Protection against foreign objects and weather

 

The protection type of this distribution box is IP44 according to DIN EN 60529 (VDE 0470-1) provided 
that the correct operating position is observed. See “Mounting and commissioning” section.

 

This means:

 

– Protected against solid foreign objects with a diameter of more than 1.0 mm, e. g. wire.

 

– Protection against water splashing from any direction. 
Not suitable for continuous exposure to water.

 

 

General safety instructions

 

Qualified electrician

 

Mounting, disassembly, installation, commissioning and servicing of the device may only be 
performed by a qualified electrician. The qualified electrician must meet and observe the

 

following requirements:

 

– Intended use of the device.

 

– Compliance with the installation and operating instructions.

 

– Knowledge and application of the relevant electrotechnical provisions (e. g. DIN VDE 0100 

Part 600, DIN VDE 0100 Part 410) as well as the country-specific provisions regarding the 
construction of electrotechnical systems.

 

– Knowledge and application of the general and specific safety and accident prevention regulations.

 

– Ability to recognise risks and prevent possible hazards.

 

– Handover of the installation and operating instruction to the operator/user of the device.

 

Operation/Use

 

– Safe use is only ensured if these instructions are fully observed.

 

– Read these instructions thoroughly prior to installation, commissioning or operation.

 

– The distribution box is to be properly installed, maintained and commissioned by qualified experts 

in compliance with the relevant laws, regulations and standards.

 

– Never cover the distribution box to prevent trapped heat and the resulting fire hazard.

 

– Keep easily flammable and explosive substances away from the distribution box.

 

– Protect the cables

 

• by pulling at the plug and not at the cable to disconnect the device,

 

• by preventing mechanical damage to the cables,

 

• by keeping them away from intense heat.

 

– Protect the housing from mechanical damage such as impacts or powerful blows.

 

– Never operate the distribution box if it is defective.

 

– Avoid tripping hazards.

 

 

Packaging and transport

 

Packaging

 

Packaging material is valuable raw material and can be reused. This is why packaging 
material should be recycled. If this is not possible, dispose of the packaging material according

 

to the applicable local regulations.

 

Transport

 

Check your delivery for completeness and damages. If you notice any trans port damage or if the 
delivery is incomplete, please notify your distributor immediately.

 

 
 
 
 
 
 

 

 

WV 4/16A IP44 · WV 4/32A IP44

 

13

 

Summary of Contents for WV 4/16 A IP44

Page 1: ... warning marks a possibly dangerous situation Non compliance can lead to fatal or severe injuries DISPOSAL Mandatory self declaration according to the WEEE directive on the disposal of equipment Intended use The distribution box is used as an indoor or outdoor power distributor for wall mounting or as a mobile distributor This product is designed for professional use Installation and permanent con...

Page 2: ...f the installation and operating instruction to the operator user of the device Operation Use Safe use is only ensured if these instructions are fully observed Read these instructions thoroughly prior to installation commissioning or operation The distribution box is to be properly installed maintained and commissioned by qualified experts in compliance with the relevant laws regulations and stand...

Page 3: ...h the hinged lids of the sockets opening upwards WARNING Connecting the device to a supply cable with insufficient cable cross section and or an insufficient upstream fuse could result in a fire which may cause injuries or lead to an overload and damage the device Please observe the information on the name plate DANGER Working at live parts may cause severe or fatal injuries De energize the supply...

Page 4: ...the mounting holes in the housing see fig B 11 With this type of mounting protection class II no longer applies without additional cover of the mounting screws in the housing dangerous voltage If you would like to maintain protection class II cover the mounting screws with suitable protective caps 280 116 250 Fig C Drilling dimensions 250 WV 4 16A IP44 WV 4 32A IP44 4x Ø5 5 2x Ø6 2x Ø10 27 4 292 2...

Page 5: ... housing screws fig B 10 using a suitable tool Swivel the top of the housing fig A 2 downwards Position the device at the wall aligning the mounting holes Insert the mounting screws through the mounting holes fig B 11 of the bottom of the housing fig A 1 and tighten them Check that the device is secure Close the top of the housing Tighten the housing screws Check the connection of the sockets Supp...

Reviews: