MANUAL P/N 900000118 REV D
10
scenario, where the unit has been powered down for longer than 24 hours or has
been moved more than 60 miles since last use, it may take as long as 15 minutes to
acquire satellites and start displaying valid time.
A number of GPS parameters can be tracked on the Status page of the web-browser
interface. Select the Status tab at the top of the browser. The number of satellites
tracked as well as the position data from the GPS can be viewed.
As soon as 4 satellites are tracked, the front panel LED labeled “GPS Locked” will
light up.
4.2.3
HaveQuick Input
The HaveQuick reference requires both a standard HaveQuick II and a 1PPS input
signal, both conforming to ICD-GPS-060A. Connect the HaveQuick source to J5 and
the 1PPS source to J9. Ensure that HaveQuick is selected as reference on the web-
browser Setup page.
4.2.4
IRIG B Input
Connect a standard 1kHz modulated IRIG-B signal to the BNC connector at J7, and
ensure that IRIG-B is selected as reference input on the Setup page of the web-
browser.
4.2.5
1PPS
Connect a standard ICD-GPS-060 1PPS (1 pulse-per-second) signal to the J9
connector on the rear of the unit and ensure that “Ext 1PPS” is selected as reference
input on the Setup page of the web-browser.
Enter the date and time manually in the dialog boxes on the same web page and
click “submit” to allow the PTU to read those values.
4.2.6
Output Timing Signals
Regardless of the input reference selected, the PTU will always provide the
following output signals:
HaveQuick Out (J4)
Time-code Out (J6). IRIG B125 is the default settings.
1PPS Out (J8)
4.2.7
Front Panel Indications
The front panel shows a date/time display in years, days, hours, minutes and
seconds. The date and time displayed is derived from the currently selected
reference input, namely GPS, IRIG-B, HaveQuick or 1PPS. The display is also used to
display the IP address of the unit on power-up.
The front panel 7-segment time/ date display is turned off by default, to allow the
maximum battery life during the discharge cycle. To view the 7-segment display,
push and hold the “Display” button on the right-hand-side of the front panel.