background image

   

Owner’s Manual

Brave Water Pump

 WARNING

Read and understand all instructions. 

Failure to follow all instructions may result in serious injury or property damage.

WARNING

: Wear appropriate protective gear. This list includes, but is not limited to: 

 

-safety glasses, protective boots with slip resistant soles, gloves, hearing protection.

• 

WARNING

: Keep guards in place and in working order. Never operate the product without the guards in place.

• 

WARNING

: LETHAL EXHAUST GAS! An internal combustion engine discharges carbon monoxide, which is a 

poisonous and odorless invisible gas. Death or serious illness may result if inhaled. Operate only in an area with 

good ventilation.

• 

DANGER

: Do not smoke when refueling. 

• 

WARNING

: Do not use pump in explosive atmosphere.

• 

WARNING

: Do not pump volatile or flammable liquids such as gasoline, fuel oil, kerosene, etc.

• 

CAUTION

: Do not attempt to operate pump, if any parts are missing or damaged. 

• 

CAUTION

: For proper handling techniques and cautions when pumping certain chemicals, contact your chemical 

supplier or local agencies (fire dept etc)

• 

CAUTION

: The engine is hot enough to cause injury, do not touch the exterior of the engine, especially the muffler 

and surrounding area.

• 

WARNING

: Even though this unit will operate with minimal supervision, it should not be left operating by itself. 

Depending on the application and area unit is operating (high traffic, people in area, etc.) will dictate the necessity 

of having someone watching over the unit.

• 

CAUTION

: Do not allow pump to be located in freezing or colder weather. Damage to pump will result.

• 

CAUTION

: Do not run pump dry, as permanent damage to the mechanical seal will result.

STOP!

ADD OIL TO ENGINE BEFORE USING: Engine is shipped without oil. DO NOT start engine without first adding oil. 

INSPECT COMPONENTS: Closely inspect to make sure no components are missing or damaged. 

Any Questions, Comments, Problems or Parts Orders

Call Brave Support 1-800-350-8739 

ITEM NUMBER(S):  BRP500TP2, BRP520TP3, BRP650HP2

MANUAL SERIAL TAG HERE

MBRP500TP2

Summary of Contents for BRP500TP2

Page 1: ... or damaged CAUTION For proper handling techniques and cautions when pumping certain chemicals contact your chemical supplier or local agencies fire dept etc CAUTION The engine is hot enough to cause injury do not touch the exterior of the engine especially the muffler and surrounding area WARNING Even though this unit will operate with minimal supervision it should not be left operating by itself...

Page 2: ...iquid surface and on a bed of rocks or other suitable surface If possible tie strainer up so it is suspended off pit bottom As a last resort tie the strainer in a large submerged bucket if bottom of water source is too soft or muddy Before Starting Engine 1 Fill engine crankcase with oil Follow engine manufacturer recommendations for service classification and viscosity of oil as detailed in engin...

Page 3: ...f the seal with soapy water Position in impeller hub bore with polished face out Protect polished face of the seal from damage with a piece of cardboard or cloth Press seal into bore until it bottoms 4 Install O ring Ref No 16 into bore in front of impeller nose Slide impeller screw Ref No 15 into through hole If required install shims inside impeller bore position on exposed screw end 5 Align key...

Page 4: ... bracket Discard seal 10 Replace any O rings Ref Nos 17 20 that show signs of wear or damage 11 Rebuild pump with new shaft seal Follow Pump End Assembly Instructions Cleaning Pump 1 Loosen six screws Ref No 27 until screw disengages square nut Ref No 4 in bracket 2 Remove casing assembly from bracket 3 Remove screws Ref No 19 holding volute Ref No 18 to bracket 4 Remove volute 5 Clean debris and ...

Page 5: ...ll a vacuum gauge on capped suction port Gauge to suction port connection must be 100 air tight 2 Fill pump casing completely with water 3 Run pump at full speed some water will be thrown out of discharge 4 Vacuum gauge should register 18 22 inches of mercury within a minute or so a If vacuum registers below 18 in of hg check gauge to pump connection for air leaks inspect replace volute impeller a...

Page 6: ...ption and number as shown in parts list Specifications Information and Repair Parts Manual IPT 2P5X 2S5X 3S5X x Please provide following information Model Number Serial Number if any Part Kit Description and Number NOTE Parts are available only in kits listed parts are not available individually For Repair Parts contact dealer where pump was purchased Figure 1 Repair Parts Illustration Figure 1 Re...

Page 7: ...Spacer N A Incl w Ref 11 Incl w Ref 11 1 13 Impeller Shim if required Incl w Ref 11 Incl w Ref 11 Incl w Ref 11 1 14 3 16 square x 1 2 long Key N A N A N A 1 15 5 16 24 Flat Head Screw N A N A N A 1 16 109 O Ring N A N A N A 1 17 167 O Ring P Series Incl w Ref 36 N A N A 1 160 O Ring S Series N A Incl w Ref 36 Incl w Ref 36 1 18 Volute Kit 2P5X 150 95 2S5X 150 95 3S5X 150 95 1 includes Ref Nos 18 ...

Page 8: ...120 IPT K0 1 35A Frame Hardware Kit If required Gas Engine 3120 105 95 3120 105 95 3120 105 95 1 36 EPDM O Ring Check Valve Gasket Kit 2PXE 300 90 2SXE 300 90 2SXE 300 90 1 includes Ref Nos 7 16 17 20 21 26 29 30 if required Viton Optional O Ring Check Valve Gasket Kit 2PXV 300 90 2SXV 300 90 2SXV 300 90 1 includes Ref Nos 7 8 16 17 20 21 26 29 30 if required 37 Adapter Gasket Incl w Ref 36 Incl w...

Page 9: ...hing eye protection etc in case of any malfunction For proper handling techniques and cautions contact your chemical supplier insurance company and local agencies fire dept etc Failure to comply with this warning could result in personal injury and or property damage 2 Make certain that the power source engine conforms to the requirements of your equipment 3 Provide adequate protection and guardin...

Page 10: ...ster pumping The foot valve should be installed when the suction lift is over 10 feet or when the suction line is over 10 feet long Engine Driven Centrifugal Pumps Operating Instructions Maintenance Manual 1808 633 00 2 6 2019 sure extinguisher is in operating condition check the pressure gauge or indicator Be familiar with its proper use Consult local fire department for the correct type of extin...

Page 11: ... running time to pick up a prime If pumping does not start within this time shut off the engine let unit cool down about 5 minutes refill pump casing and retry If engine does not start refer to Engine Manual If pump does not prime after two tries refer to Troubleshooting Chart in this manual 7 Properly fueled and lubricated the pump engine unit will run automati cally without attention to the cont...

Page 12: ...dential household use by a consumer Commercial use means all other uses including but not limited to use for commercial income producing or rental purposes or when purchased by a business This limited warranty applies to the original purchaser of the equipment verification of purchase in the form of a receipt is the responsibility of the buyer is non transferable and covers parts and labor Parts w...

Page 13: ...ull Name Last First M I Address Street Address Apartment Unit City State ZIP Code Home Phone Alternate Phone Email PURCHASED FROM Company Address Street Address Apartment Unit City State ZIP Code MODEL INFORMATION Purchase Date Application Type Homeowner Commercial Rental Model i e BRPT704H Serial i e 123456 Signature Register your product online at www braveproducts com ...

Page 14: ...Great Northern Equipment Distributuing Inc 20195 S Diamond Lake Rd Ste 100 Rogers MN 55374 Toll Free 800 350 8739 www braveproducts com sales braveproducts com ...

Reviews: