5.0  

OPERATION

Operation of the valve is done by turning the handle a 1/4 turn 
(90 degree turn). Clockwise to close, counter clockwise to open.

5.1

Valve Open Position

The handle is parallel with the pipeline.

5.2

Valve in closed Position

The handle is perpendicular to the pipeline.

Valves with actuators should be checked for actuator-valve 
alignment. Misalignment will result in high operational torque and 
damage to valve stem and seals.

4.0  

GENERAL INFORMATION FOR ON-SITE INSTALLATION

The valve may be installed in any orientation on the pipeline and 
should be installed in the full open position 

Before installing the valves, the pipes must be flushed clean of 
dirt, burrs, and welding residues, or the seats and ball surface 
will be damaged. If for any reason the valve is installed prior to 
flushing of the piping system, the valve must remain in the full 
open position until the piping system has been fully flushed clean 
of debris.

For hydrostatic testing of the piping system, the valves must be 
placed in the half open position prior to pressurizing the system.  
If the valve is installed in a dead-end position on the piping, the 
valve must be placed in the half open position and equipped with 
a blind flange prior to pressurizing the system. 

NOTICE
Hydrostatic system testing with the valve in the closed position 
may result in damage to the valve seats, affecting their ability 
to create a proper seal. 

Failure to implement the installation and 

testing instructions as outlined, resulting in a valve failure, will 
void the warranty coverage of the product.  

Summary of Contents for FLOW-TEK Series

Page 1: ...FLOW TEK SERIES RF15 RF30 ONE PIECE FLANGED BALL VALVES Installation Operation and Maintenance Manual BRAY COM THE HIGH PERFORMANCE COMPANY...

Page 2: ...violate its proprietary nature without the express written permission of Bray International Inc TABLE OF CONTENTS 1 0 Definition of Terms 3 2 0 Design 4 3 0 Use 4 4 0 General Information for On Site...

Page 3: ...f your Bray valve Please understand the following examples of information used throughout this manual DANGER Indicates a potentially hazardous situation which if not avoided will result in death or se...

Page 4: ...the pressurized side of a closed valve must carry the load exerted by the line pressure on the ball while the upstream seat is subject to little load or wear For this reason it is sometimes possible t...

Page 5: ...alve may be installed in any orientation on the pipeline and should be installed in the full open position Before installing the valves the pipes must be flushed clean of dirt burrs and welding residu...

Page 6: ...15 18 19 26 26 1 5 11B 12 10 5 6 2 4 3 4 1 2 Valves Item Name 1 Body 2 End Cap 3 Ball 4 Seat 5 Seat Support 6 Body Seal 10 Anti Static Device 11A Packing Protector 11B Washer Protector 12 Thrust Wash...

Page 7: ...VED BRAY COM The Information contained herein shall not be copied transferred conveyed or displayed in any manner that would violate its proprietary nature without the express written permission of Br...

Page 8: ...d and drains are open monitored during installation 3 Before working on valve being in service make sure that service media has been flushed and line is safe Make sure that all applicable MSDS sheets...

Page 9: ...main in the original shipping container and be placed on pallets of wood or other suitable materials End protectors should remain on the valve ends to prevent the entrance of dirt and removed only at...

Page 10: ...off 1 4 turn secure lock washer tab For sizes larger than 2 simply tighten gland bolts evenly until leak stops Do not over tighten See Table 1 for Recommended Gland Nut Torque WARNING DO NOT remove p...

Page 11: ...alve should be cycled to assure there is no pressure trapped in valve cavity Ball valves can trap pressurized media when closed Flush line with valve in the half open position to remove hazardous medi...

Page 12: ...n handle to CLOSED position so that the stem tang and ball slot are in line with the port opening Lift or roll ball out of insert end NOTE Extreme caution should be taken to avoid damage to the ball I...

Page 13: ...out in a metal to metal fit Cycle the valve slowly with a gentle back and forth motion to build gradually to the full quarter turn By cycling slowly the seat lips will assure a permanent seal shape a...

Page 14: ...All statements technical information and recommendations in this bulletin are for general use only Consult Bray representatives or factory for the specific requirements and material selection for you...

Reviews: