Attention:

In case of problem with connection between the main unit and remote control, you can perform joint 
encoding operation:

Turn the remote control off, and push the power switch of the main unit to level “O”.
Press and hold [8] encoding key of the main unit. While still holding it, push the power switch 
of the main unit to level “I” to turn it on. The blue LED indicator on the front of the main unit 
flashes.

1.

2.

3.

and 

Release [8] encoding key, and simultaneously press the

                                                                                                                     keys of the remote control
for 2-3 seconds.The remote control LCD lights up while the main unit’s blue LED indicator
turns off -- it means the encoding is successful (This step should be completed within 6
seconds). If unsuccessful, repeat from the start.

Please make sure that one main unit is corresponding to one remote controller. The operation of 
encoding joint with multiply remote controller to the main unit is prohibited.
Important: Make sure that only one device is paired with the remote control. Multiple pairing of remote 
control and main unit is strictly prohibited.

Push the power switch of the main unit to level “0”, then back to level “1”. Both the main unit 
and remote control should now be working.

5

Preparation

No damage on power charger
Battery power is sufficient 

1.
2.

Prior to use, check the integrity of the machine and accessories.

Summary of Contents for iDream3

Page 1: ...USER MANUAL iDream3 HEAD MASSAGER ...

Page 2: ...Thank you for purchasing BREO iDream3 Pleasereadthismanualcarefullybeforeusing theproduct andkeepitinasafeplaceforfuture reference ...

Page 3: ...Introduction Inside the Package Function Deployment Operation Precautions 3 3 Preparation 5 9 10 Contents 2 4 5 6 8 Troubleshooting 11 Technical Parameters 12 Storage 12 ...

Page 4: ... Introduction The iDream3 adopts air pressure vibration and hot compress massaging technology to massage the head and ocular regions It comes with built in relaxing music You can now enjoy wonderful music while massaging further relaxing your brain MainUnit Controller Manual Power Charger Earphones Batteries USB Cable ...

Page 5: ...ingKey USBPort SizeAdjustingKnob TightnessAdjustingKnob 1 2 3 4 5 6 7 8 9 10 11 PressureReductionValve DCPowerPort LCDScreen Fromtoptobottom Time AirPressure Vibration HotCompress Music OperatingButton Clockwise UpButton FunctionModeNext DownButton FunctionModePrevious Center OKButton Powerswitchprotectionkey PushleftorrighttoturnON OFF MUSTpushpowerswitchtoLevel O aftereachuse ...

Page 6: ... control LCD lights up while the main unit s blue LED indicator turns off it means the encoding is successful This step should be completed within 6 seconds If unsuccessful repeat from the start Please make sure that one main unit is corresponding to one remote controller The operation of encodingjointwithmultiplyremotecontrollertothemainunitisprohibited Important Makesurethatonlyonedeviceispaired...

Page 7: ...e main unit to Level O Keep the massager turned OFF whilecharging Chargingtimeisapproximately3 4hours If the massager is turned on while recharging all functions of the product will run normally The machine will automatically stop charging to prevent damage to the device Ifthepowerofthebatteryislowerthan3 2 0 1V themachinewillautomaticallyturn off If the LED indicator of the main unit flashes it me...

Page 8: ... the main unit to computer using the supplied USB cable Push the power protection key on the main unit to Level 1 Copy MP3 music to the device 1 2 3 Use the back dial to adjust the distance between head to establish the most comfortable fit and wear main unit Use the top dial in setting the distance above head 1 2 picture1 to Level I picture2 Wear Power On Music Downloading 7 ...

Page 9: ...fault circulatesamongpre recordedmusic Press Buttontogotothepreviousone Pressandhold Button Volumeup Pressandhold Button Volumedown Off On Press Buttontoturnoff onMusic Pressandhold Buttontoswitchoverbetweenbuilt inmusicandMP3 music AutomaticMode withoutremotecontrol 1 2 PowerON PushtheON OFFswitchonthemainunittoLevel I Picture2 Noneedofremotecontrol Themainunitstartsworkingafter8seconds Preset de...

Page 10: ...er is designed as a personal care product It is not for diagnosis treatment of any health disorder nor meant for commercialuse To clean wipe with aseptic cotton and alcohol Do not wash or immerse in water 1 2 3 4 5 6 7 8 9 10 This product is not a substitute for healthcare professionals advice and treatment In case of doubt or if necessary please consult your healthcare professional 13 12 11 This ...

Page 11: ...quency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio ommunications However there is no guarantee that interference will not occur in a will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is...

Page 12: ...pressure orvibration Lithiumbatteryofthemainunit islow Lithium battery of the main unitislow Rechargethemainunitatonce Remotecontrolbatteriesare low out Changebatteries Remotecontrolbatteriesarenot installedcorrectly Check if positive negative poles of batteriesarepositionedright Make sure the batteries are snug in place Rechargethemainunitatonce Power Switch Protection key isnotturnedon Pushthisk...

Page 13: ...Maintain good ventilation and keep away from direct sunlight and corrosive gases 1 2 3 Ideal Environment Temperature5 40 RelativeHumidity 80 MainUnit L282mm X W206mm X H254mm Controller L132mm X W44mm X H24mm Net Weight DC Power AtmosphericPressure 860hpa 1060hpa 1125g Dimension DC 4 5V Power 4 5W TechnicalParameters Storage 12 ...