background image

Page 9

.6,)"(YDRAULICS0ARTS,IST

 

Item Qty. 

Description 

Part #

 

 

 

Pump Assembly (M-268-0112) 120G / 12V / Dual Relief  

30915-12V

 

Lead Wire Assembly, #6 Guage  

29049   

 

Clamp, Hose (M258) 

29663   

 

Diode Assembly, Up Solenoid 

73906A

 

Solenoid, 4-Post  (See Pump Module Exploded View for Solenoid Selection) 

 

 

 

Motor, Pump - 12 Volt - Low RPM 

29690   

 

Valve Assembly, “Dual Relief” (complete) 

31120K 

 

Cartridge (only), “Dual Relief” Valve - (shown below) 

31121 

 

Coil (only) - (shown below) 

31122   

  10 

Valve Assembly, “Down” (complete) 

31348K  

  11 

Cartridge (only), “Down” Valve - (shown below) 

26078   

  12 

Screw, 1/4-20 x 2-1/4”, Allen Head 

26080   

  13 

Hand Pump (Backup) with O-Rings (Item 11) 

26074   

  14 

O-Ring (only), Hand Pump Mounting 

17351   

  15 

Clamp, Reservoir - H-48 (M259) 

17069   

  16 

Reservoir, Hydraulic Fluid 

30160   

  17 

Cap, Reservoir Filler - Screw On 

30167   

  18 1  Fitting, 90° - 1/8” NPT x 1/8” Barb - Plastic 

87563

  19 

Connector, Plastic “Y”, 1/8” O.D. 

18877   

  20 

Hose, Thermal Plastic - Black, 1/8” I.D.  

23742R* (6”)

  21 

Handle with Grip 

17206A  

  22 

Fitting, Male 7-16-20 SAE O-Ring to Male 7/16-20 JIC 37° 

24504   

  23 

Elbow, 7/16-20 JIC 37 Female Swivel (1) - 7/16-20 JIC 37° Male (2) 

26579   

  24 

Hose Assembly, 1/8” (Opposite-Pump-Side) 

16004A-086 

  25 

Hose Assembly, 1/8” (Pump-Side) 

16004A-046 

  26 

Elbow, 90°, 7/16-20 SAE O-Ring Male - 7/16-20 JIC 37° Male, Ori

fi

ce 26667 

 

 

 27  2 

Cylinder 

 

C1514.3-9408 

  28 

Elbow, 90°, 1/4 NPT Male to 1/4” Barbed 

15150   

  29 

Hose, Thermal Plastic - Black, 1/8” I.D.  

23742R* (68”) 

  30 

Hose, Thermal Plastic - Black, 1/8” I.D. 

23742R* (30”)

  

Seal Kits:

  If repairing a cylinder, order Seal Kit #1500-0500

P

*   Raw material items ordered and priced per inch (order speci

fi

ed length).

8

Cartridge

#31121

9

Coil

#31122

“Dual Relief” Valve 

(complete)

7

11

Cartridge

#26078

9

Coil

#31122

“Down” Valve 

(complete)

10

Summary of Contents for NVL VISTA Series A2

Page 1: ...ccess to the World International Corporate Hdqrs P O Box 310 Winamac IN 46996 USA 1 800 THE LIFT 574 946 6153 FAX 574 946 4670 WARNING Read manual before installing or servicing lift Failure to do so...

Page 2: ...REGISTRATION CARDS MUST BE RETURNED TO THE BRAUN CORPORATION OWNER STATE ZIP Sample Warranty Registration Card 4WO RAUN 3ERIAL O 3ERIES O IDENTIlCATION TAGS SHOWN BELOW ARE POSTED ON THE LIFT NE TAG...

Page 3: ...al Schematic 4 Lift Wiring Diagram 5 Switch and Sensor Locations 6 LCD Error Codes 7 Hydraulics Hydraulic Schematic 8 Hydraulics Parts List 9 Hydraulics Diagram 10 Repair Parts Pump Module Pump Module...

Page 4: ...ns The platform will not fold stow when at least 50 pounds is on the platform 1 Position the platform at the floor level loading position 2 Loosen the locknut on the dual relief valve adjustment do no...

Page 5: ...r public lifts will activate if at least 25 pounds is on the threshold area when the platform is a least 1 below floor level 1 Remove the threshold warning plate 2 Verify the threshold strip switch co...

Page 6: ...FOLD 4 3 4 3 5 5 6 6 J21 8 9 P21 6 7 5 2 3 4 1 8 9 6 7 5 2 3 4 1 1 2 J9 1 2 P9 2 1 2 1 1 2 1 2 BK 20 BU 16 RD 20 WH 20 WH 20 PK 20 1 6 J8 1 6 P8 3 2 3 2 4 4 5 5 J6 GN 20 GN 20 RD 20 RD 20 BK 20 BK 18...

Page 7: ...3 3 0 1 3 8 1 K B 8 1 K B 8 1 K B 8 1 K B RD 20 BK 20 RD GN J6 J13 J5 E P13 BU 16 BU 16 WH BK Bridge Microswitch COM NO NC 30433A60 975 2543NA GREEN RED ORANGE GREEN RED BLACK 3 2 1 COLOR NO 3 COND WI...

Page 8: ...t 31664 Threshold Strip Switch 31221A Qty 2 Bridging Microswitch 975 0443RNA Rear Pump 975 0443FNA Front Pump IB Raised Magnetic Sensor 31030A45 IB Occupancy Microswitch Assy 31643A Rotary Position Se...

Page 9: ...s acti vated Flashing 76 Outboard barrier occupied switch is activated Flashing 78 Threshold tape switch A is activated Flashing 79 Threshold tape switch B is activated Flashing 80 Position set button...

Page 10: ...ding Relief Valve Lifting Relief Valve Fixed Displacement Pump Vented Reservoir Backup Pump Single Acting Cylinder Check Valve Manual Shutoff Valve 2 Way 2 Position Solenoid Valve Pressure Compensated...

Page 11: ...c Fluid 30160 17 1 Cap Reservoir Filler Screw On 30167 18 1 Fitting 90 1 8 NPT x 1 8 Barb Plastic 87563 19 1 Connector Plastic Y 1 8 O D 18877 20 1 Hose Thermal Plastic Black 1 8 I D 23742R 6 21 1 Han...

Page 12: ...Page 10 27 Opposite Pump Cylinder Manual Backup Pump 24 25 21 12 15 27 23 22 30 19 1 16 6 13 29 28 Hydraulic Pump Motor Pump Side Cylinder 10 7 17 20 18 28 26 26 14 2 3 5 4 6 YDRAULICS IAGRAM...

Page 13: ...t 5 16 18 x 3 4 Nylock Hex See note below 29608 38 2 Bolt 5 16 18 x 1 2 Nylock Hex See note below 10012 39 1 Cable Ground 22166A 40 1 Washer 5 16 External Tooth 16368 41 1 Beeper Continuous 30487 42 1...

Page 14: ...42 33 27 30 31 6 7 18 29 3 5 5 2 4 20 46 Pump Mounted Solenoid Backplate Mounted Solenoid OR 47 4 Pump Mounting Bolts Apply red 271 Thread Locker Locktite to the three pump mounting bolts items 37 and...

Page 15: ...uide 915 0703 115 3 Bearing UHMW Flat Thin Black 916 5406 116 2 Pivot Bridge Plate Lever Upper Inside 916 5433 117 4 Bearing Flange 3 4 x 1 2 24027 118 1 Weldment Latch Foot Rear 975 0204RNW 119 1 Wel...

Page 16: ...0 159 157 156 157 158 154 110 68 98 16 14 41 97 41 124 130 60 91 91 152 91 152 87 86 91 90 170 94 89 177 145 19 197 76 75 93 94 45 45 148 148 148 141 85 88 57 57 60 148 60 147 22 16 14 41 60 82 159 16...

Page 17: ...Over 300 Braun Dealers Worldwide Providing Access to the World Providing Access to the World International Corporate Hdqrs P O Box 310 Winamac IN 46996 USA 1 800 THE LIFT 574 946 6153 FAX 574 946 4670...

Page 18: ...information must be provided when filing a warranty claim or ordering parts Return Authorization Procedure The Braun Corporation of Winamac Indiana warrants that it will repair or replace at Braun s...

Reviews: