background image

Volledige bedieningshandleiding A
© Bredenoord bv 2016

4

2

Safety measures and symbols

Every other use of the Fixed Light Tower than that described in this user manual, can lead to a dangerous
work ing situation, both for the Fixed Light Tower and user(s). Bredenoord bv refuses to accept responsibility for
any claim of damage or human harm which has occurred because of not following the instructions in this
manual or by lack  of care during use, installation, service, maintenance or repair of the Fixed Light Tower. It is
necessary, before usage, to read this user manual with care. Always follow the safety instructions! For
information regarding installation, maintenance or repair not included in this manual, please contact Bredenoord
bv.

2.1

Safety markings in the text

The safety markings in the text have the following meaning:

BEWARE!

If a comment has additional information, it’s drawing your attention to possible problems or dangers.

WARNING!

Indicates that you can (seriously) injure yourself if you do not carry out the procedures with care.

DANGER!

Indicates that your life is directly threatened if you do not carry out the procedures with care.

2.2

Safety instructions

Only start the machine when all safety measures have been observed.
The Fixed Light Tower is only permitted to be operated, serviced, maintained and connected by qualified
and adequately trained personnel that is authorized by the customer.
No maintenance, connection, commissioning, usage or other operation before consulting the manual.
Switch the genset safe before carrying out maintenance, repairs or other jobs.
Operate the generator only when all protective parts have been correctly installed (again).
Watch out for parts that are under voltage in the electric switchboard cabinets.
Watch out for possible hot part.
Avoid contact between body parts, hair, jewellery or clothes and rotating parts, for example the cooling fan
or the v-belts, otherwise you could become trapped or injured.
Keep the doors of the room and/or genset closed during operation because of cooling, noise and entry.
Keep open fires and other combustible elements away from the Fixed Light Tower. Also don´t install the
genset nearby flammable gasses.
Keep a powder fire extinguisher in the direct proximity of the Fixed Light Tower.
Avoid contact of diesel oil, grease or battery acid with electrical cables.
Be careful with batteries, very high currents will run when short-circuited. Batteries sometimes also contain
corrosive acid.
Apply appropriate (personal) safety measures when servicing the Fixed Light Tower.
Do not use the genset if your concentration is diminished for example by tiredness or alcohol
consumption.

2.3

Safety symbols on the genset

Warning stickers have been placed on places where protection is not practical. To warn for dangerous
situations the following safety symbols can be used on the genset:

Danger! You are close to a life-threatening voltage!

Summary of Contents for VLM R0323

Page 1: ...Apeldoorn Zutphensestraat 319 7325 WT Apeldoorn Tel 31 0 55 301 85 40 Fax 31 0 55 301 85 50 www bredenoord com rental bredenoord com 6 9 2016 Solid Light Tower VLM R0323 R0347 Bredenoord Aggregaten B V Zutpensestraat 319 7325 WT APELDOORN Tel 055 3018501 Fax 055 3018500 E mail info bredenoord com Internet www bredenoord com ...

Page 2: ...ble of content 1 3 Complete operation manual 2 4 Safety measures and symbols 4 2 1 Safety markings in the text 4 2 2 Safety instructions 4 2 3 Safety symbols on the genset 3 6 Start and stop 4 7 Installation VLM 5 8 Moving the VLM 6 9 Expiring of the warranty ...

Page 3: ...Volledige bedieningshandleiding A Bredenoord bv 2016 3 1 Complete operation manual Solid Light Tower VLM R0323 R0347 ...

Page 4: ...ely trained personnel that is authorized by the customer No maintenance connection commissioning usage or other operation before consulting the manual Switch the genset safe before carrying out maintenance repairs or other jobs Operate the generator only when all protective parts have been correctly installed again Watch out for parts that are under voltage in the electric switchboard cabinets Wat...

Page 5: ...eware ventilator This sticker refers to this manual BEWARE It is not permitted to make adjustments in the control panel other than by a qualified electrician In all other cases only allow the installation to be adjusted by an employee of Bredenoord When you make adjustments yourself or have adjustments made the firm Bredenoord is not in any way responsible for possible damage as a result of incorr...

Page 6: ...ide the tower out with the lever 3 A red line will indicate when the maximum length has been reached The lights can be switched on with their corresponding circuit breakers 4 Lights off Switch off the lights by switching their circuit breakers 4 Slide the tower down with the lever 3 Switch off the mainswitch 2 Remove the power cable from the input 1 ...

Page 7: ...ition and tighten the lights with the lever 1 Pull the blocking pin 2 loose to twist the light tower Turn the light tower in the desired position Lock the tower again with the blocking pin 2 Pull the pin 3 up and pull the stabilizer till pen 3 falls into it s corresponding hole Drop the stabilizer by turning the lever 4 and level the Light tower horizontal Ground the Light Tower with the earth stu...

Page 8: ...an be found in the technical data Moving by means of the lifting eye if applicable The Light Tower can be lifted by means of the lifting eye with a chain and a suitable crane Never attach the chain directly to the lifting eye due to damage but use a closable hook Lifting eye if applicable Use only approved lifting equipment and check the lifting eye and lifting equipment for damage Moving by means...

Page 9: ...r accessories are added to the Light Tower without written permission from the manufacturer The Light Tower is used for other purposes than intended by the manufacturer The Light Tower is not installed moved operated and or put into operation as described in this manual Modifications are being made without written permission from the manufacturer The use is in contrary with the instructions prescr...