14
A
DJUST
THE
RETARDER
ON
THE
TAPS
• Using a small
fl
at-head screwdriver,
screw in the brass burner-power screws
(yellow) all the way, (
fi
g. 1) screwing
them in a clockwise direction.
• Replace the gaskets and the knobs,
paying careful attention to their direction
and ensuring that the knobs are pushed
in all the way.
• Put the burner heads, covers and pan
supports back in position.
Appliance designed for installation in
SINGAPORE
LPG
Hourly input - see below at 15°C at 1013 mbar
G30
28/30 mbar
EXTRA
FAST
BURNER
Indicator marked on injector
88A
Nominal heat rating
(kW)
3.1
Low heat rating
(kW)
0.830
Hourly output
(g/h)
225
SEMI
FAST
BURNER
Indicator marked on injector
62
Nominal heat rating
(kW)
1.50
Low heat rating
(kW)
0.620
Hourly output
(g/h)
109
30
CM
HOB
2
GAS
RINGS
Total nominal heat rating
(kW)
4.6
Maximum output
(g/h)
334
MARK ON THE INJECTORS
This table shows the position
of the injectors on your hob
depending on the type of gas you
use. The number is marked on
each injector.
62
88A
LPG
●
Gas rating
Tap axis
Burner power
adjustment screw
Fig. 01
For Singapore : LPG Connection
The gasket depicted in the diagram on
the right is to prevent gas leakage. After
installation, turn on the gas supply and
use soap solution (never use naked
fl
ame) to check for gas leakage.
ring
nozzle
elbow joint
rubber hose
gasket