background image

9

Functions

 OPERATING YOUR AIR PURIFIER

1.  Press the   POWER button to turn on and 

the On/Filter reset light will illuminate.

2.  The air quality sensor light will illuminate, 

usually starting with a blue light until it has 

time to sense the air quality and then it may 

change to an alternate colour.

3.  To adjust how the air purifier operates, follow 

the directions below.

NOTE

The filter reset light will blink continuously 

indicating that the filter needs to be replaced. 

To reset the indicator after the filter has been 

replaced, press and hold the   POWER  

button for 5 seconds and the filter reset light  

will turn off.

SensAir

TM

 LIVE PURITY CONTROL

• 

Your Breville Smart Air

TM

 Purifier has a  

built-in air quality sensor to detect changes  

to air quality in the surrounding area.

• 

The SensAir

TM

 light around the control panel 

will change colours according to the quality of 
the surrounding air. 

Microbe Shield

TM

/NIGHT MODE

The Microbe Shield

TM

 and Night Modes utilise  

the same button on the control panel. Pressing 

the   Microbe Shield

TM

/NIGHT button  

will cycle through these two settings.

Microbe Shield

TM

• 

Press the   Microbe Shield

TM

/NIGHT mode 

button until the Microbe Shield

TM

 indicator 

light illuminates to turn it on.

• 

Press again until the light extinguishes to  

turn off this function.

Night Mode

• 

To turn on Night Mode, press the   Microbe 

Shield

TM

/NIGHT button until  

the night indicator light starts to blink.

• 

After 10 blinks, all indicator lights on 

the control panel will turn off as the unit 

enters night mode and the fan speed will 

automatically change to Low.

• 

Press any button on the control panel to  

re-engage the control panel and turn off night 

mode. The indicator light will extinguish.

FAN SPEED/TURBO MODE

NOTE

The air purifier will resume in the last 

programmed setting once it has been turned 

off, even if turned off at the power outlet. If the 

last programmed setting was Night mode, once 

turned on, the control panel will illuminate with 

the Night indicator light blinking as a reminder 

that Night mode has been set.

• 

Press the   FAN SPEED button repeatedly  

until the desired speed is illuminated on the  

control panel. 

• 

There are 4 fan speeds: Low, Medium, High  

and Turbo.

• 

The purifier has reached Turbo mode when  

all three lights are illuminated on the control  

panel at the same time.

NOTE

When changing the fan speed, the unit may  

take a few seconds to adjust.

TIMER  

• 

The air purifier can be set to operate for  

timed intervals of 2 hours, 4 hours and 8  

hours, stopping automatically when the 

selected operating time has elapsed. If no  

timer is set, the air purifier will continuously 

operate until it is manually switched off.

LAP300_ANZ_IB_C19.indd   9

19/3/19   4:07 pm

Summary of Contents for LAP300

Page 1: ...the Smart AirTM Purifier Instruction Book LAP300 LAP300_ANZ_IB_C19 indd 1 19 3 19 4 07 pm ...

Page 2: ...and filter for the first time To eliminate a choking hazard for young children remove and safely discard the protective cover fitted to the power plug of this air purifier When unpacking the air purifier check to see you have received all the items listed in the parts list before discarding the packaging This air purifier is intended for household use only and not for commercial or industrial use ...

Page 3: ... run the power cord under carpeting or cover the power cord with rugs runners or the like Arrange the power cord away from traffic areas and where it will not be tripped over Do not route power cord under furniture or appliances Do not operate the air purifier with a damaged power cord or plug or if the air purifier has been dropped or damaged in any manner Take the air purifier to your nearest Br...

Page 4: ...ver the edge of a bench or table touch hot surfaces or become knotted To protect against electric shock do not immerse the power cord power plug or appliance in water or any other liquid or allow moisture to come in contact with the part unless it is recommended in the cleaning instructions The appliance is not intended for use by persons including children with reduced physical sensory or mental ...

Page 5: ...om the power source at the wall socket to prevent any electrical surges that may arise during the storm and which may inadvertently cause damage to the appliance and its electronic componentry Always turn the appliance to the off position switch off at the power outlet and unplug at the power outlet when the appliance is not in use Before cleaning always turn the appliance to the off position swit...

Page 6: ...trol Panel C Main Housing Body D Air Quality Sensor E Air Inlet F Microbe ShieldTM Light and Light Guard G 3 Layer Filter H Base Plate I Locking Knob NOT PICTURED Power Cord A B C D E G F H I LAP300_ANZ_IB_C19 indd 6 19 3 19 4 07 pm ...

Page 7: ...des 4 speed modes Low Medium High and Turbo E Air Quality Sensor Light The Breville Smart AirTM Purifier has a visible air quality sensor light around the control panel The light illuminates to indicate the quality of the surrounding air according to the table following E D B A C Grade Air Quality Colourof Light 1 Very Good Blue 2 Good Yellow 3 Fair Orange 4 Poor Red LAP300_ANZ_IB_C19 indd 7 19 3 ...

Page 8: ...wave UV C light specially designed to target germs and bacteria from the incoming air as it passes through the air purifier before releasing the air back into the surrounding area The Microbe ShieldTM function can be turned on and off according to preference Assembly Features BEFORE FIRST USE Remove and safely discard any packaging material or promotional labels attached to your air purifier and f...

Page 9: ... the light extinguishes to turn off this function Night Mode To turn on Night Mode press the Microbe ShieldTM NIGHT button until the night indicator light starts to blink After 10 blinks all indicator lights on the control panel will turn off as the unit enters night mode and the fan speed will automatically change to Low Press any button on the control panel to re engage the control panel and tur...

Page 10: ...rn Auto off and beneath Auto indicator light will extinguish IMPORTANT Turning the unit On and Off will require cycling through the Auto mode FILTER RESET The On Filter reset light will blink continuously indicating that the filter needs to be replaced Replace the filter according to the directions found under Replacing the Filter in this book Once the filter is replaced press and hold the POWER b...

Page 11: ...ind a grill at the rear of the unit Gently vacuum the air quality sensor grill using a small hand brush tool Cleaning should occur regularly at least once a month If more dust can be seen on the sensor behind the grill then remove the cover by using the raised tab on the edge of the cover Push inwards and outwards simultaneously to open the cover noting that it will be tight Gently vacuum the meta...

Page 12: ... filter The filter can be placed into the unit either way NOTE If the filter is not in place or not fitted correctly the air purifier will not operate WARNING Unintended use of the air purifier or damage to the housing may result in the escape of dangerous Microbe ShieldTM UV C radiation which is dangerous to the eyes and skin Never operate the UV C light outside of the air purifier UV C LIGHT CAR...

Page 13: ...correctly in place Insufficient air flow Check that the filters are clean Check for any obstructions in the air inlet and or outlet Excessive noise Check for any foreign objects that may be in contact with the fan Check if the filter is clogged and ready for replacement Check that the air purifier has been assembled correctly and the locking knob has been tightened Check that the unit is on a leve...

Page 14: ...14 NOTES LAP300_ANZ_IB_C19 indd 14 19 3 19 4 07 pm ...

Page 15: ...15 NOTES LAP300_ANZ_IB_C19 indd 15 19 3 19 4 07 pm ...

Page 16: ...le the Breville logo Master Every Moment Smart Air SensAir and the Microbe Shield logo are trademarks of Breville Pty Ltd A B N 98 000 092 928 Copyright Breville Pty Ltd 2019 Due to continued product improvement the products illustrated photographed in this booklet may vary slightly from the actual product LAP300 ANZ C19 LAP300_ANZ_IB_C19 indd 16 19 3 19 4 07 pm ...