background image

 

- 4 - 

Connecting to an LPG cylinder: 

Only use approved gas pressure regulator (regulated to 2.75kPa). Note: Pressure regulator is not supplied. 
The gas inlet on this fridge is ¼” BSP Parallel or ¼” BSP Union.    The thread required is RH ¼” BSP. 
The appliance cannot operate at a pressure other than the one specified.   
 
During connection of the fridge to the gas cylinder, always stay clear of any sort of ignition and do not smoke.   
Connect in the order; gas cylinder – pressure regulator – appliance.     
Excessive twisting and bending of the flexible hose must be avoided.     
 
The gas valve knob (right) is a combination of temperature control and ignition.    Furthermore the gas valve 
assembly consists of an incorporated safety pilot, a burner with an ignition plug and a piezo-electric igniter.   
The safety pilot automatically maintains the gas supply as long as it remains lit.    It automatically shuts off the 
supply of gas if the flame goes out. 
 

Leak Test: 

Open the gas valve of the gas cylinder.    Once the gas connections have been sufficiently tightened, use a 
soapy water solution to check connections for gas leaks.    There are no leaks if no bubbles form.    Never check 
for leaks using a flame.     
 

Starting your fridge on LPG:   

Press and hold down the gas control knob on the control panel, wait approx 15 seconds to prime the gas (this 
allows the gas to bleed through the burner), with the control knob still pressed in, turn knob to the right until 
you hear the click of the piezo ignition.    Hold the knob pressed in this position and check if the burner is alight 
by checking that the needle on the pilot light gauge is in the green section, then release the knob. 
 
It might be possible that this priming operation has to be repeated a couple of times, especially if the appliance 
has not been used for a long time or if the gas cylinder has been changed.    There can be air in the system, 
which has to be forced out.    You may also check that the pilot is lit by looking through the viewing port hole 
located at the rear bottom left hand corner of the fridge. 
If the flame fails to light, wait at least a minute before trying again.   
 
If the needle moves out of the green area this would indicate gas flow has stopped and the pilot light has gone 
out. If this should occur, follow the instructions to relight the unit. 
 
Leave the knob for some time in max position; after a sufficiently long cool down period, a lower position can be 
selected. 
 

Turning off the fridge off:   

When changing the gas cylinder or disconnecting the hose, it is necessary to close the valve of the gas cylinder.     
 
To disconnect the fridge running on gas: close the valve of the gas cylinder and then turn the gas valve knob in 
the panel to the ‘press’ position. 
 
 

 

 

When using LPG ensure fridge is in a well-ventilated area, where fresh air is circulating. 

 

Position the gas cylinder so that the hose is not kinked or stretched. 
 

 

Summary of Contents for XC-62GAS

Page 1: ... INSTRUCTION BOOKLET DO NOT STORE CHEMICALS OR FLAMMABLE MATERIALS OR SPRAY AEROSOLS NEAR THIS APPLIANCE DO NOT OPERATE THIS APPLIANCE USING LPG IN VEHICLES BOATS OR ENCLOSED AREAS Keep this Instruction Manual for future reference 3 WAY ABSORPTION UPRIGHT CAMPING FRIDGE MODEL NO XC 62GAS ...

Page 2: ...d bottles for storing products Ensure there is space around the contents for circulation of cold air Complying with the above will ensure efficient and economical cooling Make sure this fridge is in good working order before you use it Ensure only one source of energy is used at one time This appliance is not intended for use by persons including children with reduced physical sensory or mental ca...

Page 3: ...he polarity when starting up the appliance Verify the voltage of the battery with the voltage indicated on the technical data label at the back of the appliance When the appliance is powered by a motor vehicle battery only switch the fridge on while the vehicle engine is running When using a battery as a power source there is no thermostatically controlled temperature regulation Pre cool the fridg...

Page 4: ...d through the burner with the control knob still pressed in turn knob to the right until you hear the click of the piezo ignition Hold the knob pressed in this position and check if the burner is alight by checking that the needle on the pilot light gauge is in the green section then release the knob It might be possible that this priming operation has to be repeated a couple of times especially i...

Page 5: ... lead to serious injury or even death Always replace a damaged or porous hose Disposal If you wish to dispose of this fridge please contact your local authorities to ask for the correct way of disposal Troubleshooting If a problem occurs first carry out the following checks Is the appliance installed in a horizontal position Is there sufficient ventilation For 230v AC mains operation check the mai...

Page 6: ... 230 V 100 W 0 43 A Power Consumption 1 5 kWh 24h Gas General Product LPG Gas Pressure 2 75 kPa Gas Consumption 13g h Injector Size 0 22mm 0 02 Weight 21kg STM Group New Zealand Limited 16 Parkhead Place Albany North Shore 0632 PO Box 100 216 North Shore 0745 New Zealand Tel 64 9 9149400 Fax 64 9 9149410 Toll Free 0800 804646 sales stmgroup co nz www stmgroup co nz ...

Reviews: