background image

 
SPECIAL MOBIL HOME REQUIREMENTS

 

 
WARNING: DO NOT INSTALL IN A SLEEPING ROOM.

 

 
For installation in a mobile home, an outside source of combustion air must be used 
(See “

COMBUSTION AIR SUPPLY”

). 

 
The Breckwell Big E must be grounded to the steel chassis of the home with 8 Ga. copper wire using a serrated or star washer to penetrate 
paint or protective coating to ensure grounding. 
 
The Breckwell Big E must be securely fastened to the floor of the mobile home through the two holes in the rear of the stove using 2, ¼” lag 
bolts that are long enough to go through both a hearth pad, if used, and the floor of the home. (See figure 11) 
 
Refer to “

VENTING

” for proper exhaust configurations. 

 

CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND 
CEILING/ROOF MUST BE MAINTAINED.

 

 

OPERATION 

10 

FIGURE 11 

Bolt Hole 

Bolt Hole 

Summary of Contents for Big E SP1000PB

Page 1: ...For your safety follow the installation directions Contact local building or fire officials about restrictions and installation inspection requirements in your area PLEASE read this entire manual bef...

Page 2: ...hich is designed for connection to an outside combustion air source The stove will not operate using natural draft or without a power source for the blower systems and fuel feed system and must not be...

Page 3: ...out air conditioning or in an area where direct sunlight can shine on the unit it is possible this can cause the temperature of the stove to rise to operational levels one of the sensors could then ma...

Page 4: ...g Door 12 Room Air Fan 12 Re Starting a Warm Stove 13 If Stove Runs Out Of Pellets 13 Refueling 13 Breckwell Maintenance Tool 13 Shutdown Procedure 13 Safety Features 13 Optional Thermostat 14 Thermos...

Page 5: ...t be placed on a continuous grouted joints noncombustible material such as ceramic tile cement board brick 3 8 millboard or equivalent or other approved or listed material suited for floor protection...

Page 6: ...d the stove WHEN OUTSIDE AIR IS NOT USED If outside air is not used it is important that combustion air is easily available to the air inlet A closeable outside air register can be used in tightly ins...

Page 7: ...ent refer to figure 3 3 Always maintain 3 clearance from combustible materials 4 Install L Vent wall thimble per L Vent manufacturer s instructions 5 Attach enough piping to penetrate and extend at le...

Page 8: ...ester C VERTICALLY INTO EXISTING CHIMNEY SYSTEM Adapters are available to adapt from 3 L Vent to 6 or 8 Class A chimney Figure 7 As an alternative 3 or 4 L Vent can be run inside existing chimney to t...

Page 9: ...nnect the horizontal pipe by pushing it through the hole in the masonry and lining it up with the branch in the tee Push the pipe into the tee while twisting it to lock it into the tee 7 If desired on...

Page 10: ...sher to penetrate paint or protective coating to ensure grounding The Breckwell Big E must be securely fastened to the floor of the mobile home through the two holes in the rear of the stove using 2 l...

Page 11: ...n to its original setting based on the Heat Level Advance setting d RESET TRIM Different size and quality pellet fuel may require adjustment of the 1 feed setting on the Heat Level Advance bar graph T...

Page 12: ...eckwell approved burnpot NOTE During the first few fires your stove will emit an odor as the high temperature paint cures or becomes seasoned to the metal Maintaining smaller fires will minimize this...

Page 13: ...om of the hopper b Scrape ashes from burnpot SHUTDOWN PROCEDURE Turning your Breckwell stove off is a matter of pressing the On Off control panel switch The red light will go out The blowers will cont...

Page 14: ...tion of this owner s manual HIGH LOW THERMOSTAT MODE When engaged in this mode the stove will automatically switch between two settings When warm enough it will switch to the 1 or low setting The room...

Page 15: ...switch on the control panel g KEEP ALL LOOSE OR MOVEABLE HOUSEHOLD COMBUSTIBLES SUCH AS FURNITURE DRAPES TOYS ETC AT LEAST THREE FEET FROM THE OPERATING STOVE h Maintain proper ventilation It is impor...

Page 16: ...ight up see Figure 16 d Empty ashes from the inner section and scrape with cleaning tool make sure holes are not plugged e Vacuum to remove ashes from the burn chamber interior and the burnpot shell W...

Page 17: ...LIAR WITH HOW ASHES AND CREOSOTE ACCUMULATE WITH YOUR OPERATING PRACTICES Use the small wire brush to also clean the inside of the chamber walls above the access doors BLOWERS DANGER RISK OF ELECTRIC...

Page 18: ...th a brush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professio...

Page 19: ...der the burnpot make sure the slider plate is in place to seal off the firebox floor 4 Vent pipe is incorrectly installed Check to make sure vent pipe installation meets criteria in owner s manual 5 T...

Page 20: ...the auger tube for signs of damage such as burrs rough spots or grooves cut into the metal that could have caused a jam 7 The auger motor has failed Remove the auger motor from the auger shaft and tr...

Page 21: ...r Check the voltage going to the igniter during startup It should be a full current If the voltage is lower than full current check the wiring If the wiring checks out good the board is bad SMOKE SMEL...

Page 22: ...e the auger shaft inspection plate in the hopper so that you can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing...

Page 23: ...ght at each setting after the stove has completed the startup cycle Make sure the times match the auger timing chart If the auger motor runs constantly the board is bad 8 Combustion blower is not spin...

Page 24: ...being used and what setting No other types of fuel have been approved for Breckwell pellet stoves If there are signs of other types of fuel being used advise the consumer to stop using them immediatel...

Page 25: ...FIGURE 21 ELECTRICAL DIAGRAM 25...

Page 26: ...Hose C M 340 T Auger Motor C E 017 Breckwell Maintenance Tool A TOOL 96 Burnpot A S BURNPOT Circuit Board Control Panel C E 401 Combustion Blower A E 027 Convection Blower A E 033 Door Gasket C G 050...

Page 27: ...fy the nearest Authorized Breckwell Dealer Provide your name address phone number serial number and model number of the stove date of purchase name and address of installer and as much information as...

Reviews: