The heater must be electrically grounded in accordance with the following codes:
United States:
Refer to National Electrical Code
®
, ANSI/NFPA 70 (latest edition). Wiring must
conform to the latest edition of the National Electrical Code
®
, local ordinances, and
any special diagrams furnished.
Canada:
Refer to Canadian Electrical Code CSA C22.1 Part 1 (latest edition).
3.0
Installation
•
Electrical Requirements
•
Thermostat
Electrical Requirements
• 120 Volt - 60 Hz GRD, 3-wire.
• 120VAC thermostat connection.
• Starting current 1.5 amps.
• Running current 1.1 amps.
The 120V supply connection is factory wired with a three-prong pig tail.
Refer to Field Wiring Diagram (see Figure 3.22).
WARNING
!
Improper installation, adjustment, alteration, service or maintenance can cause property
damage, serious injury or death. Read and understand, the installation, operating and
maintenance instructions thoroughly before installing or servicing this equipment. Only
trained, qualified gas installation and service personnel may install or service this
equipment.
Not for residential use!
Do not use this heater in the home, sleeping quarters, attached
garages, etc. Installation of a commercial tube heater system in residential indoor spaces
may result in property damage, serious injury or death.
Thermostat
NOTE:
Different thermostats operate according to their particular features. Refer to thermostat
specifications for details.