USER MANUAL
5
9)
When finishing use, press “POWER” key about 2seconds to switch
off the power supply. When not use the unit in a long time, take
out the battery.
2.7.
Measuring The Tip Temperature
1)
Before measuring, clean the tip and then tin the tip thoroughly.
2)
Wet the tip with fresh solder then lay the tip on the measuring
point with the correct method as the following. For most tips, the
ideal angle is approximately 45 degrees. The temperature will
display 2 to 3 seconds. If the reading keeps changing, one of the
following conditions is likely to exist:
A. The tip is moving.
B. The sensor is about to expire.
C. There is too much airflow around
the tip.
Correct the situation and restart the measurement.
3)
If the solder accumulates on the sensor, remove it with a
desoldering tool or solder wick.
4)
Turn the power off when not in use