background image

10

Humidity indicator 

The humidity indicator (15) displays the following conditions:

WET

Wet. Indoor humidity between 66% and 95%

COMFORT Comfortable. Indoor humidity between 45% and 65%

DRY

Dry. Indoor humidity between 20% and 40%

 NOTE!  

Read chapter "Ventilation indicator" for more information.

Temperature and humidity MAX/MIN records 

1.  Press the touch control MEM/  (10a) several times to switch between the 

values for current, minimum (MIN) and maximum (MAX) temperature and 

humidity. The display will change for the indoor temperature as well as for 

the outdoor temperature.

2.  

The MIN/MAX temperature and humidity values will be recorded 

automatically. 

 NOTE!

Depending on the selected type for measurement data storage the MIN/MAX 

values will be saved for 24 hours or until batteries need to be changed (Read 

chapter "Manual time setting and other settings").

Atmospheric change 

The device uses the measurement data to calculate the absolute humidity. 

The icons indicate how the ventilation would affect the indoor climate:

Moister. Expected increase in humidity by 5% or more.

Constant. Expected increase or decrease in humidity by a 

maximum of 4%.

Dryer. Expected decrease in humidity by 5% or more.

 NOTE!

Manual_7007401_RC-Hygrometer_en-de_BRESSER_v082019a.indd   10

26.08.2019   08:12:25

Summary of Contents for 7007401

Page 1: ...B INSTRUCTION MANUAL DE BEDIENUNGSANLEITUNG RC Hygrometer with outdoor sensor Funk Hygrometer Mit Außensensor Art No 7007401 anual_7007401_RC Hygrometer_en de_BRESSER_v082019a indd 1 26 08 2019 08 12 22 ...

Page 2: ... informazioni esaustive su questo prodotto in una lingua specifica Venga a visitare il nostro sito Web al seguente link codice QR Code per conoscere le versioni disponibili PT Deseja um manual detalhado deste produto numa determinada língua Visite a nossa Website através da seguinte ligação QR Code das versões disponíveis ES Desearía recibir unas instrucciones de uso completas sobre este producto ...

Page 3: ...3 Fig 2 D a b c Batterien nicht enthalten Batteries not included anual_7007401_RC Hygrometer_en de_BRESSER_v082019a indd 3 26 08 2019 08 12 24 ...

Page 4: ...4 2 Fig 3 Batterien nicht enthalten Batteries not included anual_7007401_RC Hygrometer_en de_BRESSER_v082019a indd 4 26 08 2019 08 12 24 ...

Page 5: ...via a power source batteries Children should only use the device under adult supervision Only use the device as described in the manual otherwise you run the risk of an electric shock RISK OF CHEMICAL BURN Leaking battery acid can lead to chemical burns Avoid contact of battery acid with skin eyes and mucous membranes In the event of contact rinse the affected region immediately with a plenty of w...

Page 6: ...batteries SCOPE OF DELIVERY Fig 1 Main unit A outdoor sensor B instruction manual PARTS OVERVIEW Main unit Fig 2 1 Outdoor temperature 2 MIN MAX value 3 Sensor channel 4 Low battery indicator outdoor sensor 5 Outdoor humidity 6 Alarm enabled 7 Time signal indicator 8 Current time or alarm time 9 Ventilation indicator Window 10 Touch controls a MEM b AL SET c CH 11 Atmospheric change indicator 12 I...

Page 7: ...s Due to external influences various RC devices and other sources of interference the maximum distance can be greatly reduced In such cases we suggest to position the main unit and the outdoor sensorat other places Sometimes all it takes is a relocation of one of these components of a few inches Though the remote unit is weather proof it should be placed away from direct sunlight rain or snow POWE...

Page 8: ...or temperature is above or below the measurement range the display will show HHH high or LLL low Automatic time setting After installing the batteries the main unit it will automatically search for the DCF time signal During this process the symbol is flashing After successful signal reception the current time 8 will be displayed and the symbol disappears If the time signal was not received press ...

Page 9: ... for approx 3 seconds to enter the alarm time settings mode Hours will flash 2 Press the MEM or CH touch control 10a 10c to set the desired hours 3 Press the AL SET to switch to the next setting 4 Press the MEM or CH touch control 10a 10c to set the desired minutes 5 Press the AL SET to switch to the next setting 6 Press the MEM or CH touch control 10a 10c to switch between ON or OFF to enable or ...

Page 10: ... as for the outdoor temperature 2 The MIN MAX temperature and humidity values will be recorded automatically NOTE Depending on the selected type for measurement data storage the MIN MAX values will be saved for 24 hours or until batteries need to be changed Read chapter Manual time setting and other settings Atmospheric change The device uses the measurement data to calculate the absolute humidity...

Page 11: ...ld be opened wide for a short time a few minutes for effective ventilation If possible open windows on opposite sides of the apartment full ventilation Even if ventilation is not recommended by the weather station due to the humidity the apartment should be ventilated regularly This contributes to the reduction of pollutants and other volatile compounds in the room air Humidity comfort level Ambie...

Page 12: ...s such as headphones or speakers operating on the same signal frequency 433 MHz 4 Electrical devices operating on the same signal frequency may also cause interference This can include devices used in the neighborhood as well Main unit channel setting 1 The main unit can be connected with a maximum of up to 3 transmitters 2 Press the touch control CH 10c to switch between the displays of each chan...

Page 13: ... sensor is still in place 2 The batteries of both the sensor and the main unit are not empty Replace batteries with new ones if necessary NOTE Resolution for temperature 0 1 Humidity range 20 95 RH Resolution for humidity 1 Transmission Transmission range between transmitter and main unit 50 meters in open area Radio frequency 433 MHz Maximum radio frequency power 10 mW Power supply Main unit 3x A...

Page 14: ...g batteries and rechargeable batteries disposing of them in the normal household waste is explicitly forbidden Please make sure to dispose of your used batteries as required by law at a local collection point or in the retail market Disposal in domestic waste violates the Battery Directive Batteries that contain toxins are marked with a sign and a chemical symbol Cd cadmium Hg mercury Pb lead EC D...

Page 15: ... period and details of our services at www bresser de warranty_terms Would you like detailed instructions for this product in a particular language Then visit our website via the link below QR code for available versions Alternatively you can also send an email to manuals bresser de Please always state your name precise address a valid phone number and email address as well as the article number a...

Page 16: ...S Dieses Gerät beinhaltet Elektronikteile die über eine Stromquelle Batterien betrieben werden Lassen Sie Kinder beim Umgang mit dem Gerät nie unbeaufsichtigt Die Nutzung darf nur wie in der Anleitung beschrieben erfolgen andernfalls besteht GEFAHR eines STROMSCHLAGS VERÄTZUNGSGEFAHR Ausgelaufene Batteriesäure kann zu Verätzungen führen Vermeiden Sie den Kontakt von Batteriesäure mit Haut Augen un...

Page 17: ...en Typen oder unterschiedlich hoher Kapazität Entfernen Sie Batterien aus dem Gerät wenn es längere Zeit nicht benutzt wird Für Spannungsschäden in Folge falsch eingelegter Batterien übernimmt der Hersteller keine Haftung LIEFERUMFANG Fig 1 Hauptgerät A Außensensor B Bedienungsanleitung TEILEÜBERSICHT Hauptgerät Fig 2 1 Außentemperatur 2 MIN MAX Wert 3 Sensor Kanal 4 Batteriestandsanzeige Außensen...

Page 18: ... in richtiger Reihenfolge wieder neu einsetzen damit die Funkverbindung neu aufgebaut werden kann Werden z B nur die Batterien im Außensensor ausgetauscht kann das Signal gar nicht oder nicht korrekt empfangen werden Beachten Sie dass die tatsächliche Reichweite von den jeweils verwendeten Baumaterialien der Gebäude sowie der jeweiligen Position der Basiseinheit und des Außensensors abhängt Durch ...

Page 19: ...station VERWENDUNG VON STANDFUSS ODER WANDAUFHÄNGUNG Hauptgerät und Außensensor können mit dem Standfuß ausklappbar 18 24 sowohl auf einer ebenen Fläche Tisch aufgestellt als auch mittels Aufhängevorrichtung 17 22 an der Wand montiert werden BEDIENUNG Empfang der Messwerte Sobald Sie die Batterien in den Außensensor eingelegt haben startet dieser mit der Übertragung der Messwerte in Intervallen vo...

Page 20: ...chseln 6 MEM oder CH drücken um den 24 oder 12 Stunden Modus einzustellen 7 AL SET drücken um zur nächsten Einstellung zu wechseln 8 MEM oder CH drücken um die Stunden für die aktuelle Uhrzeit einzustellen 9 AL SET drücken um zur nächsten Einstellung zu wechseln 10 MEM oder CH drücken um die Minuten für die aktuelle Uhrzeit einzustellen 11 AL SET drücken um zur nächsten Einstellung zu wechseln 12 ...

Page 21: ...HT Taste 16 drücken wenn der Wecker ertönt um den Wecker zu unterbrechen Das Symbol blinkt und der Wecker ertönt erneut nach 5 Minuten AL SET drücken um den Wecker bis zum nächsten Tag zu deaktivieren Temperatur und Luftfeuchtigkeit 1 Drücken Sie das Touch Bedienfeld C F SET 7b im Display um zwischen der Anzeige in C oder F zu wechseln Die Anzeige wechselt sowohl für die Außen als auch für die Inn...

Page 22: ...re Einstellungen Klimaveränderung Das Gerät berechnet aus den Messdaten die absolute Feuchtigkeit Die Symbole zeigen an wie sich das Lüften auf das Raumklima auswirken würde Feuchter Zu erwartende Erhöhung der Luftfeuchtigkeit um 5 oder mehr Gleichbleibend Zu erwartende Erhöhung oder Verringerung der Luftfeuchtigkeit um maximal 4 Trockener Zu erwartende Verringerung der Luftfeuchtigkeit um 5 oder ...

Page 23: ...hadstoffen und anderen flüchtigen Verbindungen in der Raumluft bei Luftfeuchtigkeits Komfortlevel Umgebungsveränderung Fenster öffnen Fenster schließen COMFORT TROCKENER FEUCHTER ODER KEINE VERÄNDERUNG off off DRY KEINE VERÄNDERUNG off off DRY Feuchter on off DRY Trockener off on WET Keine Veränderung off off WET Feuchter off on WET Trockener on off Signalprüfung am Hauptgerät durchführen Der Über...

Page 24: ...instellung am Hauptgerät 1 Mit dem Hauptgerät können bis zu 3 Außensensoren verbunden werden 2 Drücken Sie das Touch Bedienfeld CH 10c um zwischen den Anzeigen der einzelnen Kanäle zu wechseln Das Hauptgerät zeigt dann die Informationen des jeweiligen Außensensors an Erscheint das Symbol neben der Kanalinformation ist die automatische Anzeigenrotation aktiviert Die Anzeige wechselt dann im Abstand...

Page 25: ...efinden sich innerhalb des Empfangsbereichs und der Empfangsbereich ist frei von Störquellen und Hindernissen Verringern Sie gegebenenfalls die Entfernung zwischen den Geräten Verbindungsstörung Funksignale anderer Haushaltsgeräte wie Türklingeln Sicherheits und Eingangskontrollsystemen können störenden Einfluss auf dieses Gerät nehmen und so vorübergehende Fehlfunktionen verursachen Das ist völli...

Page 26: ...rfen Sie Elektrogeräte nicht in den Hausmüll Gemäß der Europäischen Richtlinie 2002 96 EG über Elektro und Elektronik Altgeräte und deren Umsetzung in nationales Recht müssen verbrauchte Elektrogeräte getrennt gesammelt und einer umweltgerechten Wiederverwertung zugeführt werden Batterien und Akkus dürfen nicht im Hausmüll entsorgt werden Sie sind zur Rückgabe gebrauchter Batterien und Akkus geset...

Page 27: ...besuchen Sie unsere Website über nachfolgenden Link QR Code für verfügbare Versionen Alternativ können Sie uns auch eine E Mail an die Adresse manuals bresser de schicken Bitte geben Sie stets Ihren Namen Ihre genaue Adresse eine gültige Telefonnummer und E Mail Adresse sowie die Artikelnummer und bezeichnung an www bresser de P7007401 EG KONFORMITÄTSERKLÄRUNG Hiermit erklärt Bresser GmbH dass der...

Page 28: ...cal changes reserved Manual_7007401_RC Hygrometer_en de_BRESSER_v082019a www bresser de start bresser Bresser GmbH Gutenbergstr 2 DE 46414 Rhede Germany www bresser de service bresser de anual_7007401_RC Hygrometer_en de_BRESSER_v082019a indd 28 26 08 2019 08 12 27 ...

Reviews: