WK SERIES

(USA ONLY)

--INSTALLATION INSTRUCTIONS--

Thank you for choosing a 

BREEZAIRE

 

cooling unit.  We believe our products are the best

on the market and will provide many years of trouble-free service.

Please take a few minutes and read this entire instruction before beginning the installation.

MODEL _____________________ SERIAL NUMBER ______________________

INSTALLED BY ______________________________ DATE__________________

While great effort has been made to provide accurate guidelines, 

BREEZAIRE

 cannot warrant its units to properly cool a particular

enclosure.  Customers are cautioned that enclosure construction, unit location and many other factors can affect the operation and

performance of the unit.  Therefore the suitability of the unit for a specific enclosure or application must be determined by the customer

and cannot be warranted by 

BREEZAIRE.

Before removing the cooling unit from the box, please inspect for damage, which might have occurred

during shipping.  If damage is found, notify the Freight Company immediately.

BREEZAIRE 

is not responsible for any damages during shipping.

Summary of Contents for WK1060

Page 1: ..._ INSTALLED BY ______________________________ DATE__________________ While great effort has been made to provide accurate guidelines BREEZAIRE cannot warrant its units to properly cool a particular enclosure Customers are cautioned that enclosure construction unit location and many other factors can affect the operation and performance of the unit Therefore the suitability of the unit for a specif...

Page 2: ...exterior walls and ceiling insulation value should be a minimum of R 19 There should be no glass doors and or windows F All joints door frames electrical outlets or switches and any pipes or vents which go through the enclosure should be sealed to prevent air and moisture leakage into the room Concrete and brick are not insulation or moisture barriers F Doors into the enclosure should be of minimu...

Page 3: ...ET button while momentarily pressing the COOLER or WARMER button When the SET button is pressed the readout will automatically change and display the current set point temperature Should the operation of the cooling unit be interrupted by a power outage or by raising the set point temperature while the unit is running the Sentry III s internal delay will be activated and the unit will not restart ...

Page 4: ...roperly attached to the unit see Fig 3 F Make a hole through the wall as illustrated in Fig 2 The dimensions of the hole should be approximately 1 4 inch larger than the width and height given in the specifications If the unit is to be installed above floor level construct a shelf as shown in Fig 3 This shelf must be capable of supporting the weight indicated in the specifications NOTE Insulation ...

Page 5: ...ll the paper through the door seal it means air and moisture are also entering into your enclosure Because of the temperature difference between the inside and outside very small cracks can allow large amounts of outside air into the enclosure Please be aware that moisture will pass through solid concrete brick paint paper and wood A newly constructed room may contain fresh wood paint concrete and...