INSTALLATION AND SETTING
Check all applicable plumbing and electrical codes before proceeding with the installation.
This will help to ensure that the system is installed in safe and suitable manner.
�
CAUTION: Do not mount the unit in the direct path of steam.
This can short circuit and permanently damage the unit.
�
WARNING: Before installing the device and before intervening in any way on the metering unit,
make sure that the power supply is disconnected.
2.1
Mounting the system
Apply the panel unit system with the brackets and
screws supplied
Determinea suitable location for the system
Using the bracket as a template, mark and drill holes
for bolting the system to the wall
Insert the anchors in the holes
Bolt the bracket in place (flat side against the wall with
holes on bottom) with the hardware provided
2.2
Plumbing
The following installation steps apply for the pump:
Picture 1
Suction Line - Assemble the foot filter to insert in the chemical tank (See picture 2). –
Insert the 4x6 mm (1/4" OD) PVC tube through the ceramic weight.
Connect the PVC tube on to the barbed fitting of the plastic filter.
Slide on the ceramic weight in order to secure the connection.
Slide the filter and the tube into the chemical container so that it reaches the bottom.
Connect the other side of the tube into the pump suction fitting
�
Periodically clean it from possible residues.
Picture 2
Delivery Line – Connect PVC tube to delivery side of pump. Connect other end to duck check valve or
injection fitting
.
The following components are included:
-
duck check valve in FPM:
Threads: 3/8” Standard
Drill bit size: 14 mm (9/16”)