Power Jet-Light 4 x 36 W IP 54
Operating Manual
19
Status: 7201S-07-2007_K
Step
Activity
Disconnect the wire. For this purpose, detach the pull relief and press the wire button to the
wire block.
Pos.
Name
8
Wiring
19 Pull
relief
20 Wire
button
21 Wire
block
4
Detach the bush by rotating in the anti-clockwise pattern.
Pos.
Name
13 Casing
14
Bush including bending protection
5
6
Unscrew the old wiring.
7
WARNING:
Use only original accessory of the same type during replacing the wiring
and the same wiring length.
IMPORTANT:
The green / yellow earthing wire must always be 3 cm longer than both
the other wiring.
Retract the wiring.
8
Clamp the wiring in the wire block. For this purpose, press the wire button and push the
wiring in the wire block.
9
Bolt the bush.
10
Position the metal plate. Fasten the metal plate with the previously removed bolts.
11
Fit the reflector in the casing. Fasten it with the reflector bolts.
12
Mount the illuminant (See chapter replace illuminant step 4+5)
IMPORTANT:
Check all the bolted connections before the initial operation.
7 Cleaning
Pull the main plug before cleaning. Due to reasons of the electrical security, the device is to be cleaned
with a dry or damp cloth. Please do not use any sharp cleaning material or chemicals (solvents, petrol
etc) and no rough sponges. Never dip the working lamp in water.
8 Waste
Disposal
The product should not be disposed in normal domestic waste at the end of its lifetime. Please enquire
with your city or municipal administration on possibilities of environmentally compatible and appropriate
disposal of the device.