Temperature taking hints

Patients should stay in steady - state room condition for at least 30 minutes.

Hold the thermometer flush against the forehead and swipe slowly from above 
the eyebrow down to the temple, and back again.  Swiping too slow or too fast 
may impact your reading.

Do not remove the thermometer from the forehead before hearing the final beep.

Do not take a measurement while or immediately after nursing a baby.

Do not use the Forehead thermometer in high humidity environments.

Patients should not drink, eat, or be physically active before/while taking the 
measurement.

Before placing the thermometer sensor onto the forehead, remove dirt, hair, or 
sweat.

Use an alcohol swab to carefully clean the sensor and wait for 5 minutes before 
taking a measurement on another patient. Wiping the forehead with a warm 
or cool cloth may impact your reading. It is advised to wait 15 minutes before 
taking a reading.

5

read temperature

At the confirmation beep, remove the 
thermometer from the forehead and read the 
temperature. The screen will illuminate the 
appropriate color for the temperature 
reading. Green for normal temperatures, 
Yellow for slightly elevated temperatures, 
and Red indicates that fever may  
be present.

To repeat

Go to step 3.

6

To turn off

Press the power button. To conserve battery power, 
the unit will automatically shut down after 20 seconds 
of no use.

Calibration 

The thermometer is initially calibrated at the time of manufacture. If this 
thermometer is used according to the use instructions, periodic re-adjustment is 
not required. If at any time you question the accuracy of temperature 
measurements, please contact Consumer Relations.

Manufacturing date is given by the LOT number located inside the battery 
compartment. The first three (3) digits after LOT represent the Julian date that the 
product was manufactured and the next two (2) digits represent the last two 
numbers of the calendar year the product was manufactured. The last identifiers 
are the letters that represent the manufacturer. 

An example: LOT 11612, this product has been manufactured on the 116th day of 
the year 2012.

Always take the temperature in the same location, since the temperature 
readings may vary from different locations on the forehead.

In the following situations it is recommended that three temperatures in the 
same location be taken and the highest one taken as the reading:

  • Newborn infants in the first 100 days.
  •  Children under three years of age with a compromised immune system and 

for whom the presence or absence of fever is critical.

 • 

 When the user is learning how to use the thermometer for the first time 
until he/she has familiarized himself/herself with the instrument and obtains 
consistent readings.

Memory mode

The Braun Forehead thermometer includes a memory feature to recall the last 
temperature reading. The last temperature taken is stored in its memory and will 
be automatically displayed for 2 seconds when it is turned on.
 

Summary of Contents for FHT 1000

Page 1: ...is a registered trademark of Braun GmbH Kronberg Germany Cont ctenos Preguntas o Comentarios 1 800 327 7226 Correo electr nico consumerrelations kaz com Visite www kaz com braun Escriba a Consumer Re...

Page 2: ...ions when using on children Never immerse the Forehead thermometer into water or other liquids not waterproof For cleaning and disinfecting please follow the instructions in the Care and cleaning sect...

Page 3: ...hy use the Braun Forehead thermometer Measurement in under 3 seconds The innovative infrared technology allows measurement of forehead temperature in under 3 seconds Accurate and reliable Due to advan...

Page 4: ...wer button once Backlight will come on and the warm up sequence starts Ready When device displays STEADY 00 on the screen it s ready to take a measurement 3 Position Position the thermometer on the fo...

Page 5: ...use Calibration The thermometer is initially calibrated at the time of manufacture If this thermometer is used according to the use instructions periodic re adjustment is not required If at any time...

Page 6: ...ith positive and negative as shown Replace the battery door and close securely Replace the batteries when the flashing battery symbol appears on the LCD screen Dispose of batteries according to local...

Page 7: ...yrequirementsforthethermometeronlyinthedisplayrangeof96 8 Fto 102 2 F 36 Cto39 C forinfraredthermometersis 0 4 F 0 2 C whereasformercury in glass andelectronicthermometers therequirementperASTMStandar...

Page 8: ...r favor consulte a su m dico si observa s ntomas tales como irritabilidad inexplicable v mitos diarrea deshidrataci n cambios en el apetito o en la actividad convulsiones dolor muscular temblores rigi...

Page 9: ...orcionar n la mayor precisi n El term metro de Frente ha sido cl nicamente probado y demostrado para ser seguros y preciso cuando se usa de acuerdo con su manual de operaci n La temperatura normal es...

Page 10: ...os de toma de temperatura Los pacientes deben permanecer en una condici n constante en la habitaci n durante al menos 30 minutos Sostenga el term metro al ras de la frente y pase lentamente encima de...

Page 11: ...ca de memoria para recuperar la ltima lectura de temperatura La ltima temperatura tomada se almacena en su memoria y se mostrar autom ticamente durante 2 segundos cuando se vuelva a encender Errores y...

Page 12: ...o de no rayar la superficie de la pantalla colocando la tapa protectora despu s de cada uso Especificaciones del Producto Tipo Term metro de Frente FHT1000 Rango de medici n 93 2 F 108 F 34 C 42 2 C R...

Reviews: