Breezaire WK1060 Installation Instructions Download Page 5

WK(L)06/02 PG  5

In situations where the ambient relative humidity is very low, the desired enclosure relative humidity may not be achieved
without adding moisture.  To add moisture to the enclosure only use slow, natural evaporation from a small porous water
container.  Do not use a humidifier.

Improper placement or installation may cause the unit's performance to be degraded

.  The warm air exhaust side

(Condenser Side) of the unit must have a constant supply of fresh air, less than 85°F.

  If the unit is exhausted into a

confined area with poor ventilation or duct work, it will not be able to reject the heat and moisture it is removing from the
enclosure and a malfunctioning unit will be suspected.  If an obstruction to the flow of fresh air into or from the cooling unit
(see Fig. 3) is stopped or restricted for any reason the unit could heat rather than cool the enclosure.

NOTE:

  Should this condition develop when using the Sentry III, the unit will turn off when the enclosure temperature rises

to approximately 75°F, the unit will not restart until the enclosure temperature is lowered to approximately 65°F or the unit
is disconnected and then re-connected to the power supply.  This feature is disabled for approximately 45 minutes after the
unit is connected or re-connected to a power supply to allow initial cooling of enclosure.

Proper sealing of the enclosure through the use of a vapor barrier and weather stripping cannot be over emphasized.  The
unit will not be able to maintain the proper conditions if fresh; moisture-laden air is constantly being introduced into an
improperly sealed enclosure.  Symptoms of this condition are; unit runs all the time with only a slight reduction in enclosure
temperature and/or water overflows from the unit.  One way of discovering gross air leaks is to stand inside the enclosure
with the lights off, allow your eyes to adapt to the dark and look for light showing through cracks in the walls or around the
door.  Also close the door on a piece of paper, if you can pull the paper through the door seal, it means air and moisture are
also entering into your enclosure.  Because of the temperature difference between the inside and outside, very small cracks
can allow large amounts of outside air into the enclosure.  Please be aware that moisture will pass through solid concrete,
brick, paint, paper and wood.  A newly constructed room may contain fresh wood, paint, concrete and other building
materials containing large amounts of moisture.  This condition can cause symptoms similar to a poorly sealed enclosure,
but will gradually go away.

EXCESS CONDENSATE DRAIN TUBE:

  Your unit is equipped with a 

Pull-down Drain tube

 to prevent condensate

overflow.  To temporarily drain excess amounts of condensate engage the drain tube and provide a receptacle or drain to
receive the excess condensate.

EXTENDING THE DRAIN TUBE:

  To extend and open the drain, use a pair of small pliers to grab the red plastic plug

and vinyl tubing.  Pull the plug and tubing down approximately 6 inches until it snaps into the locked position and the "Grey
Fitting" is visible through the drain hole (see Fig. 4).  Remove the bottom red plug.  Now the cooling unit will drain any
condensate that is standing above 1/4 inch deep in the base pan.

CLOSING THE DRAIN TUBE: 

 To close the drain tube, simply replace the "Red stopper" and push the vinyl tubing back

up into the bottom of the cooling unit.  This action extends the top of the tube above the water line preventing it from
draining.  

CAUTION:

  Do not push the entire length of tubing back up into the drain hole.

INSTALLING A DRAIN LINE:

  To extend the drain tube into a basement drain or container, acquire a length of vinyl

tubing with an inside diameter of 1/2 inch from a local hardware store.  Slip this larger piece of tubing over the Pull-down
drain tube.  

CAUTION:

  Always have the extended drain line running "down hill".  This is a gravity flow system.  If a

horizontal run is encountered, an air vent or condensate pump may be required to maintain drainage.

Do not drill or tap the drain hole. Doing so will result in rusting of the metal base and void the unit's warranty.

RED PLUG

CLEAR TUBING

EXTENDED DRAIN TUBE

VIEW

NON EXTENDED DRAIN

(TUBE LOCATION)

GREY OR RED

FITTING

Figure 4

Summary of Contents for WK1060

Page 1: ..._ INSTALLED BY ______________________________ DATE__________________ While great effort has been made to provide accurate guidelines BREEZAIRE cannot warrant its units to properly cool a particular enclosure Customers are cautioned that enclosure construction unit location and many other factors can affect the operation and performance of the unit Therefore the suitability of the unit for a specif...

Page 2: ...exterior walls and ceiling insulation value should be a minimum of R 19 There should be no glass doors and or windows F All joints door frames electrical outlets or switches and any pipes or vents which go through the enclosure should be sealed to prevent air and moisture leakage into the room Concrete and brick are not insulation or moisture barriers F Doors into the enclosure should be of minimu...

Page 3: ...ET button while momentarily pressing the COOLER or WARMER button When the SET button is pressed the readout will automatically change and display the current set point temperature Should the operation of the cooling unit be interrupted by a power outage or by raising the set point temperature while the unit is running the Sentry III s internal delay will be activated and the unit will not restart ...

Page 4: ...roperly attached to the unit see Fig 3 F Make a hole through the wall as illustrated in Fig 2 The dimensions of the hole should be approximately 1 4 inch larger than the width and height given in the specifications If the unit is to be installed above floor level construct a shelf as shown in Fig 3 This shelf must be capable of supporting the weight indicated in the specifications NOTE Insulation ...

Page 5: ...ll the paper through the door seal it means air and moisture are also entering into your enclosure Because of the temperature difference between the inside and outside very small cracks can allow large amounts of outside air into the enclosure Please be aware that moisture will pass through solid concrete brick paint paper and wood A newly constructed room may contain fresh wood paint concrete and...

Reviews: