Maintenance and Storage
17
Pump Oil Change
1.)
Place a suitable container below the pump to catch the used oil, then, remove the oil fill cap and oil drain
plug.
2.)
Allow the used oil to drain completely, then reinstall the drain plug and tighten securely.
3.)
Please dispose of used oil in a manner that is compatible with the environment. We suggest you take used
oil in a sealed container to your local recycling center or service station for reclamation. Do not throw it in
the trash; pour it on the ground or down the drain.
4.)
With the pump in a level position, fill to the halfway point on the oil sight glass (see pump oil capacities
below). For Comet pumps use Universal Tractor Transmission Oil or Mobil 1 15W50 synthetic oil.
sight glass
drain plug
fill cap
Cat 3DNX25GSI Pump
fill cap
Comet BXD 1617E Pump
Oil capacity: 4.3oz. (.13L)
Oil capacity: 8.5 oz. (.25L)
FIG01854
Oil capacity: 8.5 oz. (.25L)
drain plug
sight glass
fill cap
Cat 2DX15ES Pump
drain plug
sight glass
Comet AXD 1617E Pump