Breezaire WK1060 Installation Instructions Download Page 2

WK(L)06/02 PG  2

INSTALLATION INSTRUCTIONS

FOR WK SERIES COOLING UNITS

The 

BREEZAIRE

 WK Series cooling units are designed to, when installed in a properly constructed enclosure, provide a

constant, selectable temperature between approximately 48°F and 63°F while reducing the excess relative humidity to the
proper 50% to 75%.  

BREEZAIRE

 cooling units are designed to lower the temperature, while removing 

only 

excessive

moisture.  In a properly constructed enclosure this process can raise the 

relative

 humidity.  The unit does not add moisture to

the enclosure.  The unit does not include a heating system and will not warm the enclosure.  The WK Series is not intended
to cool service cabinets, which are maintained at lower temperatures and opened or entered frequently.

The WK Model has a mechanical thermostat and its adjustments requires a 1/4" straight type screwdriver. Turning the
adjusting screw clockwise lowers the set point, counter-clockwise raises it.

The WKL Model has a digital electronic (Sentry III) thermostat that adds additional safety and convenience features:

F

 

Large, easy to read, green LED display.

F

 

Accurate, easy to adjust (no tools needed), readable set points with continuous reading of enclosure temperature or
displaying of set point when changing enclosure temperatures.

F

 

Power outage protection, which delays unit start up after power outages.

F

 

Blocked airflow protection, which shuts down unit and protects wine in case of high temperatures caused by
condenser blockage.

F

 

Controls temperature by enclosure air sensors or optional bottle probe.

ENCLOSURE CONSTRUCTION

To use the below SIZING GUIDE, the enclosure to be cooled must be built to the following minimum specifications.  If the
enclosure cannot be built to these minimum specifications, consult your 

BREEZAIRE

 dealer for assistance in choosing the

correct unit.  

BREEZAIRE

 

cooling units are not warranted to cool a specific enclosure.

All walls, floors and ceilings should have a vapor barrier.  This vapor barrier should be installed on the warm side of the
insulation.  All interior walls and floors should be lined with a minimum of R-11 insulation and exterior walls and ceiling
insulation value should be a minimum of R-19.  There should be no glass doors and/or windows.

F

 

All joints, door frames, electrical outlets or switches and any pipes or vents which go through the enclosure should be

sealed to prevent air and moisture leakage into the room.  Concrete and brick are not insulation or moisture barriers.

F

 

Doors into the enclosure should be of minimum size, insulated to R-11 and be tightly sealed with a high quality

weather stripping.  Be sure to seal the bottom of the door and behind the door frame's molding.

F

 

Enclosure lighting should be of low wattage, with a timer to insure lights are not left on when the enclosure is

unoccupied.  Recessed lighting should not be used, as they will allow outside air to enter the enclosure.

F

 

The ambient temperature surrounding the enclosure should not exceed the desired cellar's temperature by more than

25°F.  No enclosure wall should receive direct sunlight or strong wind.

F

 

This is a mechanical piece of equipment, it will make noise and produce heat on the warm side exterior condenser

grille (Fig. 3).  Remember, unit installation location is not only important inside the wine cellar, but just as important
is where the warm side exhaust air is being rejected.

F

 

Note:

 

 Glass doors and/or windows are not included in our calculations and should not be used in a wine enclosure.

SIZING GUIDE & SPECIFICATIONS

This guide to be used only for enclosures meeting the above construction requirements.

BREEZAIRE

 

Model

Enclosure Volume

Electrical

Dimensions (inches)

Weight

WK(L) 1060

140 cu.ft.

3 Amp

14.25W x 13.25H x 16.38D

45 lb.

WK(L) 2200

265 cu.ft.

4 Amp

14.25W x 13.25H x 16.38D

55 lb.

WK(L) 3000

650 cu.ft.

5 Amp

14.25W x 19.75H x 21.63D

76 lb.

WK(L) 4000

1000 cu.ft.

7 Amp

14.25W x 19.75H x 21.63D

81 lb.

WK(L) 6000

1500 cu.ft.

9.5 Amp

16.25W x 22.00H x 21.63D

101 lb.

WK(L) 8000

2000 cu.ft.

10 Amp

16.25W x 22.00H x 21.63D

101 lb.

Note:  All units are 115 Volt, 60 Hz.

INSTALLATION

Before installing the unit, inspect it again for any shipping damage.  Test the unit by placing it in a room where the
temperature is above 65°F.  Position the unit to allow cold air to flow from evaporator outlet. (See Fig. 1)  Plug the unit's
electrical cord into a properly grounded electrical outlet of adequate capacity (see unit specification for unit electrical
requirements).

Summary of Contents for WK1060

Page 1: ..._ INSTALLED BY ______________________________ DATE__________________ While great effort has been made to provide accurate guidelines BREEZAIRE cannot warrant its units to properly cool a particular enclosure Customers are cautioned that enclosure construction unit location and many other factors can affect the operation and performance of the unit Therefore the suitability of the unit for a specif...

Page 2: ...exterior walls and ceiling insulation value should be a minimum of R 19 There should be no glass doors and or windows F All joints door frames electrical outlets or switches and any pipes or vents which go through the enclosure should be sealed to prevent air and moisture leakage into the room Concrete and brick are not insulation or moisture barriers F Doors into the enclosure should be of minimu...

Page 3: ...ET button while momentarily pressing the COOLER or WARMER button When the SET button is pressed the readout will automatically change and display the current set point temperature Should the operation of the cooling unit be interrupted by a power outage or by raising the set point temperature while the unit is running the Sentry III s internal delay will be activated and the unit will not restart ...

Page 4: ...roperly attached to the unit see Fig 3 F Make a hole through the wall as illustrated in Fig 2 The dimensions of the hole should be approximately 1 4 inch larger than the width and height given in the specifications If the unit is to be installed above floor level construct a shelf as shown in Fig 3 This shelf must be capable of supporting the weight indicated in the specifications NOTE Insulation ...

Page 5: ...ll the paper through the door seal it means air and moisture are also entering into your enclosure Because of the temperature difference between the inside and outside very small cracks can allow large amounts of outside air into the enclosure Please be aware that moisture will pass through solid concrete brick paint paper and wood A newly constructed room may contain fresh wood paint concrete and...

Reviews: