Important!
Never storage the generator exposed out door.
9. TRANSPORT
ATTENTION!
Slipping or falling unit can crush hands and feet.
- Carry the generator on transportation handles:
- Lift the generator evenly.
- Carry the generator to the operating place.
- Drop the generator evenly.
10. TROUBLESHOOTING
Fault
Cause
Remedy
Engine does not start
Oil shortage cut-out has not
responded
Spark plug fouled
No fuel
Battery voltage too low
Check oil level, top up engine oil
Clean or replace spark plug
(electrode spacing 0.6-0.7 mm)
Refuel / check the petrol cock
Charge the battery
Generator has too little or no
voltage
Controller or capacitor
defective
Overload cut-off has triggered
Air filter dirty
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Clean or replace the filter
Summary of Contents for 5411074231583
Page 2: ......
Page 3: ......
Page 4: ......
Page 5: ......
Page 35: ...SCH MA LECTRIQUE ELEKTRISCH SCHEMA ELECTRICAL DIAGRAM...
Page 37: ...FIG 3 Couverture de silencieux Uitlaatklep Muffler Cover F61 FIG 4 F61 FIG 5 F61...
Page 38: ...FIG 6 Panneau de commande Controlepaneel Control Panel F62 fig 7 rotor stator f63 14...
Page 41: ...FIG 6 Syst me de mise feu Ontbrandingssysteem Ignition System Ass y...