Page 8
O
P
E
N
C
L
O
S
E
VALVE
2.
Position the lift platform ap-
proximately 12" above stow level
using the manual operation
system
. See Photo C.
Raising the platform will allow
access to the cam securement
screw and nut. See Photo E.
Inner Roll Stop Adjustment
CAUTION
Do not adjust inner
roll stop linkage rod.
Linkage rod adjust-
ment may result in
lift damage.
Do not adjust
inner roll stop
linkage rod at
this time!
Link-
age rod adjust-
ment is not
required unless
extra usable
platform length
is needed. If the
angle of the inner roll stop (when in the vertical
position) restricts the usable platform length
for the wheelchair passenger, adjustment of
the linkage rod will change the angle.
With the platform at ground level and the inner
roll stop in the vertical position, there should
be a minimum of 1" clearance between the in-
ner roll stop and torque tube. See photo I.
Adjust the inner roll stop as detailed in the
following procedures. Then, adjust the linkage
rod as detailed on page 9 (
only if necessary
).
Inner Roll Stop
Linkage Rod
1.
Raise the lift platform fully (
fl
oor level)
us-
ing the manual operation system
(Manual
Operating Instructions detailed on Quick
Reference Installation Sheet). If the inner
roll stop rests properly on the
fl
oor,
do not
adjust the inner roll stop. Lower the platform
to ground level. If the angle of the inner roll
stop (when in the vertical position), does not
restrict the usable platform length for the
wheelchair passenger,
disregard
inner roll
stop adjustment procedures. See Photo G
on page 9. Refer to the following procedures
if adjustment is required.
Stow Level
Platform
12
"
above
Stow
Level
B
C
Hand
Pump
Valve
Pump
Handle
Figure A
Manual Operation Systems
T-Handle
Release
Cable
Floor Level and Inner Roll Stop Adjustments