Page 19
CONNECTOR - P1
(B.C.# 30136)
FROM VEHICLE GROUND
FROM POWER SOURCE - (25
AMP
. CURCUIT PROTECTION DEVICE)
FROM ST
OW SIGNAL
- (MOMENT
A
R
Y
CONT
ACT CONTROL
SWITCH)
FROM DEPLOY
SIGNAL
- (MOMENT
A
R
Y
CONT
ACT CONTROL
SWITCH)
D
A
G
E
F
C
B
H
DEPLOY SIGNAL (INPUT) - 14 GA.*
STOW SIGNAL (INPUT) - 14 GA.*
VEHICLE GROUND (INPUT) - 12 GA.*
POWER SOURCE (INPUT) - 12 GA.*
D
C
B
A
* RECOMMENDED WIRE GAUGE
FUNCTION / GAUGE
WIRING PROVIDED
BY INSTALLER
PIN
8-COND WIRE CODE
DEPLOYED INTERLOCK SIGNAL (OUTPUT) - 14 GA.*
STOWED INTERLOCK SIGNAL (OUTPUT) - 14 GA.*
PLUG - NOT USED
PLUG - NOT USED
H
G
F
E
Figure H
RAMP INSTALLATION
Positive (+) battery
lead wire must be
protected by
installer-provided 25
ampere fuse or
circuit breaker
.
Failure to do so may
result in serious
bodily injury and/or
property damage.
WARNING
8-pin Deutsch
Male Plug
(supplied with ramp)
8-pin Deutsch
Connector
(ramp equipped)
An 8-pin Deutsch connector (male
plug) is supplied with the ramp.
The ramp installer provides an ap-
propriate momentary contact control
switch.
Terminate the power supply, ground,
ramp OUT signal and ramp IN signal
as speci
fi
ed in legend.
The Positive (+) “battery” lead wire
must be protected by an in-line
25 ampere fuse or circuit breaker
(installer provided).
Electrical Connection Illustration
Summary of Contents for FF3248Y-24V
Page 29: ...Page 27 BLANK for LAYOUT...