Install Ports and Plugs

1. 

Install an O-ring (Ref. No. 30) on each of two plugs (Ref. No. 29). Thread 
one plug into fill port on discharge manifold (Ref. No. 24) and one plug 

into casing drain port.

2. 

Align  a  gasket  (Ref.  No.  26)  onto  discharge  flange  of  casing.  Install 
discharge  manifold  onto  casing  with  four  screws  (Ref.  No.  25). Torque 

screws to 100 in-lbs., alternate tightening screws in a cross pattern to 
eliminate crushing the gasket.

3. 

Align a gasket (Ref. No. 26) onto suction flange of casing. Install suction 
flange (Ref. No. 23) onto casing with four screws (Ref. No. 25). Torque 

screws to 100 in-lbs., alternate tightening screws in a cross pattern to 
eliminate crushing the gasket.

REPAIR AND MAINTENANCE INSTRUCTIONS

Shaft Seal Replacement

1. 

Loosen six screws (Ref. No. 27) until screw disengages square nut (Ref. 
No. 4) in bracket.

2.  Remove casing assembly from bracket.
3. 

Remove screws (Ref. No. 19) holding volute (Ref. No. 18) to bracket.

4.  Remove volute.
5. 

Remove impeller (Ref. No. 11).  Keyed shaft impellers; remove impeller 
screw (Ref. No. 15), inspect O-ring (Ref. No. 16) replace if required.

6.  Pry worn rotating half of shaft seal (Ref. No. 8) from impeller hub. Discard 

seal.

7. 

Remove screws (Ref. No. 6) holding bracket to engine, inspect O-rings 
(Ref. No. 7), replace if required.

8.  Remove bracket from engine.
9. 

Press stationary half of shaft seal (Ref. No. 8) from bracket. Discard seal.

10. 

Replace  any  O-rings  (Ref.  Nos.  17  &  20)  that  show  signs  of  wear  or 

damage.

11.  Rebuild pump with new shaft seal. Follow Pump End Assembly 

Instructions.

Cleaning Pump

1. 

Loosen six screws (Ref. No. 27) until screw disengages square nut (Ref. 
No. 4) in bracket.

2.  Remove casing assembly from bracket.
3. 

Remove screws (Ref. No.19) holding volute (Ref. No. 18) to bracket.

4.  Remove volute.
5.  Clean debris and sediment from inside of casing, volute, and impeller. 

Clean all volute passages and impeller vanes. Make sure closed impeller 
vane passages are clean by running a wire from impeller outside diameter 
to impeller eye. Remove any foreign objects clogging passages.

6.  Check all parts for excessive wear or damage. Replace parts as required.

7.  Reassemble pump.

Periodic Maintenance

1.  Clean outside of pump and engine to remove accumulated dirt, oil and 

grime.

2.  Maintain engine according to engine manufacturer’s recommendations.
3. 

It is recommended that a replacement shaft seal and seal kit be kept on 

hand at all times.

4.  Check for leaks during pump operation. Leaks may occur at shaft seal, 

casing to bracket connection, suction and discharge manifold connections, 

and through pump casing and bracket. Investigate and repair any leaks 

immediately. 

NOTE:

 Engine failure due to water intrusion into crankcase caused by a leaking 

seal will not be covered by engine or pump warranty.

5. 

Mechanical shaft seals are a wear item and require periodic replacement. 
Seal life is dependent on many factors including liquid pumped, sediment 

type, operating point, and suction conditions.

6.  Inspect for loose fasteners. Tighten any loose fasteners immediately.

Summary of Contents for BRP500TP2

Page 1: ... or damaged CAUTION For proper handling techniques and cautions when pumping certain chemicals contact your chemical supplier or local agencies fire dept etc CAUTION The engine is hot enough to cause injury do not touch the exterior of the engine especially the muffler and surrounding area WARNING Even though this unit will operate with minimal supervision it should not be left operating by itself...

Page 2: ...iquid surface and on a bed of rocks or other suitable surface If possible tie strainer up so it is suspended off pit bottom As a last resort tie the strainer in a large submerged bucket if bottom of water source is too soft or muddy Before Starting Engine 1 Fill engine crankcase with oil Follow engine manufacturer recommendations for service classification and viscosity of oil as detailed in engin...

Page 3: ...f the seal with soapy water Position in impeller hub bore with polished face out Protect polished face of the seal from damage with a piece of cardboard or cloth Press seal into bore until it bottoms 4 Install O ring Ref No 16 into bore in front of impeller nose Slide impeller screw Ref No 15 into through hole If required install shims inside impeller bore position on exposed screw end 5 Align key...

Page 4: ... bracket Discard seal 10 Replace any O rings Ref Nos 17 20 that show signs of wear or damage 11 Rebuild pump with new shaft seal Follow Pump End Assembly Instructions Cleaning Pump 1 Loosen six screws Ref No 27 until screw disengages square nut Ref No 4 in bracket 2 Remove casing assembly from bracket 3 Remove screws Ref No 19 holding volute Ref No 18 to bracket 4 Remove volute 5 Clean debris and ...

Page 5: ...ll a vacuum gauge on capped suction port Gauge to suction port connection must be 100 air tight 2 Fill pump casing completely with water 3 Run pump at full speed some water will be thrown out of discharge 4 Vacuum gauge should register 18 22 inches of mercury within a minute or so a If vacuum registers below 18 in of hg check gauge to pump connection for air leaks inspect replace volute impeller a...

Page 6: ...ption and number as shown in parts list Specifications Information and Repair Parts Manual IPT 2P5X 2S5X 3S5X x Please provide following information Model Number Serial Number if any Part Kit Description and Number NOTE Parts are available only in kits listed parts are not available individually For Repair Parts contact dealer where pump was purchased Figure 1 Repair Parts Illustration Figure 1 Re...

Page 7: ...Spacer N A Incl w Ref 11 Incl w Ref 11 1 13 Impeller Shim if required Incl w Ref 11 Incl w Ref 11 Incl w Ref 11 1 14 3 16 square x 1 2 long Key N A N A N A 1 15 5 16 24 Flat Head Screw N A N A N A 1 16 109 O Ring N A N A N A 1 17 167 O Ring P Series Incl w Ref 36 N A N A 1 160 O Ring S Series N A Incl w Ref 36 Incl w Ref 36 1 18 Volute Kit 2P5X 150 95 2S5X 150 95 3S5X 150 95 1 includes Ref Nos 18 ...

Page 8: ...120 IPT K0 1 35A Frame Hardware Kit If required Gas Engine 3120 105 95 3120 105 95 3120 105 95 1 36 EPDM O Ring Check Valve Gasket Kit 2PXE 300 90 2SXE 300 90 2SXE 300 90 1 includes Ref Nos 7 16 17 20 21 26 29 30 if required Viton Optional O Ring Check Valve Gasket Kit 2PXV 300 90 2SXV 300 90 2SXV 300 90 1 includes Ref Nos 7 8 16 17 20 21 26 29 30 if required 37 Adapter Gasket Incl w Ref 36 Incl w...

Page 9: ...hing eye protection etc in case of any malfunction For proper handling techniques and cautions contact your chemical supplier insurance company and local agencies fire dept etc Failure to comply with this warning could result in personal injury and or property damage 2 Make certain that the power source engine conforms to the requirements of your equipment 3 Provide adequate protection and guardin...

Page 10: ...ster pumping The foot valve should be installed when the suction lift is over 10 feet or when the suction line is over 10 feet long Engine Driven Centrifugal Pumps Operating Instructions Maintenance Manual 1808 633 00 2 6 2019 sure extinguisher is in operating condition check the pressure gauge or indicator Be familiar with its proper use Consult local fire department for the correct type of extin...

Page 11: ... running time to pick up a prime If pumping does not start within this time shut off the engine let unit cool down about 5 minutes refill pump casing and retry If engine does not start refer to Engine Manual If pump does not prime after two tries refer to Troubleshooting Chart in this manual 7 Properly fueled and lubricated the pump engine unit will run automati cally without attention to the cont...

Page 12: ...dential household use by a consumer Commercial use means all other uses including but not limited to use for commercial income producing or rental purposes or when purchased by a business This limited warranty applies to the original purchaser of the equipment verification of purchase in the form of a receipt is the responsibility of the buyer is non transferable and covers parts and labor Parts w...

Page 13: ...ull Name Last First M I Address Street Address Apartment Unit City State ZIP Code Home Phone Alternate Phone Email PURCHASED FROM Company Address Street Address Apartment Unit City State ZIP Code MODEL INFORMATION Purchase Date Application Type Homeowner Commercial Rental Model i e BRPT704H Serial i e 123456 Signature Register your product online at www braveproducts com ...

Page 14: ...Great Northern Equipment Distributuing Inc 20195 S Diamond Lake Rd Ste 100 Rogers MN 55374 Toll Free 800 350 8739 www braveproducts com sales braveproducts com ...

Reviews: